Fix airflow fan power-href preference and unique_id collision risk

Opus review of the previous commit caught two real bugs. The airflow fan's
power writes preferred /power/vs/0, copied from the TP1X fan class -- but
that order is only harmless there because TP1X never reports /power/0 at
all. This family's dumps carry both hrefs, and the power_switch entity is
unconditionally bound to /power/0 when present, so the fan was writing to
a different resource than power_switch reads/writes, leaving the two
entities disagreeing until the next poll. Flipped to prefer /power/0,
matching the range hood's fan and common.POWER_GENERIC.

Also renamed the new FanDesc's key from 'fan' to 'airflow_fan': BoundEntity
unique_ids are derived from key alone, not href, so it collided with
air_purifier.FAN's own 'fan' key on the (currently unobserved, but
unenforced) possibility of a board reporting both.

Added a platform-level test file covering the power-href preference and
percentage<->speed-code mapping, mirroring test_range_hood_fan.py's harness.
This commit is contained in:
Marc Billow committed 2026-07-27 21:48:23 +00:00
1 parent d4583b3240
commit 2be742489b
6 files changed
+148 -24

No files matched your search

@@ -136,16 +136,6 @@ DEVICE_ACTIVE = Capability(
),
)
# Confirmed via issue #56's second, properly-spaced round of diagnostics
# (two independent units, 60-90s apart per setting): /airflow/0's `speed` is
# a clean, monotonic 0-4 code across Auto/Sleep/Low/Medium/High, so it now
# backs a real ordered-speed fan (fan.py's LocalThingsAirflowFan, same
# SET_SPEED shape as the range hood's) instead of a read-only sensor --
# no named-preset table needed, since HA's percentage steps map onto the
# raw 0-4 code directly, the same way the range hood's numeric levels do.
# `direction` stays a plain diagnostic: every dump seen (both rounds, both
# units) reads 'Off' for it regardless of fan setting, so there's nothing
# confirmed to control there yet.
def _airflow_fan_write(payload, rep, href=None):
kind, value, *args = payload
if kind == 'power':
@@ -159,11 +149,29 @@ def _airflow_fan_write(payload, rep, href=None):
return None
# Confirmed via issue #56's second, properly-spaced round of diagnostics
# (two independent units, 60-90s apart per setting): /airflow/0's `speed` is
# a clean, monotonic 0-4 code across Auto/Sleep/Low/Medium/High, so it now
# backs a real ordered-speed fan (fan.py's LocalThingsAirflowFan, same
# SET_SPEED shape as the range hood's) instead of a read-only sensor --
# no named-preset table needed, since HA's percentage steps map onto the
# raw 0-4 code directly, the same way the range hood's numeric levels do.
# `direction` stays a plain diagnostic: every dump seen (both rounds, both
# units) reads 'Off' for it regardless of fan setting, so there's nothing
# confirmed to control there yet.
#
# Keyed 'airflow_fan', not 'fan' -- FAN below (bound to the shared
# /mode/vs/0 href) also uses 'fan', and BoundEntity's unique_id is built
# from key alone (entity.py's _key), not href. FAN and AIRFLOW_GENERIC are
# only *empirically* mutually exclusive (every dump seen has one board
# generation's shape or the other, never both), not architecturally
# enforced the way same-href caps are by _build()'s match_fn check -- a
# same key would collide if a future board ever reported both.
AIRFLOW_GENERIC = Capability(
href='/airflow/0',
href=HREF_AIRFLOW,
poll_tier='warm',
entities=(
FanDesc(key='fan', field='speed', write_fn=_airflow_fan_write),
FanDesc(key='airflow_fan', field='speed', write_fn=_airflow_fan_write),
SensorDesc(key='fan_direction', field='direction',
icon='mdi:rotate-3d-variant',
entity_category='diagnostic'),