Add humidity/temperature sensors and horizontal swing for AC (issue #75)

Three gaps reported against an ARTIK051_PRAC_20K WindFree unit vs. the
SmartThings integration:

1. Missing WindFree/motion convenient-mode presets -- left alone here.
   PR #91 replaces climate.py's static _DEVICE_TO_PRESET table with a
   generic resolver that reads any preset code straight off the unit's
   own supportedModes, which already covers this (and more generically
   than a per-model dict would) -- adding one here would just conflict.

2. No horizontal oscillation: /wind/direction/vs/0's supportedModes
   includes Left_And_Right, which _DEVICE_TO_SWING had no mapping for.
   Add it to HA's standard 'horizontal' swing constant.

3. No standalone humidity/current-temperature sensors: the climate card
   already reads both internally, but nothing exposed them as entities
   for history/automations. Add CURRENT_TEMPERATURE (OCF
   /temperature/current/0) with a CURRENT_TEMPERATURE_VS vendor fallback
   (same match_fn-gated pair shape as common.py's POWER_GENERIC/
   POWER_VS_FALLBACK), and a HUMIDITY sensor reading /humidity/vs/0's
   fivepercentHumidity field -- the only one of the three
   humidity-shaped fields across /humidity/0 and /humidity/vs/0 that
   isn't permanently stuck at 0 on every dump seen.

Regenerates the five existing AC goldens (all pick up
current_temperature_c; most pick up humidity) and adds a dedicated
fixture from the issue's WindFree dump, whose /humidity/vs/0 actually
has live fivepercentHumidity data.
This commit is contained in:
Marc Billow committed 2026-07-27 00:33:35 +00:00
1 parent aff7647460
commit 3afbe6c6c1
15 files changed
+579 -3

No files matched your search

+51 -2
View File
@@ -114,11 +114,13 @@ def test_climate_write_targets():
def test_climate_consumed_hrefs_declared_as_coverage():
"""The climate-consumed and ambiguous hrefs are declared in the AC registry
(as no-entity coverage caps) so they don't leak as gaps -- but produce no
standalone entities."""
standalone entities. /temperature/current/0 and /temperatures/vs/0 are
NOT in this list -- CURRENT_TEMPERATURE / CURRENT_TEMPERATURE_VS give
those two real sensor entities (issue #75)."""
reg, _ = _ac()
for href in ('/power/0', '/power/vs/0', '/temperature/desired/0',
'/wind/strength/vs/0', '/mode/convenient/vs/0',
'/temperatures/vs/0', '/sensors/vs/0', '/humidity/0'):
'/sensors/vs/0', '/humidity/0'):
caps = reg.capabilities.get(href)
assert caps, href
assert all(c.entities == () for c in caps), href
@@ -257,3 +259,50 @@ def test_current_limit_is_read_only():
than a guessed writable control."""
for desc in airconditioner.CURRENT_LIMIT.entities:
assert getattr(desc, 'write_fn', None) is None
# ---------------------------------------------------------------------------
# WindFree unit (issue #75): same ARTIK051_PRAC_20K modelNum family as the
# original issue #17 fixture, but its /mode/convenient/vs/0 additionally
# supports Nano/NanoSleep/MotionDirect/MotionIndirect, /wind/direction/vs/0
# additionally supports Left_And_Right, and /humidity/vs/0's
# fivepercentHumidity is populated (unlike the all-zero original dump).
# ---------------------------------------------------------------------------
def _ac_windfree():
resources = _load_device('airconditioner_windfree')
info = resources['/information/vs/0']
reg = for_device_by_model(
info['x.com.samsung.da.modelNum'], info['x.com.samsung.da.description'],
)
return reg, resources
def test_windfree_no_unbound_hrefs():
reg, resources = _ac_windfree()
unbound = []
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
assert unbound == []
def test_windfree_humidity_and_temperature_sensors_present():
reg, resources = _ac_windfree()
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
state = flatten(bound, resources)
assert state['humidity'] == 42.0 # fivepercentHumidity, not the stuck humidity=0 field
assert state['current_temperature_c'] == 27.0
def test_current_temperature_vs_only_binds_when_ocf_href_absent():
"""CURRENT_TEMPERATURE_VS's match_fn must not double-bind alongside
CURRENT_TEMPERATURE when a device (like this one) reports both
/temperature/current/0 and /temperatures/vs/0."""
match = airconditioner.CURRENT_TEMPERATURE_VS.match_fn
assert match({}, {'/temperature/current/0': {}}) is False
assert match({}, {}) is True
def test_humidity_reads_five_percent_field_not_stuck_humidity_field():
desc = airconditioner.HUMIDITY.entities[0]
rep = {'x.com.samsung.da.humidity': '0', 'x.com.samsung.da.fivepercentHumidity': '42'}