Merge pull request #267 from kkqq9320/fix/air-quality-state-class

fix(air_purifier): record long-term statistics for the particulate sensors
This commit is contained in:
Marc Billow authored and GitHub committed 2026-08-05 19:55:56 -04:00
commit 26e4c9c167
3 files changed
+109 -7

No files matched your search

@@ -31,6 +31,12 @@ from ..entities import BinarySensorDesc, SensorDesc, SwitchDesc, TimeDesc
from .air_purifier import _AIR_QUALITY_SENSORS
from .common import int_or_none, sensor_item_value
# _AIR_QUALITY_SENSORS' fourth column (state_class) is deliberately discarded
# here: air_purifier leaves Odor/CleanLevel unstamped because they read as
# graded indices on that family, while this board has stamped all five as
# `measurement` since it was added (issue #210). Consuming the column would
# silently drop long-term statistics for two sensors on shipped devices, so
# the shared rows supply only the key/icon/type here.
SENSORS = Capability(
href="/sensors/vs/0",
poll_tier="warm",
@@ -43,7 +49,7 @@ SENSORS = Capability(
state_class="measurement",
value_fn=lambda items, t=sensor_type: sensor_item_value(items, t),
)
for key, icon, sensor_type in _AIR_QUALITY_SENSORS
for key, icon, sensor_type, _ in _AIR_QUALITY_SENSORS
),
SensorDesc(
key="co2",
@@ -51,12 +51,31 @@ def _has_top_level_modes(rep, resources):
return isinstance(rep.get("x.com.samsung.da.supportedModes"), (list, tuple))
# The fourth column is state_class, which is what makes Home Assistant keep
# long-term statistics for a sensor -- without one, a reading is only in the
# short-term recorder history and disappears with the next purge (10 days by
# default), so it can't back a long-range air-quality graph. The values are
# already numeric (sensor_item_value returns int), so nothing else was in the
# way; three sensors in this same module (filter_progress, fan_speed_level,
# hepa_filter_usage) already declare one.
#
# Only the three particulate readings get it. They fall monotonically with
# particle size on three independent board families -- 11/9/5 on ARTIK051_TVTL
# (issue #56), 10/9/6 on AVT-WW-TP1 (issue #190), 18/14/9 on the range hood --
# which is concentration behaviour, and an average over time is meaningful for
# it. Odor and CleanLevel read 0-2 on every fixture and look like graded
# indices instead, where the mean of a grade isn't obviously meaningful; left
# without a state_class rather than guessing.
#
# Deliberately no device_class/unit here: pm1/pm25/pm10 would assert the
# reading is a µg/m³ concentration, and the dumps never say so. That's a
# separate call from making the series recordable at all.
_AIR_QUALITY_SENSORS = (
("dust", "mdi:blur", "Dust"),
("fine_dust", "mdi:blur", "FineDust"),
("super_fine_dust", "mdi:blur", "SuperFineDust"),
("odor", "mdi:scent", "Odor"),
("clean_level", "mdi:air-filter", "CleanLevel"),
("dust", "mdi:blur", "Dust", "measurement"),
("fine_dust", "mdi:blur", "FineDust", "measurement"),
("super_fine_dust", "mdi:blur", "SuperFineDust", "measurement"),
("odor", "mdi:scent", "Odor", None),
("clean_level", "mdi:air-filter", "CleanLevel", None),
)
AIR_QUALITY = Capability(
@@ -67,9 +86,10 @@ AIR_QUALITY = Capability(
key=key,
field="x.com.samsung.da.items",
icon=icon,
state_class=state_class,
value_fn=lambda items, t=sensor_type: sensor_item_value(items, t),
)
for key, icon, sensor_type in _AIR_QUALITY_SENSORS
for key, icon, sensor_type, state_class in _AIR_QUALITY_SENSORS
),
)