Fix PM unit codepoint and document the /sensors/vs/0 grade column
Review follow-up to PR #365, which landed the washer 0A/B0 labels and the air-purifier PM device classes. The three particulate units were spelled with U+00B5 MICRO SIGN. Home Assistant's DEVICE_CLASS_UNITS holds only the U+03BC GREEK SMALL LETTER MU spelling, so every purifier logged a per-entity "not a valid unit for the device class" warning asking the user to file a bug against us. The two characters render identically, and the PR's own test hardcoded the wrong one, so the test agreed with the bug. That test now takes the expected unit from HA's own constant, and a new registry-wide guard (test_sensor_device_class_units.py, mirroring the SwitchDesc guard from issue #349) checks every SensorDesc unit against HA -- these were the only three invalid pairs among 29. Getting this in before release matters more than usual: the recorder writes unit_of_measurement into long-term statistics, so correcting it afterwards would raise a "units changed" repair for anyone who had run the released version. Also settles what the second element of a dust reading's value[] is, which was the open question behind issue #325's request for another dump. It is the device's own graded air-quality level: it appears only on the fields carrying a magnitude (Dust/FineDust/SuperFineDust/CO2) and not on Odor/CleanLevel, which are grades already; it reads 0-2 against index 0's 0-31; and CleanLevel equals the highest per-field grade on 9 of the 11 fixtures reporting the resource. It stays unbound -- ARTIK051_TVTL grades good air as 0 while every other family uses 1, so a shared descriptor would need a per-family offset -- but it is what confirms the PM mapping without relying on field names: 18 grades one step above the floor as SuperFineDust yet sits at the floor as Dust, on two families that both floor at 1, so the firmware itself treats the three fields as different scales ordered coarse-to-fine. Each field's floor boundary also brackets the Korean CAI band for its tier (PM10 at 30/31, PM2.5 at 15/16). Pinned against the shipped fixtures in test_air_quality_grade_column.py. air_monitor keeps its untyped sensors, but the docstring now gives the real reason: the evidence carries over, and what is deliberately deferred is the statistics migration for entities shipped unitless since issue #210. Smaller fixes: en.json's "Mixed load" -> "Mixed Load" to match the catalog's title casing and issue #363's own wording; de/ko gave B0 the same string as the existing "34" Mixed, so a machine exposing both showed two identical options; washer.py's shared-label list still said "'24' Towels", which went stale when issue #343 found 24/33 transposed; and 0A/B0 now have a locale-wide translation guard like every other confirmed code batch.
This commit is contained in:
1 parent
627b761462
commit
21af5708cb
12 files changed
+360
-37
No files matched your search
@@ -31,12 +31,20 @@ def test_graded_sensors_are_left_without_a_state_class():
|
||||
|
||||
|
||||
def test_particulate_sensors_declare_pm_device_class_and_unit():
|
||||
"""Live same-moment SmartThings correlation on ARTIK051_TVTL (issue #325)
|
||||
maps Dust/FineDust/SuperFineDust to PM10/PM2.5/PM1 in µg/m³."""
|
||||
"""Dust/FineDust/SuperFineDust map to PM10/PM2.5/PM1 (issue #325) -- see
|
||||
air_purifier._AIR_QUALITY_SENSORS for the three lines of evidence and
|
||||
tests/test_air_quality_grade_column.py for the device-side ones.
|
||||
|
||||
The expected unit comes from HA's own constant rather than a literal:
|
||||
typing it out is how PR #365 landed U+00B5 MICRO SIGN where HA uses
|
||||
U+03BC, which renders identically and would make this test agree with
|
||||
the bug."""
|
||||
from homeassistant.const import CONCENTRATION_MICROGRAMS_PER_CUBIC_METER as UG_M3
|
||||
|
||||
expected = {
|
||||
"dust": ("pm10", "µg/m³"),
|
||||
"fine_dust": ("pm25", "µg/m³"),
|
||||
"super_fine_dust": ("pm1", "µg/m³"),
|
||||
"dust": ("pm10", UG_M3),
|
||||
"fine_dust": ("pm25", UG_M3),
|
||||
"super_fine_dust": ("pm1", UG_M3),
|
||||
}
|
||||
for key, (device_class, unit) in expected.items():
|
||||
desc = _desc(key)
|
||||
@@ -48,13 +56,17 @@ def test_particulate_sensors_declare_pm_device_class_and_unit():
|
||||
assert desc.unit is None, key
|
||||
|
||||
|
||||
def test_state_class_comes_from_the_shared_tuples_fourth_column():
|
||||
"""The rows carry their own state_class rather than a parallel lookup, so
|
||||
a new sensor can't be added here without deciding the question."""
|
||||
def test_metadata_comes_from_the_shared_tuples_own_columns():
|
||||
"""The rows carry their own state_class/device_class/unit rather than a
|
||||
parallel lookup, so a new sensor can't be added here without deciding
|
||||
each question. Unit validity against HA is a separate guard --
|
||||
tests/test_sensor_device_class_units.py."""
|
||||
for row in air_purifier._AIR_QUALITY_SENSORS:
|
||||
assert len(row) == 6, row
|
||||
assert row[3] in ("measurement", None), row
|
||||
assert row[4] in ("pm10", "pm25", "pm1", None), row
|
||||
# A device_class without a unit would leave HA inferring one.
|
||||
assert (row[4] is None) == (row[5] is None), row
|
||||
|
||||
|
||||
def test_air_monitor_keeps_stamping_every_shared_sensor():
|
||||
|
||||
Reference in new issue
Block a user