Merge remote-tracking branch 'origin/main' into claude/device-support-issue-88-dehumidifier
# Conflicts: # custom_components/localthings/registry/by_type/__init__.py # tests/test_by_type.py # tests/test_golden_regression.py
This commit is contained in:
14 files changed
+738
-9
No files matched your search
@@ -4,7 +4,7 @@ from typing import Optional
|
||||
from ._base import DeviceRegistry
|
||||
from . import (
|
||||
air_purifier, airconditioner, cooktop, dehumidifier, dishwasher, dryer,
|
||||
oven, range as _range, range_hood, refrigerator, washer,
|
||||
oven, range as _range, range_hood, refrigerator, washer, water_purifier,
|
||||
)
|
||||
|
||||
__all__ = [
|
||||
@@ -28,6 +28,7 @@ _REGISTRY_BY_KEY: dict[str, DeviceRegistry] = {
|
||||
'range_hood': range_hood.REGISTRY,
|
||||
'refrigerator': refrigerator.REGISTRY,
|
||||
'washer': washer.REGISTRY,
|
||||
'water_purifier': water_purifier.REGISTRY,
|
||||
}
|
||||
|
||||
|
||||
@@ -165,6 +166,10 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
model_identity = f'{model_num} {description}'.upper()
|
||||
if key is None and ('_COOKTOP' in model_identity or '_GB_CT_' in model_identity):
|
||||
key = 'cooktop'
|
||||
# Water purifiers (e.g. TP2X_WATERPURIFIER_20K, issue #90) report no
|
||||
# oneUiVersion and carry the 'WATERPURIFIER' board-family token.
|
||||
if key is None and 'WATERPURIFIER' in model_identity:
|
||||
key = 'water_purifier'
|
||||
if key is None and model_identity.startswith('AHD-'):
|
||||
key = 'range_hood'
|
||||
# Range/cooktop-oven combos (e.g. TP1X_DA-KS-RANGE-0102X, issue #44) --
|
||||
|
||||
@@ -1,11 +1,21 @@
|
||||
"""Cooktop device registry."""
|
||||
"""Gas cooktop device registry (NA9300K-class, PR #23).
|
||||
|
||||
Named 'gas_cooktop' (not 'cooktop') so its diagnostics/device-info label
|
||||
doesn't collide with the unrelated induction_cooktop family (issue #86,
|
||||
by_type/induction_cooktop.py) -- two different OCF surfaces that happen to
|
||||
share the English word "cooktop". The `_REGISTRY_BY_KEY['cooktop']` lookup
|
||||
key is unchanged: it's relied on by real devices reporting
|
||||
oneUiVersion "Cooktop" (for_device), the legacy ARTIK051 modelNum rule
|
||||
(for_device_by_model), and the resource-signature fallback
|
||||
(for_device_by_resources) alike.
|
||||
"""
|
||||
|
||||
from ..capabilities import common, cooktop, ignored
|
||||
from ._base import DeviceRegistry, _build
|
||||
|
||||
|
||||
REGISTRY = DeviceRegistry(
|
||||
name='cooktop',
|
||||
name='gas_cooktop',
|
||||
capabilities=_build([
|
||||
*ignored.IGNORED,
|
||||
cooktop.COOKTOP_POWER,
|
||||
|
||||
@@ -0,0 +1,18 @@
|
||||
"""Water-purifier device registry (Samsung TP2X_WATERPURIFIER-class, issue #90).
|
||||
"""
|
||||
from ..capabilities import common, ignored, water_purifier
|
||||
from ._base import DeviceRegistry, _build
|
||||
|
||||
REGISTRY = DeviceRegistry(
|
||||
name='water_purifier',
|
||||
capabilities=_build([
|
||||
*ignored.IGNORED,
|
||||
*common.UNIVERSAL,
|
||||
common.WATER_FILTER,
|
||||
water_purifier.DISPENSE,
|
||||
water_purifier.STATUS,
|
||||
water_purifier.FAVORITE_CAPACITY,
|
||||
water_purifier.LOCK,
|
||||
*water_purifier.COVERAGE,
|
||||
]),
|
||||
)
|
||||
@@ -0,0 +1,165 @@
|
||||
"""Capabilities for the Samsung water-purifier family (TP2X_WATERPURIFIER-class,
|
||||
issue #90, model TP2X_WATERPURIFIER_20K).
|
||||
|
||||
Resources verified against the issue #90 diagnostics dump.
|
||||
"""
|
||||
from datetime import datetime, timezone
|
||||
|
||||
from ..capability import Capability
|
||||
from ..entities import BinarySensorDesc, NumberDesc, SelectDesc, SensorDesc, SwitchDesc
|
||||
from .common import int_or_none
|
||||
|
||||
|
||||
def _parse_iso_utc(raw):
|
||||
"""Bare ISO datetime with no timezone field alongside it -- treated as
|
||||
UTC, matching this integration's convention for other bare ISO datetime
|
||||
fields (see washer.py's drum-clean-log comment)."""
|
||||
if not raw:
|
||||
return None
|
||||
try:
|
||||
return datetime.fromisoformat(raw).replace(tzinfo=timezone.utc)
|
||||
except ValueError:
|
||||
return None
|
||||
|
||||
|
||||
DISPENSE = Capability(
|
||||
href='/setting/waterpurifier/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SelectDesc(key='dispense_type', field='x.com.samsung.da.desiredType',
|
||||
icon='mdi:cup-water',
|
||||
options_field='x.com.samsung.da.supportedTypes',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['setting', 'waterpurifier', 'vs', '0'],
|
||||
{'x.com.samsung.da.desiredType': p})),
|
||||
# Only a handful of discrete temperatures are selectable (not a
|
||||
# continuous range) -- a select over the live-reported set, not a
|
||||
# number with invented bounds.
|
||||
SelectDesc(key='hot_water_temperature', field='x.com.samsung.da.tempDesiredHotWater',
|
||||
icon='mdi:thermometer',
|
||||
entity_category='config',
|
||||
options_field='x.com.samsung.da.supportedHotTemperatures',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['setting', 'waterpurifier', 'vs', '0'],
|
||||
{'x.com.samsung.da.tempDesiredHotWater': p})),
|
||||
# Bounds and step come live from the device's own
|
||||
# desiredCapacityRange/capacityResolution fields, not a hardcoded
|
||||
# constant -- see the adding-device-support skill's "never hard-code
|
||||
# the one dump's values" section. No unit is set: capacityUnit reads
|
||||
# "C" on this dump, which can't be right for a volume field, so per
|
||||
# the 'don't guess' rule the unit is left unset rather than assumed
|
||||
# to be mL.
|
||||
NumberDesc(key='dispense_capacity', field='x.com.samsung.da.desiredCapacity',
|
||||
icon='mdi:cup-water',
|
||||
value_fn=int_or_none,
|
||||
range_field='x.com.samsung.da.desiredCapacityRange',
|
||||
step_fn=lambda rep: int_or_none(
|
||||
rep.get('x.com.samsung.da.capacityResolution')) or 1,
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['setting', 'waterpurifier', 'vs', '0'],
|
||||
{'x.com.samsung.da.desiredCapacity': str(int(round(float(p))))})),
|
||||
BinarySensorDesc(key='pouring', field='x.com.samsung.da.pourStatus',
|
||||
icon='mdi:cup-water',
|
||||
value_fn=lambda v: v == 'On'),
|
||||
),
|
||||
)
|
||||
|
||||
STATUS = Capability(
|
||||
href='/status/waterpurifier/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SensorDesc(key='waterpurifier_status', field='x.com.samsung.da.status',
|
||||
icon='mdi:water-pump',
|
||||
entity_category='diagnostic'),
|
||||
BinarySensorDesc(key='filter_door_status', field='x.com.samsung.da.filterDoorStatus',
|
||||
device_class='door',
|
||||
entity_category='diagnostic',
|
||||
value_fn=lambda v: v == 'Open'),
|
||||
SensorDesc(key='sterilize_period', field='x.com.samsung.da.sterilizePeriod',
|
||||
icon='mdi:calendar-sync',
|
||||
entity_category='diagnostic'),
|
||||
SensorDesc(key='sterilize_run_time', field='x.com.samsung.da.sterilizeRunTime',
|
||||
icon='mdi:timer-outline',
|
||||
entity_category='diagnostic'),
|
||||
SensorDesc(key='sterilize_last_time', device_class='timestamp',
|
||||
entity_category='diagnostic',
|
||||
rep_fn=lambda rep: _parse_iso_utc(
|
||||
rep.get('x.com.samsung.da.sterilizeLastTime'))),
|
||||
SensorDesc(key='sterilize_plan_time', device_class='timestamp',
|
||||
entity_category='diagnostic',
|
||||
rep_fn=lambda rep: _parse_iso_utc(
|
||||
rep.get('x.com.samsung.da.sterilizePlanTime'))),
|
||||
SensorDesc(key='filter_clean_remain_time', field='x.com.samsung.da.filterCleanRemainTime',
|
||||
icon='mdi:timer-sand',
|
||||
entity_category='diagnostic'),
|
||||
),
|
||||
)
|
||||
|
||||
FAVORITE_CAPACITY = Capability(
|
||||
href='/favorite/capacity/vs/0',
|
||||
poll_tier='cold',
|
||||
entities=(
|
||||
SwitchDesc(key='favorite_capacity_enabled', field='x.com.samsung.da.switchCapacity',
|
||||
icon='mdi:star-outline',
|
||||
entity_category='config',
|
||||
value_fn=lambda v: v == 'On',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['favorite', 'capacity', 'vs', '0'],
|
||||
{'x.com.samsung.da.switchCapacity': 'On' if p == 'On' else 'Off'})),
|
||||
SelectDesc(key='favorite_capacity', field='x.com.samsung.da.defaultCapacity',
|
||||
icon='mdi:cup-water',
|
||||
entity_category='config',
|
||||
options_field='x.com.samsung.da.capacityList',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['favorite', 'capacity', 'vs', '0'],
|
||||
{'x.com.samsung.da.defaultCapacity': p})),
|
||||
),
|
||||
)
|
||||
|
||||
LOCK = Capability(
|
||||
href='/status/lock/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SwitchDesc(key='hotwater_lock', field='x.com.samsung.da.hotwaterLock',
|
||||
device_class='lock',
|
||||
entity_category='config',
|
||||
value_fn=lambda v: v != 'Unlocked',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['status', 'lock', 'vs', '0'],
|
||||
{'x.com.samsung.da.hotwaterLock': 'Locked' if p == 'On' else 'Unlocked'})),
|
||||
SwitchDesc(key='coldwater_lock', field='x.com.samsung.da.coldwaterLock',
|
||||
device_class='lock',
|
||||
entity_category='config',
|
||||
value_fn=lambda v: v != 'Unlocked',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['status', 'lock', 'vs', '0'],
|
||||
{'x.com.samsung.da.coldwaterLock': 'Locked' if p == 'On' else 'Unlocked'})),
|
||||
SwitchDesc(key='buzz_lock', field='x.com.samsung.da.buzzLock',
|
||||
device_class='lock',
|
||||
entity_category='config',
|
||||
value_fn=lambda v: v != 'Unlocked',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['status', 'lock', 'vs', '0'],
|
||||
{'x.com.samsung.da.buzzLock': 'Locked' if p == 'On' else 'Unlocked'})),
|
||||
),
|
||||
)
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Water-purifier-scoped coverage: hrefs with no user-actionable state or no
|
||||
# confirmed contract, following the 'don't guess' rule.
|
||||
# ---------------------------------------------------------------------------
|
||||
_WP_IGNORED = [
|
||||
# supportedModes carries a single opaque wizard-workflow token
|
||||
# ('HOMECARE_WIZARD_V2') and modes reports a completely different,
|
||||
# unrelated value ('WATERFILTER_DISABLE') not even present in
|
||||
# supportedModes -- internal plumbing, not a real user-facing mode
|
||||
# select. OCF-standard /mode/0 mirrors the same vendor resource but is
|
||||
# already covered by the global ignored.IGNORED (fridge's OCF-native
|
||||
# vacation-mode flag shares that href).
|
||||
'/mode/vs/0',
|
||||
# Static support-flags blob (automation.supported.modes/options) -- no
|
||||
# live "current automation setting" field to expose.
|
||||
'/automation/waterpurifier/vs/0',
|
||||
]
|
||||
|
||||
COVERAGE = [Capability(href=h) for h in _WP_IGNORED]
|
||||
Reference in new issue
Block a user