Production-hardening pass: half-open detection, cascade throttle, OBSERVE refresh, lamp/door coupling

Four failure modes observed in-house since the polling-first refactor
(709fdf4):

1. Half-open DTLS sessions where the socket stays writable but the peer
   has gone silent. Ping sends succeed against a wedged peer because
   RT-OCF doesn't reliably emit a RST; only successful polls prove the
   session is live.

   - PollScheduler exposes last_success_ts (bumped on every 2.05).
   - KeepaliveTask takes liveness_fn(); ticks fail if no 2.05 in the
     last 60s, even when the ping send succeeded.
   - Bridge force-closes the session after 120s unreachable so
     run_forever() breaks out of sess.join() and reconnects.

2. RT-OCF cascade under load. One wedged path can eat 8s of timeout,
   the next tier tick fires immediately and stacks another attempt,
   and the device wedges harder.

   - PollTier.timeout_s per-tier override (hot=2s, warm=4s, sweep=15s).
   - On TimeoutError, the href goes into a 5-60s cooldown via the
     existing _defer_until mechanism.
   - take_window_stats() now reports successful-poll RTT separately
     from a timeout count, exposed as the "Poll Timeouts (window)"
     diagnostic entity in HA.
   - Active-window throttle: if the previous health window saw >=3
     timeouts and is_active=True, drop back to idle cadence -- stops
     stacking polls on a stalled responder.

3. OBSERVE table aging across cloud-auth blips. The device stays
   DTLS-reachable but the on-device stack clears its observer table
   during the blip, so push delivery stays dead even after upstream
   recovers.

   - New ObserveRefreshTask per bridge; every 6h derregs all current
     observer tokens and re-subscribes on the existing session.

4. Oven lamp/door coupling. Oven hardware auto-drives the lamp from
   door state but /mode/vs/0 is warm-tier (30s) so HA showed stale lamp
   during a cook.

   - Track door + lamp value-change timestamps in descriptor_state.
     When the door transition is newer, derive lamp from door_open.
     When an HA optimistic write is newer, the cache value wins.

Also: ANSI-coloured WARNING/ERROR lines (NO_COLOR=1 opt-out), jittered
reconnect backoff so dryer + oven don't sync up after a router blip.

In-house verification: running on dryer + oven since 2026-06-03.
This commit is contained in:
Jack Nagy committed 2026-06-30 19:27:59 +01:00
1 parent 0374f8cf68
commit 36acf3a209
9 files changed
+438 -62

No files matched your search

+6
View File
@@ -439,11 +439,15 @@ def command_handlers():
# Empirical ceiling on this firmware is ~14 req/s (probe_poll_rate_combined.py
# 2026-06-03). The hot tier sits at 1s idle / 0.5s active — comfortably under
# the ceiling and leaves headroom for the warm + sweep budgets.
# Per-tier timeouts are scaled to cadence: hot tier retries every 1s, so
# a tight 2s ceiling caps the cascade damage from one wedged poll. Warm
# tier has more headroom; sweep is multi-block Block2 and tolerates ~15s.
DRYER_POLL_TIERS = [
PollTier(
name='hot',
interval_s=1.0,
active_interval_s=0.5,
timeout_s=2.0,
paths=(
('operational', 'state', 'vs', '0'),
),
@@ -451,6 +455,7 @@ DRYER_POLL_TIERS = [
PollTier(
name='warm',
interval_s=15.0,
timeout_s=4.0,
paths=(
('power', 'vs', '0'),
('kidslock', 'vs', '0'),
@@ -467,6 +472,7 @@ DRYER_POLL_TIERS = [
PollTier(
name='sweep',
interval_s=300.0,
timeout_s=15.0,
paths=(('device', '0'),),
is_sweep=True,
),