Jack Nagy 36acf3a209 Production-hardening pass: half-open detection, cascade throttle, OBSERVE refresh, lamp/door coupling
Four failure modes observed in-house since the polling-first refactor
(709fdf4):

1. Half-open DTLS sessions where the socket stays writable but the peer
   has gone silent. Ping sends succeed against a wedged peer because
   RT-OCF doesn't reliably emit a RST; only successful polls prove the
   session is live.

   - PollScheduler exposes last_success_ts (bumped on every 2.05).
   - KeepaliveTask takes liveness_fn(); ticks fail if no 2.05 in the
     last 60s, even when the ping send succeeded.
   - Bridge force-closes the session after 120s unreachable so
     run_forever() breaks out of sess.join() and reconnects.

2. RT-OCF cascade under load. One wedged path can eat 8s of timeout,
   the next tier tick fires immediately and stacks another attempt,
   and the device wedges harder.

   - PollTier.timeout_s per-tier override (hot=2s, warm=4s, sweep=15s).
   - On TimeoutError, the href goes into a 5-60s cooldown via the
     existing _defer_until mechanism.
   - take_window_stats() now reports successful-poll RTT separately
     from a timeout count, exposed as the "Poll Timeouts (window)"
     diagnostic entity in HA.
   - Active-window throttle: if the previous health window saw >=3
     timeouts and is_active=True, drop back to idle cadence -- stops
     stacking polls on a stalled responder.

3. OBSERVE table aging across cloud-auth blips. The device stays
   DTLS-reachable but the on-device stack clears its observer table
   during the blip, so push delivery stays dead even after upstream
   recovers.

   - New ObserveRefreshTask per bridge; every 6h derregs all current
     observer tokens and re-subscribes on the existing session.

4. Oven lamp/door coupling. Oven hardware auto-drives the lamp from
   door state but /mode/vs/0 is warm-tier (30s) so HA showed stale lamp
   during a cook.

   - Track door + lamp value-change timestamps in descriptor_state.
     When the door transition is newer, derive lamp from door_open.
     When an HA optimistic write is newer, the cache value wins.

Also: ANSI-coloured WARNING/ERROR lines (NO_COLOR=1 opt-out), jittered
reconnect backoff so dryer + oven don't sync up after a router blip.

In-house verification: running on dryer + oven since 2026-06-03.
2026-06-30 19:27:59 +01:00

71 lines
2.4 KiB
Python

"""Stdout logging — works correctly under Docker's PYTHONUNBUFFERED=1.
Two logger families share the root handler:
* `samsung_appliance` (and its children) for module-level lines —
DTLS warnings, generic startup chatter, MQTT plumbing.
* `<class>.<serial>` for per-appliance bridge lines — e.g.
`dryer.<serial>`. Each PushBridge gets its own such logger
via bridge_logger() once the seed reveals the appliance's serial.
Both trees propagate to the root logger, which is the one with the
StreamHandler, so the same format applies everywhere.
WARNING lines render yellow, ERROR red, when colour is enabled. Set
`NO_COLOR=1` in the environment to fall back to plain text (e.g. when
writing logs to a file)."""
import logging
import os
import sys
_LEVEL_COLOURS = {
logging.WARNING: '\033[33m', # yellow
logging.ERROR: '\033[31m', # red
logging.CRITICAL: '\033[1;31m', # bold red
}
_RESET = '\033[0m'
def _colour_enabled() -> bool:
return 'NO_COLOR' not in os.environ
class _LevelColourFormatter(logging.Formatter):
"""Wraps the rendered line in an ANSI colour for WARNING+ levels.
INFO/DEBUG pass through unchanged so the bulk of the log stays
readable and a yellow line draws the eye."""
def __init__(self, fmt: str, datefmt: str, use_colour: bool):
super().__init__(fmt=fmt, datefmt=datefmt)
self.use_colour = use_colour
def format(self, record: logging.LogRecord) -> str:
line = super().format(record)
if not self.use_colour:
return line
colour = _LEVEL_COLOURS.get(record.levelno)
if colour is None:
return line
return f"{colour}{line}{_RESET}"
_handler = logging.StreamHandler(sys.stdout)
_handler.setFormatter(_LevelColourFormatter(
fmt='%(asctime)s %(levelname)-5s %(name)-26s %(message)s',
datefmt='%H:%M:%S',
use_colour=_colour_enabled(),
))
logging.basicConfig(level=logging.INFO, handlers=[_handler], force=True)
logger = logging.getLogger("samsung_appliance")
def bridge_logger(klass: str, serial: str | None = None) -> logging.Logger:
"""Return a top-level logger tagged with the appliance class and,
once known, the serial. Pre-seed callers pass serial=None and get
e.g. `dryer`; post-seed callers pass the serial and get e.g.
`dryer.<serial>`."""
name = f"{klass}.{serial}" if serial else klass
return logging.getLogger(name)