Address independent review findings on the RAC finish-up branch
- Pin the FAN_ONLY reverse-write fallback to 'Wind' (the original single spelling) instead of letting it silently flip to 'Fan' just because 'Fan' was added second to the dict -- _device_code_for_hvac() resolves the code from a unit's own supportedModes first, so this dict is only a fallback for a unit reporting none at all, and that fallback shouldn't change behavior as an unintended side effect of insertion order. - Add direct tests for _preset_to_ha() (pure function, previously untested) and the FAN_ONLY fallback pin. - Cross-reference the AC family's inverted Light_On/Light_Off polarity against air_purifier.py's plain-polarity use of the same token name on the same resource name, so a future refactor doesn't assume they're the same thing. - Fix a one-column continuation-line misalignment and a stale PR-number reference in a comment.
This commit is contained in:
5 files changed
+50
-8
No files matched your search
@@ -71,9 +71,13 @@ _DEVICE_TO_HVAC: dict[str, HVACMode] = {
|
||||
# 'Fan' on others (e.g. TP1X_DA-AC-RAC-01011); both map to FAN_ONLY. The
|
||||
# reverse write can't rely on this map alone (two codes, one HA value) --
|
||||
# _device_code_for_hvac() resolves the code from the unit's own
|
||||
# supportedModes.
|
||||
'Wind': HVACMode.FAN_ONLY,
|
||||
# supportedModes, so this is only a fallback for a unit reporting no
|
||||
# supportedModes at all. 'Fan' is listed first so the {v: k} reverse
|
||||
# comprehension below has 'Wind' win that fallback (last-key-wins),
|
||||
# preserving the original single-spelling behavior rather than silently
|
||||
# flipping it when 'Fan' was added.
|
||||
'Fan': HVACMode.FAN_ONLY,
|
||||
'Wind': HVACMode.FAN_ONLY,
|
||||
# The device's 'Auto' is a single-setpoint "device decides" mode -> HA
|
||||
# HVACMode.AUTO (renders "Auto"). Not HEAT_COOL: that renders "Heat/cool"
|
||||
# and implies a two-setpoint heat+cool range these single-setpoint units
|
||||
|
||||
@@ -171,7 +171,7 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
# /otninformation/vs/0 ships no swVersionInfo block at all, so
|
||||
# oneUiVersion is empty.
|
||||
if key is None and ('_RAC_' in (model_num or '')
|
||||
or '-RAC-' in (model_num or '').upper()):
|
||||
or '-RAC-' in (model_num or '').upper()):
|
||||
key = 'airconditioner'
|
||||
# System air conditioners (multi-indoor-unit commercial installs, e.g.
|
||||
# A-CAWW-TP2-20-COMMON, issue #52) report no oneUiVersion either and
|
||||
|
||||
@@ -15,6 +15,13 @@ issue #56's follow-up (five diagnostics dumps captured with the physical unit
|
||||
set to Auto/Sleep/Low/Medium/High):
|
||||
Light_On / Light_Off -- a plain on/off flag; MODE below models it as a
|
||||
real switch, RMW-replacing just that one entry.
|
||||
NOT the same polarity as the AC family's own
|
||||
Light_On/Light_Off token on its own /mode/vs/0
|
||||
(airconditioner._display_light_on) -- that one is
|
||||
confirmed inverted (Light_Off means the panel is
|
||||
lit) on live hardware. Same token name, same
|
||||
resource name, different device type and
|
||||
opposite meaning -- don't unify them.
|
||||
Comode_Off -- read 'Off' on *every* one of the five dumps,
|
||||
including High/Low/Medium/Auto -- confirms this
|
||||
is NOT the fan-speed selector (ruling out the
|
||||
|
||||
Reference in new issue