Merge pull request #390 from JayChickenK/air-purifier-co2
air_purifier: expose CO2 when the device lists it
This commit is contained in:
9 files changed
+155
-40
No files matched your search
@@ -7,8 +7,9 @@ only); this registry deliberately doesn't include common.POWER.
|
||||
air_purifier.AIR_QUALITY and range_hood.AIR_QUALITY already read via
|
||||
common.sensor_item_value -- reused here rather than re-decoded, including
|
||||
the same dust/fine_dust/super_fine_dust/odor/clean_level keys so this
|
||||
device shares those capabilities' catalog entries. This board additionally
|
||||
reports a CO2 reading the other two families don't.
|
||||
device shares those capabilities' catalog entries. This board reports a
|
||||
CO2 reading; air_purifier.AIR_QUALITY now models the same type when a
|
||||
purifier lists it (issue #387).
|
||||
|
||||
A second `value` list element on the particulate-matter types (Dust's
|
||||
`['31', '2']`) is the device's own graded air-quality level for that
|
||||
|
||||
@@ -34,7 +34,13 @@ from ..entities import (
|
||||
SwitchDesc,
|
||||
TimeDesc,
|
||||
)
|
||||
from .common import epoch_to_utc, filter_usage_percent, int_or_none, sensor_item_value
|
||||
from .common import (
|
||||
epoch_to_utc,
|
||||
filter_usage_percent,
|
||||
has_sensor_type,
|
||||
int_or_none,
|
||||
sensor_item_value,
|
||||
)
|
||||
from .laundry import bool_option_exists, bool_option_value, option_value, option_write
|
||||
|
||||
# Newer TP1X_DA-AC-AIR-class boards (issue #130) report fan modes directly
|
||||
@@ -106,17 +112,35 @@ _AIR_QUALITY_SENSORS = (
|
||||
AIR_QUALITY = Capability(
|
||||
href="/sensors/vs/0",
|
||||
poll_tier="warm",
|
||||
entities=tuple(
|
||||
entities=(
|
||||
*(
|
||||
SensorDesc(
|
||||
key=key,
|
||||
field="x.com.samsung.da.items",
|
||||
icon=icon,
|
||||
state_class=state_class,
|
||||
device_class=device_class,
|
||||
unit=unit,
|
||||
value_fn=lambda items, t=sensor_type: sensor_item_value(items, t),
|
||||
)
|
||||
for key, icon, sensor_type, state_class, device_class, unit in _AIR_QUALITY_SENSORS
|
||||
),
|
||||
# CO2 (issue #387) -- same field/shape air_monitor.SENSORS already
|
||||
# models with device_class='carbon_dioxide'/unit='ppm'. Gated on the
|
||||
# type being listed so boards that don't report it (every current
|
||||
# fixture) don't grow an empty entity. Disabled by default for the
|
||||
# same reason as airconditioner.AIR_QUALITY (issue #166).
|
||||
SensorDesc(
|
||||
key=key,
|
||||
key="co2",
|
||||
field="x.com.samsung.da.items",
|
||||
icon=icon,
|
||||
state_class=state_class,
|
||||
device_class=device_class,
|
||||
unit=unit,
|
||||
value_fn=lambda items, t=sensor_type: sensor_item_value(items, t),
|
||||
)
|
||||
for key, icon, sensor_type, state_class, device_class, unit in _AIR_QUALITY_SENSORS
|
||||
icon="mdi:molecule-co2",
|
||||
device_class="carbon_dioxide",
|
||||
state_class="measurement",
|
||||
unit="ppm",
|
||||
exists_fn=has_sensor_type("CO2"),
|
||||
enabled_default=False,
|
||||
value_fn=lambda items: sensor_item_value(items, "CO2"),
|
||||
),
|
||||
),
|
||||
)
|
||||
|
||||
|
||||
@@ -23,7 +23,7 @@ from ..entities import (
|
||||
SwitchDesc,
|
||||
)
|
||||
from . import common
|
||||
from .common import filter_usage_hours, filter_usage_percent, normalize_temp_unit
|
||||
from .common import filter_usage_hours, filter_usage_percent, has_sensor_type, normalize_temp_unit
|
||||
from .laundry import option_write
|
||||
|
||||
|
||||
@@ -119,26 +119,6 @@ def _sensor_item_value(items, type_):
|
||||
return None
|
||||
|
||||
|
||||
def _has_sensor_type(type_):
|
||||
"""True when /sensors/vs/0's items[] lists an item of this type.
|
||||
|
||||
This only proves the type is *listed*, not that the reading is real:
|
||||
issue #166 (ARTIK051_PRAC_20K) lists all five types with permanent-zero
|
||||
values on units the reporter confirmed don't have the hardware. So
|
||||
entities gated on this stay disabled by default (see AIR_QUALITY) rather
|
||||
than existence-gated further, to avoid silently dropping real readings
|
||||
on hardware not yet seen.
|
||||
"""
|
||||
|
||||
def fn(rep, resources):
|
||||
return any(
|
||||
isinstance(i, dict) and i.get("x.com.samsung.da.type") == type_
|
||||
for i in (rep.get("x.com.samsung.da.items") or [])
|
||||
)
|
||||
|
||||
return fn
|
||||
|
||||
|
||||
# Canonical AC resource hrefs. climate.py binds HREF_MODE and reads the
|
||||
# CLIMATE_CONSUMED_HREFS siblings off the coordinator snapshot; declared once
|
||||
# here so climate.py and the coverage list below can't drift out of sync.
|
||||
@@ -1570,7 +1550,7 @@ WINDSLEEP = Capability(
|
||||
# /sensors/vs/0 items[] carry live air-quality readings. CleanLevel is
|
||||
# corroborated as numeric by a top-level x.com.samsung.da.cleanLevel scalar,
|
||||
# so it's a measurement; the others stay string diagnostics (see
|
||||
# _sensor_item_value). All disabled by default: _has_sensor_type only proves
|
||||
# _sensor_item_value). All disabled by default: has_sensor_type only proves
|
||||
# the item type is listed, not that the sensor is real (see its docstring).
|
||||
AIR_QUALITY = Capability(
|
||||
href="/sensors/vs/0",
|
||||
@@ -1582,7 +1562,7 @@ AIR_QUALITY = Capability(
|
||||
icon="mdi:broom",
|
||||
entity_category="diagnostic",
|
||||
state_class="measurement",
|
||||
exists_fn=_has_sensor_type("CleanLevel"),
|
||||
exists_fn=has_sensor_type("CleanLevel"),
|
||||
enabled_default=False,
|
||||
value_fn=lambda items: _int(_sensor_item_value(items, "CleanLevel")),
|
||||
),
|
||||
@@ -1592,7 +1572,7 @@ AIR_QUALITY = Capability(
|
||||
field="x.com.samsung.da.items",
|
||||
icon=icon,
|
||||
entity_category="diagnostic",
|
||||
exists_fn=_has_sensor_type(type_),
|
||||
exists_fn=has_sensor_type(type_),
|
||||
enabled_default=False,
|
||||
value_fn=lambda items, t=type_: _sensor_item_value(items, t),
|
||||
)
|
||||
@@ -1618,7 +1598,7 @@ AIR_QUALITY = Capability(
|
||||
device_class="carbon_dioxide",
|
||||
state_class="measurement",
|
||||
unit="ppm",
|
||||
exists_fn=_has_sensor_type("CO2"),
|
||||
exists_fn=has_sensor_type("CO2"),
|
||||
enabled_default=False,
|
||||
value_fn=lambda items: _int(_sensor_item_value(items, "CO2")),
|
||||
),
|
||||
|
||||
@@ -299,6 +299,30 @@ def sensor_item_value(items, sensor_type, index=0):
|
||||
return None
|
||||
|
||||
|
||||
def has_sensor_type(type_):
|
||||
"""True when /sensors/vs/0's items[] lists an item of this type.
|
||||
|
||||
This only proves the type is *listed*, not that the reading is real:
|
||||
issue #166 (ARTIK051_PRAC_20K) lists all five types with permanent-zero
|
||||
values on units the reporter confirmed don't have the hardware. So
|
||||
entities gated on this stay disabled by default rather than
|
||||
existence-gated further, to avoid silently dropping real readings on
|
||||
hardware not yet seen.
|
||||
|
||||
is_stub_rep(rep) keeps the stub carve-out (see entity._is_included /
|
||||
ENERGY_METER, issue #127): an explicit exists_fn otherwise bypasses it
|
||||
and would drop the entity when /device/0 returns a not-yet-fetched stub.
|
||||
"""
|
||||
|
||||
def fn(rep, resources):
|
||||
return is_stub_rep(rep) or any(
|
||||
isinstance(i, dict) and i.get("x.com.samsung.da.type") == type_
|
||||
for i in (rep.get("x.com.samsung.da.items") or [])
|
||||
)
|
||||
|
||||
return fn
|
||||
|
||||
|
||||
# OCF-native / vendor '-vs' fallback pairs for power, kids-lock, remote
|
||||
# control: each exists as both a standard OCF resource (/power/0,
|
||||
# oic.r.switch.binary, plain boolean 'value') and a Samsung vendor
|
||||
|
||||
Reference in new issue
Block a user