Initial commit

This commit is contained in:
Jack Nagy committed 2026-05-31 15:50:15 +01:00
commit c99ef324fc
20 files changed
+3774

No files matched your search

+665
View File
@@ -0,0 +1,665 @@
"""Oven descriptor (Samsung NV7000BS-class).
Resource map captured 2026-05-31 via DTLS-CoAP with the ab0b0ac4 cert.
See `local-tools/comparisons/oven-tree.md` for the full field reference.
Write surfaces this descriptor exposes:
proven:
* UpperLamp via /mode/vs/0 options RMW (probe_oven_lamp_toggle.py)
— works even with Remote Control off.
unproven (first HA use is also the test):
* Sound, FastPreheat — same RMW pattern as lamp.
* Setpoint via /temperatures/vs/0 items RMW. Mid-cook write may
or may not retune the element (plan §K-U #2).
* Mode select via /mode/vs/0 .modes — mid-cook acceptance unknown
(plan §K-U #3).
* Power on/off via /power/vs/0.
* Stop via /operational/state/vs/0 (dryer convention; oven may
use a different state value).
Untested writes are gated behind <prefix>/remote_available so HA
disables them in the UI when the oven's Remote Control switch is off."""
import time
from .base import (
ApplianceDescriptor,
avail_base,
avail_with_remote,
device_block,
encode,
)
# ---------------------------------------------------------------------
# OBSERVE paths — every push-eligible /<x>/vs/0 resource on the oven.
# Same wedge-safety story as the dryer: only `/<x>/vs/0` siblings push;
# OCF-standard `/<x>/0` paths accept registration but never fire.
# Security paths (/oic/sec/{doxm,pstat,acl,cred}) are deliberately
# EXCLUDED — those are the surfaces that nearly bricked the oven in
# prior sessions. The bridge has no reason to touch them.
# ---------------------------------------------------------------------
OBSERVE_PATHS = [
['operational', 'state', 'vs', '0'], # state, time, progress
['power', 'vs', '0'], # power On/Off
['oven', 'vs', '0'], # cavity state (Cooking, Idle, …)
['temperatures','vs', '0'], # current + desired temp
['doors', 'vs', '0'], # openState
['kidslock', 'vs', '0'], # child lock
['remotectrl', 'vs', '0'], # remote control enabled
['mode', 'vs', '0'], # cooking mode + options array
['alarms', 'vs', '0'], # alarm code (OV_E_OFF etc.)
['connected', 'vs', '0'], # cloud connectivity status
['otninformation', 'vs', '0'], # firmware-update flags
]
# ---------------------------------------------------------------------
# Mode dropdown — supportedModes minus the explicitly NotSupported one.
# Order matches the oven's own supportedModes list so the dropdown
# matches the device UI's order.
# ---------------------------------------------------------------------
SUPPORTED_MODES = [
'Autocook',
'Convection',
'TopHeatPluseConvection',
'Conventional',
'LargeGrill',
'SmallGrill',
'BottomHeatPluseConvection',
'PlateWarm',
'KeepWarm',
'Bottom',
'EcoConvection',
'FanGrill',
'Defrost',
# 'SteamClean', # control=NotSupported per modeSpec — exclude.
]
# Setpoint bounds — union across modeSpec entries on this oven. Per-mode
# bounds (e.g. PlateWarm 30–80) tighten this; the firmware will refuse
# out-of-range writes for the active mode and the HA UI will surface
# the resulting 4.xx in the bridge log.
SETPOINT_MIN_C = 30
SETPOINT_MAX_C = 270
SETPOINT_STEP_C = 5
# Samsung's operational state strings → OCF currentMachineState shape.
_SAMSUNG_STATE_TO_OCF = {
'Ready': 'idle',
'Run': 'active',
'Running': 'active',
'Pause': 'pause',
'Paused': 'pause',
'End': 'idle',
'Stop': 'idle',
}
def _num(v):
try: return float(v)
except (TypeError, ValueError): return None
def _int(v):
try: return int(v)
except (TypeError, ValueError): return None
def _option_value(options, prefix, default=None):
"""Find `<prefix>_<value>` in an options array and return <value>."""
for o in options:
if o.startswith(prefix + '_'):
return o.split('_', 1)[1]
return default
def _replace_in_options(options, prefix, new_value):
"""Return a new options array with any `<prefix>_*` entry replaced
by `<prefix>_<new_value>`. Caller must verify `options` is the live
options array first (Samsung uses replace-not-merge on this field)."""
return [f"{prefix}_{new_value}" if o.startswith(prefix + '_') else o
for o in options]
def _fmt_hms(seconds):
"""Format an integer second count as `H:MM:SS`. Returns None on
bad input so callers can leave the field null rather than emitting
a misleading `0:00:00`."""
try:
s = int(seconds)
except (TypeError, ValueError):
return None
if s < 0:
s = 0
h, rest = divmod(s, 3600)
m, sec = divmod(rest, 60)
return f"{h}:{m:02d}:{sec:02d}"
# ---------------------------------------------------------------------
# flatten — Samsung /device/0 links → HA-flavoured sensor dict.
# Every field reads from `/<x>/vs/0` paths so push updates immediately
# drive every entity. Where a field is settable (lamp, mode, setpoint),
# we publish it as a read-side sensor here AND as a writeable entity
# in build_discovery; the read side closes the HA UI feedback loop.
# ---------------------------------------------------------------------
def flatten(links):
g = lambda href, k, default=None: (links.get(href) or {}).get(k, default)
# Operational
sam_state = g('/operational/state/vs/0', 'x.com.samsung.da.state')
machine_state = (_SAMSUNG_STATE_TO_OCF.get(sam_state, sam_state)
if sam_state is not None else None)
operation_time = g('/operational/state/vs/0',
'x.com.samsung.da.operationTime')
remaining = g('/operational/state/vs/0',
'x.com.samsung.da.remainingTime')
rem_min = None
if remaining:
try:
h, m, s = remaining.split(':')
rem_min = int(h) * 60 + int(m) + (1 if int(s) > 0 else 0)
except Exception:
pass
# Cavity state — Cooking, Idle, Preheating, …
oven_state = g('/oven/vs/0', 'x.com.samsung.da.state')
# Temperatures
temps_items = (g('/temperatures/vs/0',
'x.com.samsung.da.items') or [])
cur_c = des_c = None
if temps_items:
cur_c = _int(temps_items[0].get('x.com.samsung.da.current'))
des_c = _int(temps_items[0].get('x.com.samsung.da.desired'))
# Door
doors_items = g('/doors/vs/0', 'x.com.samsung.da.items') or []
door = doors_items[0].get('x.com.samsung.da.openState') if doors_items else None
door_open = (door == 'Open') if door is not None else None
# Power
sam_power = g('/power/vs/0', 'x.com.samsung.da.power')
power_bin = (sam_power == 'On') if sam_power is not None else None
# Kidslock + Remote
sam_kids = g('/kidslock/vs/0', 'x.com.samsung.da.kidsLock')
kids_bin = (sam_kids != 'Ready') if sam_kids is not None else None
sam_rc = g('/remotectrl/vs/0',
'x.com.samsung.da.remoteControlEnabled')
rc_bin = (str(sam_rc).lower() == 'true') if sam_rc is not None else None
# Mode + options
modes = g('/mode/vs/0', 'x.com.samsung.da.modes') or []
current_mode = modes[0] if modes else None
options = g('/mode/vs/0', 'x.com.samsung.da.options') or []
lamp = _option_value(options, 'UpperLamp') # 'On' / 'Off'
sound = _option_value(options, 'Sound') # 'On' / 'Off'
fastpreheat = _option_value(options, 'fastpreheat') # 'On' / 'Off'
timer_state = _option_value(options, 'UpperTimerState') # 'Ready' / 'Running'
# UpperTimerCurrent/UpperTimerSet are integer seconds. Format as
# H:MM:SS for HA display so users see "1:10:00", not "4200".
timer_current_raw = _option_value(options, 'UpperTimerCurrent')
timer_set_raw = _option_value(options, 'UpperTimerSet')
timer_current = _fmt_hms(timer_current_raw)
timer_set = _fmt_hms(timer_set_raw)
timer_current_seconds = _int(timer_current_raw)
timer_set_seconds = _int(timer_set_raw)
# Alarms
alarm_items = g('/alarms/vs/0', 'x.com.samsung.da.items') or []
alarm_code = (alarm_items[0].get('x.com.samsung.da.code')
if alarm_items else None)
alarm_time = (alarm_items[0].get('x.com.samsung.da.triggeredTime')
if alarm_items else None)
# OV_E_OFF appears when the oven is off / no alarm; treat as inactive.
alarm_active = bool(alarm_code) and alarm_code != 'OV_E_OFF'
# Connectivity / firmware
sam_connected = g('/connected/vs/0', 'x.com.samsung.da.connected')
connected_bin = (sam_connected == 'On') if sam_connected is not None else None
fw_update_available = g('/otninformation/vs/0',
'x.com.samsung.da.newVersionAvailable')
fw_update_bin = (str(fw_update_available).lower() == 'true'
if fw_update_available is not None else None)
return {
'machine_state': machine_state,
'oven_state': oven_state,
'progress_percentage': _int(g('/operational/state/vs/0',
'x.com.samsung.da.progressPercentage')),
'operation_time': operation_time,
'completion_time': remaining,
'completion_minutes': rem_min,
'current_temp_c': cur_c,
'target_temp_c': des_c,
'door': door,
'door_open': door_open,
'power_state': sam_power,
'power_state_binary': power_bin,
'child_lock': sam_kids,
'child_lock_binary': kids_bin,
'remote_control': sam_rc,
'remote_control_binary': rc_bin,
'mode': current_mode,
'lamp': lamp,
'sound': sound,
'fastpreheat': fastpreheat,
'timer_state': timer_state,
'timer_current': timer_current,
'timer_set': timer_set,
'timer_current_seconds': timer_current_seconds,
'timer_set_seconds': timer_set_seconds,
'alarm_code': alarm_code,
'alarm_time': alarm_time,
'alarm_active': alarm_active,
'connected': sam_connected,
'connected_binary': connected_bin,
'firmware_update_available': fw_update_bin,
}
# ---------------------------------------------------------------------
# Remaining-time anchor + projection. The oven pushes /operational/state
# on state transitions but probably not on remainingTime ticks (matches
# dryer behaviour). Capture (ts, total_seconds) at each push and
# extrapolate downward while machine_state == active.
# ---------------------------------------------------------------------
def on_observation(state, href, rep):
if href != '/operational/state/vs/0':
return
rem = rep.get('x.com.samsung.da.remainingTime')
if not isinstance(rem, str):
return
try:
h, m, s = rem.split(':')
state['remaining_anchor'] = (time.time(),
int(h) * 3600 + int(m) * 60 + int(s))
except (ValueError, AttributeError):
pass
def project(state, sensors):
anchor = state.get('remaining_anchor')
if sensors.get('machine_state') != 'active' or anchor is None:
return sensors
ts, total = anchor
remaining = max(0, int(total - (time.time() - ts)))
h, rest = divmod(remaining, 3600)
m, s = divmod(rest, 60)
sensors = dict(sensors)
sensors['completion_time'] = f"{h}:{m:02d}:{s:02d}"
sensors['completion_minutes'] = h * 60 + m + (1 if s > 0 else 0)
return sensors
def log_state_change(sensors):
return (f"machine={sensors.get('machine_state')} "
f"oven={sensors.get('oven_state')} "
f"temp={sensors.get('current_temp_c')}/"
f"{sensors.get('target_temp_c')}°C "
f"mode={sensors.get('mode')}")
# ---------------------------------------------------------------------
# HA discovery inventory
# ---------------------------------------------------------------------
MODEL = 'OCF oven (TizenRT-iotivity, NV7000BS-class)'
# (key, friendly name, extra config)
#
# Only read-only sensors live here. Fields that ALSO have an
# interactive entity (light, switch, number, select) are removed —
# the interactive entity already surfaces the live state, so a
# duplicate read-only "Lamp state" / "Fast preheat state" / etc.
# sensor would just clutter the device card with the same value
# twice.
_SENSORS = [
('machine_state', 'Machine state', {'icon': 'mdi:stove'}),
('oven_state', 'Cavity state', {}),
('progress_percentage', 'Progress percent',
{'unit_of_measurement': '%', 'state_class': 'measurement'}),
('operation_time', 'Elapsed time', {'icon': 'mdi:timer'}),
('completion_time', 'Completion time', {'icon': 'mdi:timer-sand'}),
('completion_minutes', 'Remaining minutes',
{'unit_of_measurement': 'min', 'device_class': 'duration',
'state_class': 'measurement'}),
('current_temp_c', 'Temperature',
{'unit_of_measurement': '°C', 'device_class': 'temperature',
'state_class': 'measurement'}),
# target_temp_c is also exposed as a Number entity for editing,
# but the Number is RC-gated. The sensor stays always-visible so
# the user can see the current setpoint even with Remote Control
# off at the oven.
('target_temp_c', 'Setpoint',
{'unit_of_measurement': '°C', 'device_class': 'temperature',
'state_class': 'measurement', 'icon': 'mdi:thermometer-chevron-up'}),
# power_state: read-only. The oven doesn't expose a meaningful
# POST /power/vs/0 from cold — turning the unit on at the panel
# is a physical action — so we don't ship a Power switch entity.
('power_state', 'Power state', {'icon': 'mdi:power'}),
('door', 'Door state', {}),
('child_lock', 'Child lock state', {}),
('remote_control', 'Remote control state', {}),
('timer_state', 'Timer state', {}),
('timer_current', 'Timer remaining', {'icon': 'mdi:timer-sand'}),
('timer_set', 'Timer set', {'icon': 'mdi:timer'}),
('alarm_code', 'Alarm code',
{'icon': 'mdi:alert', 'entity_category': 'diagnostic'}),
('alarm_time', 'Alarm time',
{'icon': 'mdi:clock-alert', 'entity_category': 'diagnostic'}),
('connected', 'Cloud connectivity',
{'entity_category': 'diagnostic'}),
]
# (key, friendly, value_template, device_class, extras)
_BINARY_SENSORS = [
('running', 'Running',
"{{ 'ON' if value_json.machine_state == 'active' else 'OFF' }}",
'running', {}),
('door_open', 'Door',
"{{ 'ON' if value_json.door_open else 'OFF' }}",
'door', {}),
# `power_switch` binary_sensor would duplicate the Power switch
# entity below; the switch already shows on/off state.
('child_lock_active', 'Child lock',
"{{ 'ON' if value_json.child_lock_binary else 'OFF' }}",
'lock', {}),
('remote_control_enabled', 'Remote control',
"{{ 'ON' if value_json.remote_control_binary else 'OFF' }}",
'connectivity', {}),
('alarm_active', 'Alarm active',
"{{ 'ON' if value_json.alarm_active else 'OFF' }}",
'problem', {}),
('connected_bin', 'Connected',
"{{ 'ON' if value_json.connected_binary else 'OFF' }}",
'connectivity', {'entity_category': 'diagnostic'}),
('firmware_update_available', 'Firmware update available',
"{{ 'ON' if value_json.firmware_update_available else 'OFF' }}",
'update', {'entity_category': 'diagnostic'}),
]
# MQTT command-topic suffixes (under <prefix>/cmd/…)
CMD_LAMP = 'cmd/lamp'
CMD_SOUND = 'cmd/sound'
CMD_FASTPREHEAT = 'cmd/fastpreheat'
CMD_POWER = 'cmd/power'
CMD_STOP = 'cmd/stop'
CMD_MODE = 'cmd/mode'
CMD_SETPOINT = 'cmd/setpoint'
def build_discovery(topic_prefix, ha_prefix, device_name):
state_topic = f"{topic_prefix}/state"
avail_topic = f"{topic_prefix}/availability"
remote_topic = f"{topic_prefix}/remote_available"
dev = device_block(topic_prefix, device_name, MODEL)
out = []
# --- read-only sensors -------------------------------------------
for key, name, extra in _SENSORS:
cfg = {
'name': name,
'unique_id': f"{topic_prefix}_{key}",
'object_id': f"{topic_prefix}_{key}",
'state_topic': state_topic,
'value_template': f"{{{{ value_json.{key} }}}}",
'availability': avail_base(avail_topic),
'device': dev,
}
cfg.update(extra)
out.append((f"{ha_prefix}/sensor/{topic_prefix}/{key}/config",
encode(cfg)))
for key, name, template, dclass, extra in _BINARY_SENSORS:
cfg = {
'name': name,
'unique_id': f"{topic_prefix}_{key}",
'object_id': f"{topic_prefix}_{key}",
'state_topic': state_topic,
'value_template': template,
'payload_on': 'ON',
'payload_off': 'OFF',
'device_class': dclass,
'availability': avail_base(avail_topic),
'device': dev,
}
cfg.update(extra)
out.append((f"{ha_prefix}/binary_sensor/{topic_prefix}/{key}/config",
encode(cfg)))
# --- light: oven lamp (proven via probe_oven_lamp_states.py;
# binary On/Off only — High/Low/Dim coerce back to previous
# state. Works regardless of Remote Control switch, so we only
# gate on base availability). For the MQTT light default schema,
# state_value_template's output must match payload_on/payload_off
# exactly (case-sensitive) for HA to recognise the state.
cfg = {
'name': 'Lamp',
'unique_id': f"{topic_prefix}_lamp_light",
'object_id': f"{topic_prefix}_lamp_light",
'state_topic': state_topic,
'state_value_template': "{{ value_json.lamp }}",
'command_topic': f"{topic_prefix}/{CMD_LAMP}",
'payload_on': 'On',
'payload_off': 'Off',
'icon': 'mdi:track-light',
'availability': avail_base(avail_topic),
'device': dev,
}
out.append((f"{ha_prefix}/light/{topic_prefix}/lamp/config",
encode(cfg)))
# --- switches (RC-gated; untested mid-cook). Sound + fastpreheat
# are options-array writes (same RMW path as lamp); Power is a
# /power/vs/0 single-field write. --------------------------------
untested_switches = [
('sound', 'Sound', '{{ value_json.sound }}', CMD_SOUND, 'mdi:volume-high'),
('fastpreheat', 'Fast preheat', '{{ value_json.fastpreheat }}', CMD_FASTPREHEAT, 'mdi:fire'),
# Power deliberately omitted: turning the oven on at the
# cold-start panel is a physical action; the read-only
# power_state sensor (above) reflects its state.
]
for key, name, tpl, cmd, icon in untested_switches:
cfg = {
'name': name,
'unique_id': f"{topic_prefix}_{key}_switch",
'object_id': f"{topic_prefix}_{key}_switch",
'state_topic': state_topic,
'value_template': tpl,
'state_on': 'On',
'state_off': 'Off',
'command_topic': f"{topic_prefix}/{cmd}",
'payload_on': 'On',
'payload_off': 'Off',
'icon': icon,
'availability': avail_with_remote(avail_topic, remote_topic),
'availability_mode': 'all',
'device': dev,
}
out.append((f"{ha_prefix}/switch/{topic_prefix}/{key}/config",
encode(cfg)))
# --- number: setpoint (RC-gated, slider input) ------------------
cfg = {
'name': 'Setpoint',
'unique_id': f"{topic_prefix}_setpoint",
'object_id': f"{topic_prefix}_setpoint",
'state_topic': state_topic,
'value_template': '{{ value_json.target_temp_c }}',
'command_topic': f"{topic_prefix}/{CMD_SETPOINT}",
'min': SETPOINT_MIN_C,
'max': SETPOINT_MAX_C,
'step': SETPOINT_STEP_C,
'unit_of_measurement': '°C',
'device_class': 'temperature',
'mode': 'slider',
'icon': 'mdi:thermometer-chevron-up',
'availability': avail_with_remote(avail_topic, remote_topic),
'availability_mode': 'all',
'device': dev,
}
out.append((f"{ha_prefix}/number/{topic_prefix}/setpoint/config",
encode(cfg)))
# --- select: mode (RC-gated) ------------------------------------
cfg = {
'name': 'Cooking mode',
'unique_id': f"{topic_prefix}_mode_select",
'object_id': f"{topic_prefix}_mode_select",
'state_topic': state_topic,
'value_template': '{{ value_json.mode }}',
'command_topic': f"{topic_prefix}/{CMD_MODE}",
'options': SUPPORTED_MODES,
'icon': 'mdi:tune',
'availability': avail_with_remote(avail_topic, remote_topic),
'availability_mode': 'all',
'device': dev,
}
out.append((f"{ha_prefix}/select/{topic_prefix}/mode/config",
encode(cfg)))
# --- button: Stop cycle ----------------------------------------
# NOT gated on remote_available: the SmartThings app stops the
# oven regardless of the Remote Control switch state, so the
# device clearly honours Stop without that gate. Only requires
# the bridge itself to be online.
cfg = {
'name': 'Stop cycle',
'unique_id': f"{topic_prefix}_stop",
'object_id': f"{topic_prefix}_stop",
'command_topic': f"{topic_prefix}/{CMD_STOP}",
'payload_press': 'Stop',
'icon': 'mdi:stop',
'availability': avail_base(avail_topic),
'device': dev,
}
out.append((f"{ha_prefix}/button/{topic_prefix}/stop/config",
encode(cfg)))
return out
# ---------------------------------------------------------------------
# Command handlers — fn(payload, links) → (path_segs, body_dict) | None.
# Read-modify-write handlers (lamp/sound/fastpreheat) snapshot the
# `/mode/vs/0` options array and replace just their slot. /temperatures
# is also RMW because Samsung's write semantics on the items array are
# replace-not-merge.
# ---------------------------------------------------------------------
def _mode_options(links):
"""Return the live `/mode/vs/0` options array (a copy), or None
if /mode/vs/0 isn't seeded yet."""
rep = links.get('/mode/vs/0') or {}
opts = rep.get('x.com.samsung.da.options')
if not opts:
return None
return list(opts)
def _temps_items(links):
"""Return a deep-ish copy of the /temperatures/vs/0 items array."""
rep = links.get('/temperatures/vs/0') or {}
items = rep.get('x.com.samsung.da.items') or []
return [dict(it) for it in items] if items else None
def command_handlers():
def _lamp(p, links):
if p not in ('On', 'Off'):
return None
opts = _mode_options(links)
if opts is None:
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': _replace_in_options(opts, 'UpperLamp', p),
}
def _sound(p, links):
if p not in ('On', 'Off'):
return None
opts = _mode_options(links)
if opts is None:
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': _replace_in_options(opts, 'Sound', p),
}
def _fastpreheat(p, links):
if p not in ('On', 'Off'):
return None
opts = _mode_options(links)
if opts is None:
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': _replace_in_options(
opts, 'fastpreheat', p),
}
def _power(p, _links):
if p not in ('On', 'Off'):
return None
return ['power', 'vs', '0'], {'x.com.samsung.da.power': p}
def _stop(_p, _links):
# Untested for the oven. Dryer convention is state='Ready' to
# leave the cycle in idle. If this turns out to be wrong, the
# bridge will log the 4.xx but the oven won't be harmed —
# /operational/state/vs/0 isn't a wedge-trigger surface.
return ['operational', 'state', 'vs', '0'], {
'x.com.samsung.da.state': 'Ready',
}
def _mode(p, _links):
if p not in SUPPORTED_MODES:
return None
return ['mode', 'vs', '0'], {'x.com.samsung.da.modes': [p]}
def _setpoint(p, links):
try:
temp = float(p)
except (TypeError, ValueError):
return None
# Snap to step and bounds.
temp_i = int(round(temp / SETPOINT_STEP_C) * SETPOINT_STEP_C)
if not (SETPOINT_MIN_C <= temp_i <= SETPOINT_MAX_C):
return None
items = _temps_items(links)
if items is None:
return None
items[0]['x.com.samsung.da.desired'] = str(temp_i)
return ['temperatures', 'vs', '0'], {
'x.com.samsung.da.items': items,
}
return {
CMD_LAMP: _lamp,
CMD_SOUND: _sound,
CMD_FASTPREHEAT: _fastpreheat,
CMD_POWER: _power,
CMD_STOP: _stop,
CMD_MODE: _mode,
CMD_SETPOINT: _setpoint,
}
# ---------------------------------------------------------------------
OVEN = ApplianceDescriptor(
name='oven',
default_observe_port=49154,
observe_paths=OBSERVE_PATHS,
seed_path=['device', '0'],
flatten=flatten,
build_discovery=build_discovery,
command_handlers=command_handlers,
on_observation=on_observation,
project=project,
remote_available_field='remote_control_binary',
log_state_change=log_state_change,
)