refactor: share remote-control read between sensor and write guard, poll it warm
Move the on/off interpretation into a single remote_control_enabled() in registry/capabilities/common.py so the write-guard added in the previous commit can't silently drift from the Smart Control binary sensor's own reading of the same hrefs. Also promotes both /remotectrl hrefs to poll_tier='warm' so the coordinator's cached state backing that write guard doesn't lag up to a full 30s cold summary poll behind the device's actual toggle state.
This commit is contained in:
4 files changed
+48
-28
No files matched your search
@@ -13,8 +13,9 @@ from homeassistant.helpers import issue_registry as ir
|
||||
from custom_components.localthings.const import (
|
||||
CONF_HOST, DOMAIN, SUMMARY_INTERVAL_S,
|
||||
)
|
||||
from custom_components.localthings.coordinator import (
|
||||
LocalThingsCoordinator, _remote_control_disabled,
|
||||
from custom_components.localthings.coordinator import LocalThingsCoordinator
|
||||
from custom_components.localthings.registry.capabilities.common import (
|
||||
remote_control_enabled,
|
||||
)
|
||||
from custom_components.localthings.observe import MODE_OBSERVE, MODE_POLL, PUSH_HEALTH_WINDOW_S
|
||||
|
||||
@@ -639,36 +640,37 @@ async def test_write_marks_href_pending_before_post(
|
||||
assert coordinator._observe._settle_until.get('/test/vs/0') is not None
|
||||
|
||||
|
||||
class TestRemoteControlDisabled:
|
||||
"""_remote_control_disabled mirrors REMOTE_CONTROL_GENERIC/_VS_FALLBACK's
|
||||
OCF-standard-preferred read (registry/capabilities/common.py) directly
|
||||
on a raw resources snapshot."""
|
||||
class TestRemoteControlEnabled:
|
||||
"""remote_control_enabled (registry/capabilities/common.py) is the
|
||||
single source of truth for the /remotectrl on/off signal, shared by
|
||||
the Smart Control binary_sensor descriptors and the coordinator's
|
||||
write guard alike."""
|
||||
|
||||
def test_vs_fallback_href_true_is_enabled(self):
|
||||
resources = {'/remotectrl/vs/0': {'x.com.samsung.da.remoteControlEnabled': 'true'}}
|
||||
assert _remote_control_disabled(resources) is False
|
||||
assert remote_control_enabled(resources) is True
|
||||
|
||||
def test_vs_fallback_href_false_is_disabled(self):
|
||||
resources = {'/remotectrl/vs/0': {'x.com.samsung.da.remoteControlEnabled': 'false'}}
|
||||
assert _remote_control_disabled(resources) is True
|
||||
assert remote_control_enabled(resources) is False
|
||||
|
||||
def test_generic_href_true_is_enabled(self):
|
||||
resources = {'/remotectrl/0': {'value': True}}
|
||||
assert _remote_control_disabled(resources) is False
|
||||
assert remote_control_enabled(resources) is True
|
||||
|
||||
def test_generic_href_false_is_disabled(self):
|
||||
resources = {'/remotectrl/0': {'value': False}}
|
||||
assert _remote_control_disabled(resources) is True
|
||||
assert remote_control_enabled(resources) is False
|
||||
|
||||
def test_generic_href_wins_when_both_present(self):
|
||||
resources = {
|
||||
'/remotectrl/0': {'value': True},
|
||||
'/remotectrl/vs/0': {'x.com.samsung.da.remoteControlEnabled': 'false'},
|
||||
}
|
||||
assert _remote_control_disabled(resources) is False
|
||||
assert remote_control_enabled(resources) is True
|
||||
|
||||
def test_fails_open_when_capability_absent(self):
|
||||
assert _remote_control_disabled({}) is False
|
||||
def test_assumes_enabled_when_capability_absent(self):
|
||||
assert remote_control_enabled({}) is True
|
||||
|
||||
|
||||
async def test_send_command_blocked_when_remote_control_disabled(
|
||||
|
||||
@@ -84,6 +84,14 @@ class TestRemoteControlFallback:
|
||||
assert common.REMOTE_CONTROL_VS_FALLBACK.match_fn(
|
||||
{}, {'/remotectrl/0': {}, '/remotectrl/vs/0': {}}) is False
|
||||
|
||||
def test_polled_warm_so_write_gating_stays_fresh(self):
|
||||
"""coordinator.async_send_command blocks writes on this signal, so
|
||||
it can't sit in the default 'cold' tier (refreshed only once per
|
||||
30s summary poll) -- it needs the subscribe/subpoll cadence 'warm'
|
||||
and 'hot' hrefs get instead."""
|
||||
assert common.REMOTE_CONTROL_GENERIC.poll_tier == 'warm'
|
||||
assert common.REMOTE_CONTROL_VS_FALLBACK.poll_tier == 'warm'
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Energy meter. instantaneousPower clamps negatives to 0, but the constant
|
||||
|
||||
Reference in new issue