Merge branch 'main' into claude/device-support-issue-80-cycle-labels
This commit is contained in:
32 files changed
+1918
-30
No files matched your search
@@ -87,6 +87,26 @@ _CONSUMER_PREFIX_TO_KEY: dict[str, str] = {
|
||||
}
|
||||
|
||||
|
||||
def _consumer_model_key(description: str) -> Optional[str]:
|
||||
"""Registry key from the consumer-model token in `description`, or None.
|
||||
|
||||
Usually that token is the last '_'-delimited segment before any
|
||||
'/board-info' suffix (e.g. '..._WW90DG6U25LEU4' -> 'WW90DG6U25LEU4').
|
||||
But issue #79's dryer pairs two model numbers in one description --
|
||||
'..._DVE50A8800_8600/DC92-...' -- so the true consumer token
|
||||
('DVE50A8800') sits one segment *before* the actual last segment
|
||||
('8600', a bare second model number with no recognizable prefix). Scan
|
||||
segments from the end and take the first one that resolves, rather
|
||||
than assuming the last segment is always it.
|
||||
"""
|
||||
segments = (description or '').split('/', 1)[0].split('_')
|
||||
for segment in reversed(segments):
|
||||
key = _CONSUMER_PREFIX_TO_KEY.get(segment[:2].upper())
|
||||
if key is not None:
|
||||
return key
|
||||
return None
|
||||
|
||||
|
||||
def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegistry]:
|
||||
"""Fallback device-type detection for hardware that never reports
|
||||
oneUiVersion (confirmed for washers -- their /otninformation/vs/0 has
|
||||
@@ -100,8 +120,7 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
DeviceRegistry if the consumer-model code or modelNum resolves to a
|
||||
known type, None otherwise.
|
||||
"""
|
||||
token = (description or '').split('/', 1)[0].rsplit('_', 1)[-1]
|
||||
key = _CONSUMER_PREFIX_TO_KEY.get(token[:2].upper())
|
||||
key = _consumer_model_key(description)
|
||||
if key is None and '_REF_' in (model_num or ''):
|
||||
key = 'refrigerator'
|
||||
# Room air conditioners (e.g. ARTIK051_PRAC_20K) report no oneUiVersion and
|
||||
@@ -170,4 +189,18 @@ def for_device_by_resources(resources: dict[str, dict]) -> Optional[DeviceRegist
|
||||
and '/hood/lamp/vs/0' in resources
|
||||
):
|
||||
return _REGISTRY_BY_KEY['range_hood']
|
||||
# Oven/range-combo boards that report no /information/vs/0 at all
|
||||
# (issue #74's NE63B8411SS -- the resource is simply absent from the
|
||||
# dump, not just empty) can't be matched via for_device_by_model's
|
||||
# modelNum tokens either. 'Bake' is oven/range cook-mode vocabulary that
|
||||
# no other family's /mode/vs/0 uses (confirmed against the microwave,
|
||||
# cooktop, and every laundry fixture), so its presence alongside the
|
||||
# oven cavity resource is a safe signature. Distinguish range (has a
|
||||
# cooktop half) from a plain wall oven by which cooktop-status resource,
|
||||
# if any, is also present.
|
||||
supported_modes = mode.get('x.com.samsung.da.supportedModes') or ()
|
||||
if '/oven/vs/0' in resources and 'Bake' in supported_modes:
|
||||
if '/cooktopmonitoring/vs/0' in resources or '/cooktop/status/vs/0' in resources:
|
||||
return _REGISTRY_BY_KEY['range']
|
||||
return _REGISTRY_BY_KEY['oven']
|
||||
return None
|
||||
@@ -25,6 +25,9 @@ REGISTRY = DeviceRegistry(
|
||||
airconditioner.DISPLAY_LIGHT,
|
||||
airconditioner.MUTE_ONCE,
|
||||
airconditioner.CURRENT_LIMIT,
|
||||
airconditioner.CURRENT_TEMPERATURE,
|
||||
airconditioner.CURRENT_TEMPERATURE_VS,
|
||||
airconditioner.HUMIDITY,
|
||||
*airconditioner.COVERAGE,
|
||||
]),
|
||||
)
|
||||
@@ -25,5 +25,6 @@ REGISTRY = DeviceRegistry(
|
||||
range_caps.COOKTOP_STATUS,
|
||||
range_caps.COOKTOP_SPEC,
|
||||
range_caps.COOKTOP_SAFETY,
|
||||
range_caps.COOKTOP_MONITORING,
|
||||
]),
|
||||
)
|
||||
@@ -33,7 +33,7 @@ REGISTRY = DeviceRegistry(
|
||||
]),
|
||||
pattern_capabilities=[
|
||||
fridge.TEMP_CURRENT_GENERIC,
|
||||
fridge.TEMP_SETPOINT_GENERIC,
|
||||
fridge.TEMP_SETPOINT,
|
||||
fridge.ICEMAKER_GENERIC,
|
||||
fridge.DOOR_GENERIC,
|
||||
],
|
||||
|
||||
@@ -16,6 +16,7 @@ by_type registry.
|
||||
"""
|
||||
from ..capability import Capability
|
||||
from ..entities import BinarySensorDesc, ClimateDesc, SensorDesc, SwitchDesc
|
||||
from .common import normalize_temp_unit
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Canonical AC resource hrefs. The climate entity (climate.py) binds the
|
||||
@@ -50,6 +51,25 @@ def _num(v):
|
||||
return None
|
||||
|
||||
|
||||
def _temps_vs_item(rep):
|
||||
"""First item of the vendor `/temperatures/vs/0` items[] array -- the
|
||||
Tizen Lite board's only current-temperature source (see climate.py's
|
||||
identical helper; duplicated rather than imported to avoid a
|
||||
capabilities<->platform import cycle)."""
|
||||
items = rep.get('x.com.samsung.da.items')
|
||||
if isinstance(items, (list, tuple)) and items and isinstance(items[0], dict):
|
||||
return items[0]
|
||||
return {}
|
||||
|
||||
|
||||
def _temps_vs_current(rep):
|
||||
return _num(_temps_vs_item(rep).get('x.com.samsung.da.current'))
|
||||
|
||||
|
||||
def _temps_vs_unit(rep):
|
||||
return normalize_temp_unit(_temps_vs_item(rep).get('x.com.samsung.da.unit'), '°C')
|
||||
|
||||
|
||||
def _filter_usage_percent(rep):
|
||||
"""Filter usage as a percentage of rated capacity. The device reports
|
||||
`filterUsage` as a raw count in `filterCapacityUnit` (Hours here, e.g.
|
||||
@@ -199,6 +219,48 @@ CURRENT_LIMIT = Capability(
|
||||
),
|
||||
)
|
||||
|
||||
# The climate entity already surfaces current_temperature as a card
|
||||
# attribute, but that's not enough for history graphs/automations/
|
||||
# statistics -- issue #75 asked for a standalone sensor. Same OCF-standard-
|
||||
# with-vendor-fallback shape as common.py's POWER_GENERIC/POWER_VS_FALLBACK
|
||||
# pair: both share key='current_temperature_c' so only one ever binds
|
||||
# (match_fn gates the vendor one off when the OCF resource is present).
|
||||
CURRENT_TEMPERATURE = Capability(
|
||||
href=HREF_TEMP_CURRENT,
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SensorDesc(key='current_temperature_c', field='temperature',
|
||||
device_class='temperature', state_class='measurement',
|
||||
unit_fn=lambda rep: normalize_temp_unit(rep.get('units'), '°C')),
|
||||
),
|
||||
)
|
||||
|
||||
CURRENT_TEMPERATURE_VS = Capability(
|
||||
href=HREF_TEMPS_VS,
|
||||
poll_tier='warm',
|
||||
match_fn=lambda rep, resources: HREF_TEMP_CURRENT not in resources,
|
||||
entities=(
|
||||
SensorDesc(key='current_temperature_c', rep_fn=_temps_vs_current,
|
||||
device_class='temperature', state_class='measurement',
|
||||
unit_fn=_temps_vs_unit),
|
||||
),
|
||||
)
|
||||
|
||||
# Only the vendor resource's `fivepercentHumidity` (current reading, rounded
|
||||
# to the nearest 5%) has live data on the issue #75 dump -- its `humidity`
|
||||
# field, and the OCF-standard /humidity/0 resource entirely, both read a
|
||||
# stuck "0" there and stay ignored per the 'don't guess' rule (see
|
||||
# _AC_IGNORED below).
|
||||
HUMIDITY = Capability(
|
||||
href='/humidity/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SensorDesc(key='humidity', field='x.com.samsung.da.fivepercentHumidity',
|
||||
device_class='humidity', state_class='measurement', unit='%',
|
||||
value_fn=_num),
|
||||
),
|
||||
)
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# AC-scoped coverage: the CLIMATE_CONSUMED_HREFS above (read by the climate
|
||||
# entity) plus vendor duplicates / all-zero-ambiguous / plumbing resources.
|
||||
@@ -221,8 +283,10 @@ _AC_IGNORED = [
|
||||
# All-zero and ambiguously encoded on this model (2-value arrays); the
|
||||
# 'don't guess' rule -- leave unmodeled rather than invent entities.
|
||||
'/sensors/vs/0',
|
||||
# Stuck at "0" on every dump seen -- HUMIDITY above reads the vendor
|
||||
# resource's usable fivepercentHumidity field instead; this OCF-standard
|
||||
# one has no corresponding live value confirmed yet.
|
||||
'/humidity/0',
|
||||
'/humidity/vs/0',
|
||||
# Presence-personalization plumbing (empty item list here).
|
||||
'/personality/presence/vs/0',
|
||||
# --- TP1X/TP2X-class housekeeping / opaque blobs. These carry no
|
||||
@@ -251,8 +315,11 @@ _AC_IGNORED = [
|
||||
]
|
||||
|
||||
# Built as bare no-entity caps; folded into the AC registry (not global).
|
||||
# HREF_TEMP_CURRENT and HREF_TEMPS_VS are excluded here -- CURRENT_TEMPERATURE
|
||||
# / CURRENT_TEMPERATURE_VS above already cover those two with real entities.
|
||||
COVERAGE = [
|
||||
Capability(href=h, poll_tier='warm') for h in CLIMATE_CONSUMED_HREFS
|
||||
if h not in (HREF_TEMP_CURRENT, HREF_TEMPS_VS)
|
||||
] + [
|
||||
Capability(href=h) for h in _AC_IGNORED
|
||||
]
|
||||
@@ -59,9 +59,21 @@ def _ml_to_l(v):
|
||||
|
||||
|
||||
def _active_alarm_codes(items):
|
||||
"""Join active alarm codes; skip retained rows Samsung leaves as Deleted.
|
||||
|
||||
Laundry boards keep a Deleted ErrorCode row in /alarms/vs/0 after the
|
||||
condition clears (see WD7000B diagnostics). Surface only live alarms so
|
||||
HA doesn't stick on a stale ErrorCode. Range-hood has its own stricter
|
||||
helper that also drops ErrorCode_OFF.
|
||||
"""
|
||||
if not items or not isinstance(items, list):
|
||||
return 'none'
|
||||
codes = [i.get('x.com.samsung.da.code') for i in items if i.get('x.com.samsung.da.code')]
|
||||
codes = [
|
||||
i.get('x.com.samsung.da.code')
|
||||
for i in items
|
||||
if i.get('x.com.samsung.da.code')
|
||||
and str(i.get('x.com.samsung.da.state', '')).lower() != 'deleted'
|
||||
]
|
||||
return ', '.join(codes) if codes else 'none'
|
||||
|
||||
|
||||
@@ -92,6 +104,52 @@ def merge_options_field(cached, new_tokens):
|
||||
return merged
|
||||
|
||||
|
||||
# /wm/setinfo/vs/0 -- laundry-family firmware capability flags. Present on
|
||||
# washers, dryers, and dishwashers; absent on fridge/oven/AC. Static for the
|
||||
# life of a given board, so reading them from the /device/0 seed (no dedicated
|
||||
# poll_tier) is enough.
|
||||
_SETINFO_HREF = '/wm/setinfo/vs/0'
|
||||
_POWER_ON_OFF_FIELD = 'x.com.samsung.da.isModelSettingPowerOnOff'
|
||||
_WITHOUT_SC_FIELD = 'x.com.samsung.da.isModelSettingWithoutSC'
|
||||
|
||||
|
||||
def model_allows_power_on_off(resources: dict) -> bool:
|
||||
"""True unless firmware explicitly declares remote power on/off unsupported.
|
||||
|
||||
`/wm/setinfo/vs/0`.`isModelSettingPowerOnOff` is `"false"` on many laundry
|
||||
boards (washers/dryers): `/power/0` and `/power/vs/0` still report state,
|
||||
but CoAP writes are ignored. Absent setinfo (non-laundry families) keeps
|
||||
the writable switch -- current behavior.
|
||||
"""
|
||||
setinfo = resources.get(_SETINFO_HREF)
|
||||
if setinfo is None:
|
||||
return True
|
||||
flag = setinfo.get(_POWER_ON_OFF_FIELD)
|
||||
if flag is None:
|
||||
return True
|
||||
return str(flag).lower() != 'false'
|
||||
|
||||
|
||||
def model_setting_without_sc(resources: dict) -> bool:
|
||||
"""True when firmware declares settings writable without Smart Control.
|
||||
|
||||
`/wm/setinfo/vs/0`.`isModelSettingWithoutSC` is `"true"` on washers/dryers
|
||||
that accept temperature/spin/cycle-option writes while remote control is
|
||||
off. Cycle start/pause/stop still need Smart Control on those boards --
|
||||
the flag name is settings-specific, not a blanket remote-control bypass.
|
||||
"""
|
||||
setinfo = resources.get(_SETINFO_HREF) or {}
|
||||
return str(setinfo.get(_WITHOUT_SC_FIELD, '')).lower() == 'true'
|
||||
|
||||
|
||||
def _power_switch_exists(rep, resources):
|
||||
return model_allows_power_on_off(resources)
|
||||
|
||||
|
||||
def _power_sensor_exists(rep, resources):
|
||||
return not model_allows_power_on_off(resources)
|
||||
|
||||
|
||||
def sensor_item_value(items, sensor_type, index=0):
|
||||
"""Pull one reading out of a `/sensors/vs/0`-style items[] list -- each
|
||||
item is `{type, value: [...]}`; `index` picks which slot of a possibly
|
||||
@@ -128,10 +186,17 @@ def sensor_item_value(items, sensor_type, index=0):
|
||||
POWER_GENERIC = Capability(
|
||||
href='/power/0',
|
||||
entities=(
|
||||
# Writable when firmware allows remote power; otherwise a read-only
|
||||
# binary_sensor with the same key keeps HA state without a dead switch.
|
||||
SwitchDesc(key='power_switch', field='value',
|
||||
value_fn=lambda v: bool(v),
|
||||
exists_fn=_power_switch_exists,
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['power', '0'], {'value': p == 'On'})),
|
||||
BinarySensorDesc(key='power_switch', field='value',
|
||||
device_class='power',
|
||||
value_fn=lambda v: bool(v),
|
||||
exists_fn=_power_sensor_exists),
|
||||
),
|
||||
)
|
||||
|
||||
@@ -141,9 +206,14 @@ POWER_VS_FALLBACK = Capability(
|
||||
entities=(
|
||||
SwitchDesc(key='power_switch', field='x.com.samsung.da.power',
|
||||
value_fn=lambda v: v == 'On',
|
||||
exists_fn=_power_switch_exists,
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['power', 'vs', '0'],
|
||||
{'x.com.samsung.da.power': 'On' if p == 'On' else 'Off'})),
|
||||
BinarySensorDesc(key='power_switch', field='x.com.samsung.da.power',
|
||||
device_class='power',
|
||||
value_fn=lambda v: v == 'On',
|
||||
exists_fn=_power_sensor_exists),
|
||||
),
|
||||
)
|
||||
|
||||
@@ -192,6 +262,20 @@ def remote_control_enabled(resources: dict) -> bool:
|
||||
return True
|
||||
|
||||
|
||||
def remote_control_required_for_write(resources: dict, bound_href: str) -> bool:
|
||||
"""Whether a write to bound_href should be gated on Smart Control.
|
||||
|
||||
When isModelSettingWithoutSC is true, laundry firmware accepts settings
|
||||
writes (wash temp, spin, course options, buzzer, ...) with remote
|
||||
control off, but cycle start/pause/stop on /operational/state still
|
||||
need Smart Control. Absent that flag, keep the historical blanket gate.
|
||||
"""
|
||||
if not model_setting_without_sc(resources):
|
||||
return True
|
||||
href = bound_href or ''
|
||||
return href.startswith('/operational/state')
|
||||
|
||||
|
||||
REMOTE_CONTROL_GENERIC = Capability(
|
||||
href='/remotectrl/0',
|
||||
poll_tier='warm',
|
||||
|
||||
@@ -62,7 +62,38 @@ TEMP_CURRENT_GENERIC = Capability(
|
||||
),
|
||||
)
|
||||
|
||||
TEMP_SETPOINT_GENERIC = Capability(
|
||||
def _temp_setpoint_write(p, rep, href=None, resources=None):
|
||||
"""Write temperature — prefer vendor /temperatures/vs/0 when available,
|
||||
fall back to direct OCF /temperature/desired/ write otherwise.
|
||||
|
||||
Samsung fridges expose both OCF-standard /temperature/desired/* and vendor
|
||||
/temperatures/vs/0. On some models only the vendor path commits the change;
|
||||
on others both work. Using the vendor path when present is always correct.
|
||||
Item IDs follow the Samsung convention: "0" = Freezer, "1" = Fridge/Cooler.
|
||||
"""
|
||||
if not href:
|
||||
return None
|
||||
if resources and '/temperatures/vs/0' in resources:
|
||||
if '/cooler/' in href:
|
||||
item_id = '1'
|
||||
elif '/freezer/' in href:
|
||||
item_id = '0'
|
||||
else:
|
||||
return None
|
||||
return (
|
||||
['temperatures', 'vs', '0'],
|
||||
{'x.com.samsung.da.items': [
|
||||
{'x.com.samsung.da.id': item_id,
|
||||
'x.com.samsung.da.desired': str(int(round(float(p))))}
|
||||
]}
|
||||
)
|
||||
return (
|
||||
[s for s in href.strip('/').split('/') if s],
|
||||
{'temperature': int(round(float(p)))}
|
||||
)
|
||||
|
||||
|
||||
TEMP_SETPOINT = Capability(
|
||||
href=None,
|
||||
href_prefix='/temperature/desired/',
|
||||
strip_prefix_in_key=True,
|
||||
@@ -73,10 +104,7 @@ TEMP_SETPOINT_GENERIC = Capability(
|
||||
use_instance_name=True, device_class='temperature', unit_fn=_temp_unit,
|
||||
native_min=-20.0, native_max=50.0,
|
||||
range_field='range', entity_category='config',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
[s for s in href.strip('/').split('/') if s],
|
||||
{'temperature': int(round(float(p)))}
|
||||
) if href else None),
|
||||
write_fn=_temp_setpoint_write),
|
||||
),
|
||||
)
|
||||
|
||||
|
||||
@@ -133,3 +133,22 @@ COOKTOP_SAFETY = Capability(
|
||||
value_fn=lambda v: (v or {}).get('state') == 'on'),
|
||||
),
|
||||
)
|
||||
|
||||
# Some range boards (issue #74's NE63B8411SS) report no /cooktop/status/vs/0
|
||||
# burner array at all -- their local API only exposes this coarse
|
||||
# monitoring resource for the cooktop half, with no per-burner detail.
|
||||
# Meaning of `cooktopMonitoring` (a bare "0" on the only dump seen) and
|
||||
# `warmingCenterState`'s full value set aren't confirmed, so both are
|
||||
# exposed as plain sensors rather than guessed at as a switch/select --
|
||||
# `supportedHoodLampStateList` has no corresponding live-state field on
|
||||
# this resource, so nothing to bind it to yet.
|
||||
COOKTOP_MONITORING = Capability(
|
||||
href='/cooktopmonitoring/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SensorDesc(key='cooktop_running_state', field='x.com.samsung.da.cooktopRunningState',
|
||||
icon='mdi:pot-steam-outline'),
|
||||
SensorDesc(key='warming_center_state', field='x.com.samsung.da.warmingCenterState',
|
||||
icon='mdi:heat-wave', entity_category='diagnostic'),
|
||||
),
|
||||
)
|
||||
Reference in new issue
Block a user