Fix PM unit codepoint and document the /sensors/vs/0 grade column
Review follow-up to PR #365, which landed the washer 0A/B0 labels and the air-purifier PM device classes. The three particulate units were spelled with U+00B5 MICRO SIGN. Home Assistant's DEVICE_CLASS_UNITS holds only the U+03BC GREEK SMALL LETTER MU spelling, so every purifier logged a per-entity "not a valid unit for the device class" warning asking the user to file a bug against us. The two characters render identically, and the PR's own test hardcoded the wrong one, so the test agreed with the bug. That test now takes the expected unit from HA's own constant, and a new registry-wide guard (test_sensor_device_class_units.py, mirroring the SwitchDesc guard from issue #349) checks every SensorDesc unit against HA -- these were the only three invalid pairs among 29. Getting this in before release matters more than usual: the recorder writes unit_of_measurement into long-term statistics, so correcting it afterwards would raise a "units changed" repair for anyone who had run the released version. Also settles what the second element of a dust reading's value[] is, which was the open question behind issue #325's request for another dump. It is the device's own graded air-quality level: it appears only on the fields carrying a magnitude (Dust/FineDust/SuperFineDust/CO2) and not on Odor/CleanLevel, which are grades already; it reads 0-2 against index 0's 0-31; and CleanLevel equals the highest per-field grade on 9 of the 11 fixtures reporting the resource. It stays unbound -- ARTIK051_TVTL grades good air as 0 while every other family uses 1, so a shared descriptor would need a per-family offset -- but it is what confirms the PM mapping without relying on field names: 18 grades one step above the floor as SuperFineDust yet sits at the floor as Dust, on two families that both floor at 1, so the firmware itself treats the three fields as different scales ordered coarse-to-fine. Each field's floor boundary also brackets the Korean CAI band for its tier (PM10 at 30/31, PM2.5 at 15/16). Pinned against the shipped fixtures in test_air_quality_grade_column.py. air_monitor keeps its untyped sensors, but the docstring now gives the real reason: the evidence carries over, and what is deliberately deferred is the statistics migration for entities shipped unitless since issue #210. Smaller fixes: en.json's "Mixed load" -> "Mixed Load" to match the catalog's title casing and issue #363's own wording; de/ko gave B0 the same string as the existing "34" Mixed, so a machine exposing both showed two identical options; washer.py's shared-label list still said "'24' Towels", which went stale when issue #343 found 24/33 transposed; and 0A/B0 now have a locale-wide translation guard like every other confirmed code batch.
This commit is contained in:
1 parent
627b761462
commit
21af5708cb
12 files changed
+360
-37
No files matched your search
@@ -10,17 +10,23 @@ the same dust/fine_dust/super_fine_dust/odor/clean_level keys so this
|
||||
device shares those capabilities' catalog entries. This board additionally
|
||||
reports a CO2 reading the other two families don't.
|
||||
|
||||
A second `value` list element on the particulate-matter types (e.g. Dust's
|
||||
`['31', '2']`) reads like a coarse quality-grade code, but nothing on this
|
||||
board confirms what its scale means -- left unbound rather than guessed;
|
||||
index 0 is the only slot any family has ever read.
|
||||
A second `value` list element on the particulate-matter types (Dust's
|
||||
`['31', '2']`) is the device's own graded air-quality level for that
|
||||
reading -- see common.sensor_item_value. Still unbound here: the grade's
|
||||
floor differs by board family, and CleanLevel already carries the
|
||||
aggregate. This board's own readings are load-bearing evidence for the
|
||||
PM mapping, though: 23 grading one step above the floor as FineDust is
|
||||
what rules out a PM10-width band for that field.
|
||||
|
||||
Dust/FineDust/SuperFineDust stay without an HA `device_class`/`unit` on
|
||||
this board. The three-tier mapping (Dust=PM10, FineDust=PM2.5,
|
||||
SuperFineDust=PM1, µg/m³) is confirmed for the air-purifier family
|
||||
(issue #325) but this standalone monitor has no same-moment app
|
||||
correlation of its own, so it keeps the untyped measurement sensors
|
||||
rather than inheriting that label.
|
||||
Dust/FineDust/SuperFineDust nevertheless stay without an HA
|
||||
`device_class`/`unit` here, which is now a migration call rather than an
|
||||
evidence gap. The mapping confirmed for the purifier family (issue #325,
|
||||
Dust=PM10 / FineDust=PM2.5 / SuperFineDust=PM1 in μg/m³) rests on
|
||||
device-side grading that this board shares, so it would carry over. But
|
||||
these five sensors have recorded unitless long-term statistics since
|
||||
issue #210, and stamping a unit onto an existing statistic is what raises
|
||||
Home Assistant's "units changed" repair -- a deliberate follow-up, not
|
||||
something to fold into the purifier's first typed release.
|
||||
"""
|
||||
|
||||
from datetime import time as dt_time
|
||||
@@ -35,8 +41,9 @@ from .common import int_or_none, sensor_item_value
|
||||
# graded indices on that family, while this board has stamped all five as
|
||||
# `measurement` since it was added (issue #210). Consuming state_class would
|
||||
# silently drop long-term statistics for two sensors on shipped devices, and
|
||||
# the pm10/pm25/pm1 labels are confirmed only for the purifier family
|
||||
# (issue #325). The shared rows supply only the key/icon/type here.
|
||||
# the pm10/pm25/pm1 labels are held back pending the statistics migration
|
||||
# the module docstring describes. The shared rows supply only the
|
||||
# key/icon/type here.
|
||||
SENSORS = Capability(
|
||||
href="/sensors/vs/0",
|
||||
poll_tier="warm",
|
||||
|
||||
@@ -67,14 +67,38 @@ def _has_top_level_modes(rep, resources):
|
||||
# indices instead, where the mean of a grade isn't obviously meaningful; left
|
||||
# without a state_class rather than guessing.
|
||||
#
|
||||
# device_class/unit confirmed on a live ARTIK051_TVTL against the SmartThings
|
||||
# app at the same moment (issue #325): Dust=PM10, FineDust=PM2.5,
|
||||
# SuperFineDust=PM1, all µg/m³. Dust matched PM10 exactly; the other two
|
||||
# were 1 µg/m³ off the app, same order.
|
||||
# device_class/unit: Dust=PM10, FineDust=PM2.5, SuperFineDust=PM1, all
|
||||
# μg/m³ (issue #325). Three independent lines, none of them naming order --
|
||||
# which is what the earlier "plausible but unconfirmed" note rejected:
|
||||
#
|
||||
# 1. The device grades its own readings. Each dust item's value[] is
|
||||
# [concentration, grade] (see common.sensor_item_value); the grade band
|
||||
# is not shared across the three fields -- a reading of 18 grades one
|
||||
# step *above* the floor as SuperFineDust (air_monitor fixture) but *at*
|
||||
# the floor as Dust (range_hood fixture), both 1-based families. So the
|
||||
# firmware itself treats them as three different scales ordered
|
||||
# coarse-to-fine, rather than one repeated measurement.
|
||||
# 2. Where each field's floor/second-band boundary falls brackets the
|
||||
# Korean CAI bands: Dust good at 18, graded up at 31 (CAI PM10 breaks
|
||||
# at 30/31); FineDust good at 14, graded up at 23 (CAI PM2.5 breaks at
|
||||
# 15/16); SuperFineDust good at 9, graded up at 18 (PM2.5-style, which
|
||||
# is what a PM1 reading gets -- there is no standard PM1 index).
|
||||
# 3. A live ARTIK051_TVTL read against the SmartThings app at the same
|
||||
# moment: Dust matched the app's PM10 exactly, the other two were 1
|
||||
# μg/m³ off in the same order, and the app shows exactly these three
|
||||
# tiers, so there is no fourth candidate to assign.
|
||||
#
|
||||
# Dust >= FineDust >= SuperFineDust holds on all 11 fixtures that report
|
||||
# this resource, which is the cumulative-mass ordering PM10 >= PM2.5 >= PM1
|
||||
# requires by definition. The unit literal must stay HA's own spelling of
|
||||
# μg/m³ (U+03BC GREEK SMALL LETTER MU, not U+00B5 MICRO SIGN) -- they render
|
||||
# alike but only U+03BC is in DEVICE_CLASS_UNITS, and the mismatch is a
|
||||
# runtime warning per entity, not a test failure. Pinned by
|
||||
# tests/test_sensor_device_class_units.py.
|
||||
_AIR_QUALITY_SENSORS = (
|
||||
("dust", "mdi:blur", "Dust", "measurement", "pm10", "µg/m³"),
|
||||
("fine_dust", "mdi:blur", "FineDust", "measurement", "pm25", "µg/m³"),
|
||||
("super_fine_dust", "mdi:blur", "SuperFineDust", "measurement", "pm1", "µg/m³"),
|
||||
("dust", "mdi:blur", "Dust", "measurement", "pm10", "μg/m³"),
|
||||
("fine_dust", "mdi:blur", "FineDust", "measurement", "pm25", "μg/m³"),
|
||||
("super_fine_dust", "mdi:blur", "SuperFineDust", "measurement", "pm1", "μg/m³"),
|
||||
("odor", "mdi:scent", "Odor", None, None, None),
|
||||
("clean_level", "mdi:air-filter", "CleanLevel", None, None, None),
|
||||
)
|
||||
|
||||
@@ -101,8 +101,15 @@ def _threshold_write(payload, rep, href=None):
|
||||
def _sensor_item_value(items, type_):
|
||||
"""First value of the /sensors/vs/0 item with the given
|
||||
x.com.samsung.da.type. Dust/FineDust/SuperFineDust report a 2-element
|
||||
array; only v[0] is used, since the second element's meaning is
|
||||
unconfirmed. No device_class is set: the resource exposes no unit."""
|
||||
array; only v[0] is used. v[1] is the device's own graded air-quality
|
||||
level for that reading, left unbound because its floor differs by
|
||||
family -- see common.sensor_item_value for the full note.
|
||||
|
||||
No device_class here: unlike air_purifier (issue #325), no AC family
|
||||
has had its dust readings correlated against the app, and every AC
|
||||
fixture reports permanent zeros or ties, so this file's own dumps
|
||||
supply no grade-band evidence either. Returns a string rather than an
|
||||
int, which these diagnostic entities have always done."""
|
||||
for it in items or []:
|
||||
if isinstance(it, dict) and it.get("x.com.samsung.da.type") == type_:
|
||||
v = it.get("x.com.samsung.da.value")
|
||||
|
||||
@@ -254,7 +254,29 @@ def sensor_item_value(items, sensor_type, index=0):
|
||||
item is `{type, value: [...]}`; `index` picks which slot to read
|
||||
(index 0 is the raw measurement on every family seen so far). Shared
|
||||
by range_hood.AIR_QUALITY, air_purifier.AIR_QUALITY, and
|
||||
air_monitor.SENSORS, which all read the same resource shape."""
|
||||
air_monitor.SENSORS, which all read the same resource shape.
|
||||
|
||||
value[] is 2-element on the fields that carry a magnitude
|
||||
(Dust/FineDust/SuperFineDust/CO2) and 1-element on Odor/CleanLevel.
|
||||
That asymmetry is what index 1 means: it is the device's own graded
|
||||
air-quality level for that reading -- the same kind of value Odor and
|
||||
CleanLevel already *are*, which is why those two have no second slot.
|
||||
It reads 0-2 against index 0's observed 0-31, tracks index 0 within a
|
||||
device, and CleanLevel equals the highest per-field grade on 9 of the
|
||||
11 fixtures reporting this resource (the range hood and one RAC report
|
||||
a higher CleanLevel than any dust grade, so they fold in something
|
||||
else).
|
||||
|
||||
Index 1 is deliberately left unbound rather than exposed as an entity:
|
||||
its floor is not portable. ARTIK051_TVTL grades good air as 0, while
|
||||
AVT-WW-TP1 / A-VTWW-TP2 / TP1X / ASM-KR-TP1 / AHD-WW-TP1 all grade it
|
||||
as 1, so a shared descriptor would need a per-family offset to mean
|
||||
anything, and CleanLevel already carries the aggregate. The grade is
|
||||
still load-bearing as *evidence*: it is what confirms the three dust
|
||||
fields are three different scales rather than one repeated reading --
|
||||
see air_purifier._AIR_QUALITY_SENSORS and
|
||||
tests/test_air_quality_grade_column.py.
|
||||
"""
|
||||
for item in items or ():
|
||||
if not isinstance(item, dict):
|
||||
continue
|
||||
|
||||
@@ -40,10 +40,11 @@ from .laundry import (
|
||||
# implying anything about a plain washer's '1F'); 3 more (Eco Cold, Towels,
|
||||
# Self Clean+) verified directly on a WF50A8600AV/US by reading back the raw
|
||||
# code after selecting each cycle on the appliance (issue #80). 2 more
|
||||
# ('0A' Towels, 'B0' Mixed load) reported for a WW90DG5G34ABLE on the same
|
||||
# Table_02 family (issue #363). Two code pairs ('21'/'65' Colors,
|
||||
# '27'/'5E' Rinse+Spin, and '24'/'54' Towels) legitimately share a label
|
||||
# across different course tables -- not typos.
|
||||
# ('0A' Towels, 'B0' Mixed Load) reported for a WW90DG5G34ABLE on the same
|
||||
# Table_02 family (issue #363). Several codes legitimately share a label
|
||||
# across different course tables -- '21'/'65' Colors, '27'/'5E'/'78'
|
||||
# Rinse+Spin, '0A'/'33'/'54'/'70' Towels -- not typos. (This list said
|
||||
# "'24' Towels" until issue #343 found 24/33 transposed; 24 is Bedding.)
|
||||
#
|
||||
# No static fallback list is kept here: other models have different actual
|
||||
# course sets, so hardcoding one device's list would show/hide the wrong
|
||||
|
||||
@@ -657,7 +657,7 @@
|
||||
"8f": "Kaltwäsche Intensiv",
|
||||
"96": "Weniger Mikrofasern",
|
||||
"a0": "Schnelle Wäsche 15'",
|
||||
"b0": "Mischwäsche",
|
||||
"b0": "Gemischte Beladung",
|
||||
"17": "Heruntergeladen",
|
||||
"69": "KI-Wäsche",
|
||||
"6a": "Wolle",
|
||||
|
||||
@@ -714,7 +714,7 @@
|
||||
"8f": "Intense Cold",
|
||||
"96": "Less Microfiber",
|
||||
"a0": "15' Quick Wash",
|
||||
"b0": "Mixed load"
|
||||
"b0": "Mixed Load"
|
||||
}
|
||||
},
|
||||
"washer_dry_level": {
|
||||
|
||||
@@ -695,7 +695,7 @@
|
||||
"8f": "강력 냉수 세탁",
|
||||
"96": "미세플라스틱저감",
|
||||
"a0": "15분 쾌속세탁",
|
||||
"b0": "혼합",
|
||||
"b0": "혼합 세탁",
|
||||
"69": "AI 맞춤세탁",
|
||||
"6a": "울",
|
||||
"6b": "데님",
|
||||
|
||||
Reference in new issue