feat(registry): cover absence-power-saving and motion-detect-wind on AC (#173)
Lennox-branded heat pump on the Samsung RAC board family (modelNum TP1X_LNX-AC-RAC-01001_0000) already routes correctly via the existing '-RAC-' token, but its dump has two resources no prior AC fixture carried: /mds/absencepowersaving/vs/0 and /option/motiondetectwind/stateful/vs/0. Bind both as read-only sensors, matching the CURRENT_LIMIT/ANOMALY_LOAD precedent -- nothing in the dump confirms write safety on live HVAC hardware.
This commit is contained in:
8 files changed
+820
No files matched your search
@@ -0,0 +1,24 @@
|
||||
{
|
||||
"state_keys": [
|
||||
"absence_power_saving_active",
|
||||
"absence_power_saving_mode",
|
||||
"air_filter_status",
|
||||
"air_filter_usage",
|
||||
"air_filter_usage_hours",
|
||||
"alarm_code",
|
||||
"auto_clean",
|
||||
"beep",
|
||||
"climate",
|
||||
"current_temperature_c",
|
||||
"display_light",
|
||||
"energy_kwh",
|
||||
"energy_saved_kwh",
|
||||
"firmware_update",
|
||||
"humidity",
|
||||
"motion_detect_wind_active",
|
||||
"motion_detect_wind_mode",
|
||||
"mute_once",
|
||||
"power_watts",
|
||||
"tropical_night_mode"
|
||||
]
|
||||
}
|
||||
Reference in new issue