Merge branch 'main' into claude/device-support-issue-80-cycle-labels

This commit is contained in:
Marc Billow authored and GitHub committed 2026-07-26 21:51:23 -05:00
commit 0b6eda0cdc
32 files changed
+1918 -30

No files matched your search

@@ -87,6 +87,26 @@ _CONSUMER_PREFIX_TO_KEY: dict[str, str] = {
}
def _consumer_model_key(description: str) -> Optional[str]:
"""Registry key from the consumer-model token in `description`, or None.
Usually that token is the last '_'-delimited segment before any
'/board-info' suffix (e.g. '..._WW90DG6U25LEU4' -> 'WW90DG6U25LEU4').
But issue #79's dryer pairs two model numbers in one description --
'..._DVE50A8800_8600/DC92-...' -- so the true consumer token
('DVE50A8800') sits one segment *before* the actual last segment
('8600', a bare second model number with no recognizable prefix). Scan
segments from the end and take the first one that resolves, rather
than assuming the last segment is always it.
"""
segments = (description or '').split('/', 1)[0].split('_')
for segment in reversed(segments):
key = _CONSUMER_PREFIX_TO_KEY.get(segment[:2].upper())
if key is not None:
return key
return None
def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegistry]:
"""Fallback device-type detection for hardware that never reports
oneUiVersion (confirmed for washers -- their /otninformation/vs/0 has
@@ -100,8 +120,7 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
DeviceRegistry if the consumer-model code or modelNum resolves to a
known type, None otherwise.
"""
token = (description or '').split('/', 1)[0].rsplit('_', 1)[-1]
key = _CONSUMER_PREFIX_TO_KEY.get(token[:2].upper())
key = _consumer_model_key(description)
if key is None and '_REF_' in (model_num or ''):
key = 'refrigerator'
# Room air conditioners (e.g. ARTIK051_PRAC_20K) report no oneUiVersion and
@@ -170,4 +189,18 @@ def for_device_by_resources(resources: dict[str, dict]) -> Optional[DeviceRegist
and '/hood/lamp/vs/0' in resources
):
return _REGISTRY_BY_KEY['range_hood']
# Oven/range-combo boards that report no /information/vs/0 at all
# (issue #74's NE63B8411SS -- the resource is simply absent from the
# dump, not just empty) can't be matched via for_device_by_model's
# modelNum tokens either. 'Bake' is oven/range cook-mode vocabulary that
# no other family's /mode/vs/0 uses (confirmed against the microwave,
# cooktop, and every laundry fixture), so its presence alongside the
# oven cavity resource is a safe signature. Distinguish range (has a
# cooktop half) from a plain wall oven by which cooktop-status resource,
# if any, is also present.
supported_modes = mode.get('x.com.samsung.da.supportedModes') or ()
if '/oven/vs/0' in resources and 'Bake' in supported_modes:
if '/cooktopmonitoring/vs/0' in resources or '/cooktop/status/vs/0' in resources:
return _REGISTRY_BY_KEY['range']
return _REGISTRY_BY_KEY['oven']
return None
@@ -25,6 +25,9 @@ REGISTRY = DeviceRegistry(
airconditioner.DISPLAY_LIGHT,
airconditioner.MUTE_ONCE,
airconditioner.CURRENT_LIMIT,
airconditioner.CURRENT_TEMPERATURE,
airconditioner.CURRENT_TEMPERATURE_VS,
airconditioner.HUMIDITY,
*airconditioner.COVERAGE,
]),
)
@@ -25,5 +25,6 @@ REGISTRY = DeviceRegistry(
range_caps.COOKTOP_STATUS,
range_caps.COOKTOP_SPEC,
range_caps.COOKTOP_SAFETY,
range_caps.COOKTOP_MONITORING,
]),
)
@@ -33,7 +33,7 @@ REGISTRY = DeviceRegistry(
]),
pattern_capabilities=[
fridge.TEMP_CURRENT_GENERIC,
fridge.TEMP_SETPOINT_GENERIC,
fridge.TEMP_SETPOINT,
fridge.ICEMAKER_GENERIC,
fridge.DOOR_GENERIC,
],
@@ -16,6 +16,7 @@ by_type registry.
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, ClimateDesc, SensorDesc, SwitchDesc
from .common import normalize_temp_unit
# ---------------------------------------------------------------------------
# Canonical AC resource hrefs. The climate entity (climate.py) binds the
@@ -50,6 +51,25 @@ def _num(v):
return None
def _temps_vs_item(rep):
"""First item of the vendor `/temperatures/vs/0` items[] array -- the
Tizen Lite board's only current-temperature source (see climate.py's
identical helper; duplicated rather than imported to avoid a
capabilities<->platform import cycle)."""
items = rep.get('x.com.samsung.da.items')
if isinstance(items, (list, tuple)) and items and isinstance(items[0], dict):
return items[0]
return {}
def _temps_vs_current(rep):
return _num(_temps_vs_item(rep).get('x.com.samsung.da.current'))
def _temps_vs_unit(rep):
return normalize_temp_unit(_temps_vs_item(rep).get('x.com.samsung.da.unit'), '°C')
def _filter_usage_percent(rep):
"""Filter usage as a percentage of rated capacity. The device reports
`filterUsage` as a raw count in `filterCapacityUnit` (Hours here, e.g.
@@ -199,6 +219,48 @@ CURRENT_LIMIT = Capability(
),
)
# The climate entity already surfaces current_temperature as a card
# attribute, but that's not enough for history graphs/automations/
# statistics -- issue #75 asked for a standalone sensor. Same OCF-standard-
# with-vendor-fallback shape as common.py's POWER_GENERIC/POWER_VS_FALLBACK
# pair: both share key='current_temperature_c' so only one ever binds
# (match_fn gates the vendor one off when the OCF resource is present).
CURRENT_TEMPERATURE = Capability(
href=HREF_TEMP_CURRENT,
poll_tier='warm',
entities=(
SensorDesc(key='current_temperature_c', field='temperature',
device_class='temperature', state_class='measurement',
unit_fn=lambda rep: normalize_temp_unit(rep.get('units'), '°C')),
),
)
CURRENT_TEMPERATURE_VS = Capability(
href=HREF_TEMPS_VS,
poll_tier='warm',
match_fn=lambda rep, resources: HREF_TEMP_CURRENT not in resources,
entities=(
SensorDesc(key='current_temperature_c', rep_fn=_temps_vs_current,
device_class='temperature', state_class='measurement',
unit_fn=_temps_vs_unit),
),
)
# Only the vendor resource's `fivepercentHumidity` (current reading, rounded
# to the nearest 5%) has live data on the issue #75 dump -- its `humidity`
# field, and the OCF-standard /humidity/0 resource entirely, both read a
# stuck "0" there and stay ignored per the 'don't guess' rule (see
# _AC_IGNORED below).
HUMIDITY = Capability(
href='/humidity/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='humidity', field='x.com.samsung.da.fivepercentHumidity',
device_class='humidity', state_class='measurement', unit='%',
value_fn=_num),
),
)
# ---------------------------------------------------------------------------
# AC-scoped coverage: the CLIMATE_CONSUMED_HREFS above (read by the climate
# entity) plus vendor duplicates / all-zero-ambiguous / plumbing resources.
@@ -221,8 +283,10 @@ _AC_IGNORED = [
# All-zero and ambiguously encoded on this model (2-value arrays); the
# 'don't guess' rule -- leave unmodeled rather than invent entities.
'/sensors/vs/0',
# Stuck at "0" on every dump seen -- HUMIDITY above reads the vendor
# resource's usable fivepercentHumidity field instead; this OCF-standard
# one has no corresponding live value confirmed yet.
'/humidity/0',
'/humidity/vs/0',
# Presence-personalization plumbing (empty item list here).
'/personality/presence/vs/0',
# --- TP1X/TP2X-class housekeeping / opaque blobs. These carry no
@@ -251,8 +315,11 @@ _AC_IGNORED = [
]
# Built as bare no-entity caps; folded into the AC registry (not global).
# HREF_TEMP_CURRENT and HREF_TEMPS_VS are excluded here -- CURRENT_TEMPERATURE
# / CURRENT_TEMPERATURE_VS above already cover those two with real entities.
COVERAGE = [
Capability(href=h, poll_tier='warm') for h in CLIMATE_CONSUMED_HREFS
if h not in (HREF_TEMP_CURRENT, HREF_TEMPS_VS)
] + [
Capability(href=h) for h in _AC_IGNORED
]
@@ -59,9 +59,21 @@ def _ml_to_l(v):
def _active_alarm_codes(items):
"""Join active alarm codes; skip retained rows Samsung leaves as Deleted.
Laundry boards keep a Deleted ErrorCode row in /alarms/vs/0 after the
condition clears (see WD7000B diagnostics). Surface only live alarms so
HA doesn't stick on a stale ErrorCode. Range-hood has its own stricter
helper that also drops ErrorCode_OFF.
"""
if not items or not isinstance(items, list):
return 'none'
codes = [i.get('x.com.samsung.da.code') for i in items if i.get('x.com.samsung.da.code')]
codes = [
i.get('x.com.samsung.da.code')
for i in items
if i.get('x.com.samsung.da.code')
and str(i.get('x.com.samsung.da.state', '')).lower() != 'deleted'
]
return ', '.join(codes) if codes else 'none'
@@ -92,6 +104,52 @@ def merge_options_field(cached, new_tokens):
return merged
# /wm/setinfo/vs/0 -- laundry-family firmware capability flags. Present on
# washers, dryers, and dishwashers; absent on fridge/oven/AC. Static for the
# life of a given board, so reading them from the /device/0 seed (no dedicated
# poll_tier) is enough.
_SETINFO_HREF = '/wm/setinfo/vs/0'
_POWER_ON_OFF_FIELD = 'x.com.samsung.da.isModelSettingPowerOnOff'
_WITHOUT_SC_FIELD = 'x.com.samsung.da.isModelSettingWithoutSC'
def model_allows_power_on_off(resources: dict) -> bool:
"""True unless firmware explicitly declares remote power on/off unsupported.
`/wm/setinfo/vs/0`.`isModelSettingPowerOnOff` is `"false"` on many laundry
boards (washers/dryers): `/power/0` and `/power/vs/0` still report state,
but CoAP writes are ignored. Absent setinfo (non-laundry families) keeps
the writable switch -- current behavior.
"""
setinfo = resources.get(_SETINFO_HREF)
if setinfo is None:
return True
flag = setinfo.get(_POWER_ON_OFF_FIELD)
if flag is None:
return True
return str(flag).lower() != 'false'
def model_setting_without_sc(resources: dict) -> bool:
"""True when firmware declares settings writable without Smart Control.
`/wm/setinfo/vs/0`.`isModelSettingWithoutSC` is `"true"` on washers/dryers
that accept temperature/spin/cycle-option writes while remote control is
off. Cycle start/pause/stop still need Smart Control on those boards --
the flag name is settings-specific, not a blanket remote-control bypass.
"""
setinfo = resources.get(_SETINFO_HREF) or {}
return str(setinfo.get(_WITHOUT_SC_FIELD, '')).lower() == 'true'
def _power_switch_exists(rep, resources):
return model_allows_power_on_off(resources)
def _power_sensor_exists(rep, resources):
return not model_allows_power_on_off(resources)
def sensor_item_value(items, sensor_type, index=0):
"""Pull one reading out of a `/sensors/vs/0`-style items[] list -- each
item is `{type, value: [...]}`; `index` picks which slot of a possibly
@@ -128,10 +186,17 @@ def sensor_item_value(items, sensor_type, index=0):
POWER_GENERIC = Capability(
href='/power/0',
entities=(
# Writable when firmware allows remote power; otherwise a read-only
# binary_sensor with the same key keeps HA state without a dead switch.
SwitchDesc(key='power_switch', field='value',
value_fn=lambda v: bool(v),
exists_fn=_power_switch_exists,
write_fn=lambda p, rep, href=None: (
['power', '0'], {'value': p == 'On'})),
BinarySensorDesc(key='power_switch', field='value',
device_class='power',
value_fn=lambda v: bool(v),
exists_fn=_power_sensor_exists),
),
)
@@ -141,9 +206,14 @@ POWER_VS_FALLBACK = Capability(
entities=(
SwitchDesc(key='power_switch', field='x.com.samsung.da.power',
value_fn=lambda v: v == 'On',
exists_fn=_power_switch_exists,
write_fn=lambda p, rep, href=None: (
['power', 'vs', '0'],
{'x.com.samsung.da.power': 'On' if p == 'On' else 'Off'})),
BinarySensorDesc(key='power_switch', field='x.com.samsung.da.power',
device_class='power',
value_fn=lambda v: v == 'On',
exists_fn=_power_sensor_exists),
),
)
@@ -192,6 +262,20 @@ def remote_control_enabled(resources: dict) -> bool:
return True
def remote_control_required_for_write(resources: dict, bound_href: str) -> bool:
"""Whether a write to bound_href should be gated on Smart Control.
When isModelSettingWithoutSC is true, laundry firmware accepts settings
writes (wash temp, spin, course options, buzzer, ...) with remote
control off, but cycle start/pause/stop on /operational/state still
need Smart Control. Absent that flag, keep the historical blanket gate.
"""
if not model_setting_without_sc(resources):
return True
href = bound_href or ''
return href.startswith('/operational/state')
REMOTE_CONTROL_GENERIC = Capability(
href='/remotectrl/0',
poll_tier='warm',
@@ -62,7 +62,38 @@ TEMP_CURRENT_GENERIC = Capability(
),
)
TEMP_SETPOINT_GENERIC = Capability(
def _temp_setpoint_write(p, rep, href=None, resources=None):
"""Write temperature — prefer vendor /temperatures/vs/0 when available,
fall back to direct OCF /temperature/desired/ write otherwise.
Samsung fridges expose both OCF-standard /temperature/desired/* and vendor
/temperatures/vs/0. On some models only the vendor path commits the change;
on others both work. Using the vendor path when present is always correct.
Item IDs follow the Samsung convention: "0" = Freezer, "1" = Fridge/Cooler.
"""
if not href:
return None
if resources and '/temperatures/vs/0' in resources:
if '/cooler/' in href:
item_id = '1'
elif '/freezer/' in href:
item_id = '0'
else:
return None
return (
['temperatures', 'vs', '0'],
{'x.com.samsung.da.items': [
{'x.com.samsung.da.id': item_id,
'x.com.samsung.da.desired': str(int(round(float(p))))}
]}
)
return (
[s for s in href.strip('/').split('/') if s],
{'temperature': int(round(float(p)))}
)
TEMP_SETPOINT = Capability(
href=None,
href_prefix='/temperature/desired/',
strip_prefix_in_key=True,
@@ -73,10 +104,7 @@ TEMP_SETPOINT_GENERIC = Capability(
use_instance_name=True, device_class='temperature', unit_fn=_temp_unit,
native_min=-20.0, native_max=50.0,
range_field='range', entity_category='config',
write_fn=lambda p, rep, href=None: (
[s for s in href.strip('/').split('/') if s],
{'temperature': int(round(float(p)))}
) if href else None),
write_fn=_temp_setpoint_write),
),
)
@@ -133,3 +133,22 @@ COOKTOP_SAFETY = Capability(
value_fn=lambda v: (v or {}).get('state') == 'on'),
),
)
# Some range boards (issue #74's NE63B8411SS) report no /cooktop/status/vs/0
# burner array at all -- their local API only exposes this coarse
# monitoring resource for the cooktop half, with no per-burner detail.
# Meaning of `cooktopMonitoring` (a bare "0" on the only dump seen) and
# `warmingCenterState`'s full value set aren't confirmed, so both are
# exposed as plain sensors rather than guessed at as a switch/select --
# `supportedHoodLampStateList` has no corresponding live-state field on
# this resource, so nothing to bind it to yet.
COOKTOP_MONITORING = Capability(
href='/cooktopmonitoring/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='cooktop_running_state', field='x.com.samsung.da.cooktopRunningState',
icon='mdi:pot-steam-outline'),
SensorDesc(key='warming_center_state', field='x.com.samsung.da.warmingCenterState',
icon='mdi:heat-wave', entity_category='diagnostic'),
),
)