Add humidity/temperature sensors and horizontal swing for AC (issue #75)
Three gaps reported against an ARTIK051_PRAC_20K WindFree unit vs. the SmartThings integration: 1. Missing WindFree/motion convenient-mode presets -- left alone here. PR #91 replaces climate.py's static _DEVICE_TO_PRESET table with a generic resolver that reads any preset code straight off the unit's own supportedModes, which already covers this (and more generically than a per-model dict would) -- adding one here would just conflict. 2. No horizontal oscillation: /wind/direction/vs/0's supportedModes includes Left_And_Right, which _DEVICE_TO_SWING had no mapping for. Add it to HA's standard 'horizontal' swing constant. 3. No standalone humidity/current-temperature sensors: the climate card already reads both internally, but nothing exposed them as entities for history/automations. Add CURRENT_TEMPERATURE (OCF /temperature/current/0) with a CURRENT_TEMPERATURE_VS vendor fallback (same match_fn-gated pair shape as common.py's POWER_GENERIC/ POWER_VS_FALLBACK), and a HUMIDITY sensor reading /humidity/vs/0's fivepercentHumidity field -- the only one of the three humidity-shaped fields across /humidity/0 and /humidity/vs/0 that isn't permanently stuck at 0 on every dump seen. Regenerates the five existing AC goldens (all pick up current_temperature_c; most pick up humidity) and adds a dedicated fixture from the issue's WindFree dump, whose /humidity/vs/0 actually has live fivepercentHumidity data.
This commit is contained in:
15 files changed
+579
-3
No files matched your search
@@ -114,11 +114,13 @@ def test_climate_write_targets():
|
||||
def test_climate_consumed_hrefs_declared_as_coverage():
|
||||
"""The climate-consumed and ambiguous hrefs are declared in the AC registry
|
||||
(as no-entity coverage caps) so they don't leak as gaps -- but produce no
|
||||
standalone entities."""
|
||||
standalone entities. /temperature/current/0 and /temperatures/vs/0 are
|
||||
NOT in this list -- CURRENT_TEMPERATURE / CURRENT_TEMPERATURE_VS give
|
||||
those two real sensor entities (issue #75)."""
|
||||
reg, _ = _ac()
|
||||
for href in ('/power/0', '/power/vs/0', '/temperature/desired/0',
|
||||
'/wind/strength/vs/0', '/mode/convenient/vs/0',
|
||||
'/temperatures/vs/0', '/sensors/vs/0', '/humidity/0'):
|
||||
'/sensors/vs/0', '/humidity/0'):
|
||||
caps = reg.capabilities.get(href)
|
||||
assert caps, href
|
||||
assert all(c.entities == () for c in caps), href
|
||||
@@ -257,3 +259,50 @@ def test_current_limit_is_read_only():
|
||||
than a guessed writable control."""
|
||||
for desc in airconditioner.CURRENT_LIMIT.entities:
|
||||
assert getattr(desc, 'write_fn', None) is None
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# WindFree unit (issue #75): same ARTIK051_PRAC_20K modelNum family as the
|
||||
# original issue #17 fixture, but its /mode/convenient/vs/0 additionally
|
||||
# supports Nano/NanoSleep/MotionDirect/MotionIndirect, /wind/direction/vs/0
|
||||
# additionally supports Left_And_Right, and /humidity/vs/0's
|
||||
# fivepercentHumidity is populated (unlike the all-zero original dump).
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
def _ac_windfree():
|
||||
resources = _load_device('airconditioner_windfree')
|
||||
info = resources['/information/vs/0']
|
||||
reg = for_device_by_model(
|
||||
info['x.com.samsung.da.modelNum'], info['x.com.samsung.da.description'],
|
||||
)
|
||||
return reg, resources
|
||||
|
||||
|
||||
def test_windfree_no_unbound_hrefs():
|
||||
reg, resources = _ac_windfree()
|
||||
unbound = []
|
||||
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
|
||||
assert unbound == []
|
||||
|
||||
|
||||
def test_windfree_humidity_and_temperature_sensors_present():
|
||||
reg, resources = _ac_windfree()
|
||||
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
|
||||
state = flatten(bound, resources)
|
||||
assert state['humidity'] == 42.0 # fivepercentHumidity, not the stuck humidity=0 field
|
||||
assert state['current_temperature_c'] == 27.0
|
||||
|
||||
|
||||
def test_current_temperature_vs_only_binds_when_ocf_href_absent():
|
||||
"""CURRENT_TEMPERATURE_VS's match_fn must not double-bind alongside
|
||||
CURRENT_TEMPERATURE when a device (like this one) reports both
|
||||
/temperature/current/0 and /temperatures/vs/0."""
|
||||
match = airconditioner.CURRENT_TEMPERATURE_VS.match_fn
|
||||
assert match({}, {'/temperature/current/0': {}}) is False
|
||||
assert match({}, {}) is True
|
||||
|
||||
|
||||
def test_humidity_reads_five_percent_field_not_stuck_humidity_field():
|
||||
desc = airconditioner.HUMIDITY.entities[0]
|
||||
rep = {'x.com.samsung.da.humidity': '0', 'x.com.samsung.da.fivepercentHumidity': '42'}
|
||||
assert desc.value_fn(rep.get(desc.field)) == 42.0
|
||||
Reference in new issue