feat(registry): cover absence-power-saving and motion-detect-wind on AC (#173)
Lennox-branded heat pump on the Samsung RAC board family (modelNum TP1X_LNX-AC-RAC-01001_0000) already routes correctly via the existing '-RAC-' token, but its dump has two resources no prior AC fixture carried: /mds/absencepowersaving/vs/0 and /option/motiondetectwind/stateful/vs/0. Bind both as read-only sensors, matching the CURRENT_LIMIT/ANOMALY_LOAD precedent -- nothing in the dump confirms write safety on live HVAC hardware.
This commit is contained in:
8 files changed
+820
No files matched your search
@@ -27,6 +27,8 @@ REGISTRY = DeviceRegistry(
|
||||
airconditioner.MUTE_ONCE,
|
||||
airconditioner.CURRENT_LIMIT,
|
||||
airconditioner.ANOMALY_LOAD,
|
||||
airconditioner.ABSENCE_POWER_SAVING,
|
||||
airconditioner.MOTION_DETECT_WIND,
|
||||
airconditioner.CURRENT_TEMPERATURE,
|
||||
airconditioner.CURRENT_TEMPERATURE_VS,
|
||||
airconditioner.HUMIDITY,
|
||||
|
||||
@@ -677,6 +677,52 @@ ANOMALY_LOAD = Capability(
|
||||
),
|
||||
)
|
||||
|
||||
# Absence-detection power-saving (issue #173, TP1X_LNX-AC-RAC-01001 --
|
||||
# Lennox-branded heat pump on the RAC board family): `status` toggles the
|
||||
# feature, `switchPowerSaveMode` picks the save intensity out of its own
|
||||
# supportedSwitchPowerSaveMode list. A third field, `motionState`, also
|
||||
# carries a supportedMotionState list but its role (a live sensor readout vs.
|
||||
# a sensitivity setting) isn't distinguishable from the dump, so it's left
|
||||
# unmodeled. Same 'don't guess' read-only treatment as CURRENT_LIMIT/
|
||||
# ANOMALY_LOAD above -- nothing here confirms write safety on live HVAC
|
||||
# hardware.
|
||||
ABSENCE_POWER_SAVING = Capability(
|
||||
href='/mds/absencepowersaving/vs/0',
|
||||
poll_tier='cold',
|
||||
entities=(
|
||||
BinarySensorDesc(key='absence_power_saving_active', field='status',
|
||||
icon='mdi:human-greeting-proximity',
|
||||
entity_category='diagnostic',
|
||||
value_fn=lambda v: v == 'On'),
|
||||
SensorDesc(key='absence_power_saving_mode', field='switchPowerSaveMode',
|
||||
device_class='enum',
|
||||
options=('eco', 'normal', 'comfort'),
|
||||
translation_key='absence_power_saving_mode',
|
||||
icon='mdi:leaf', entity_category='diagnostic',
|
||||
value_fn=lambda v: v.lower() if isinstance(v, str) else v),
|
||||
),
|
||||
)
|
||||
|
||||
# Avoid-direct-wind-on-motion, a sibling AI feature to ABSENCE_POWER_SAVING
|
||||
# above on the same dump: `status` toggles it, `modes` picks Direct/Indirect
|
||||
# airflow out of `supportedModes`. Same read-only treatment.
|
||||
MOTION_DETECT_WIND = Capability(
|
||||
href='/option/motiondetectwind/stateful/vs/0',
|
||||
poll_tier='cold',
|
||||
entities=(
|
||||
BinarySensorDesc(key='motion_detect_wind_active', field='status',
|
||||
icon='mdi:motion-sensor',
|
||||
entity_category='diagnostic',
|
||||
value_fn=lambda v: v == 'On'),
|
||||
SensorDesc(key='motion_detect_wind_mode', field='modes',
|
||||
device_class='enum',
|
||||
options=('direct', 'indirect'),
|
||||
translation_key='motion_detect_wind_mode',
|
||||
icon='mdi:weather-windy', entity_category='diagnostic',
|
||||
value_fn=lambda v: v.lower() if isinstance(v, str) else v),
|
||||
),
|
||||
)
|
||||
|
||||
# The climate entity already surfaces current_temperature as a card
|
||||
# attribute, but that's not enough for history graphs/automations/
|
||||
# statistics -- issue #75 asked for a standalone sensor. Same OCF-standard-
|
||||
|
||||
Reference in new issue