Document the reconnect-timing change from smartthings-local's fail-fast fix
Answers a review callout on the 0.1.6 upgrade that wasn't actually addressed, only mentioned in a commit message: a dead reader now raises SessionClosedError (a ConnectionError) instead of hanging a request out to its timeout and surfacing as an ambiguous TimeoutError. Mechanically this was already routed correctly -- SessionClosedError isn't a TimeoutError, so _defer_reconnect_for's isinstance check already skips its multi-cycle tolerance for it -- but nothing recorded *why*, and the callout's whole point was that downstream (i.e. this repo) should hear about the resulting timing change explicitly, not infer it from the dependency bump. Before 0.1.6, a truly dead reader was indistinguishable here from a slow blockwise transfer: both could only ever surface as a TimeoutError, so _POLL_TIMEOUT_LIMIT's multi-cycle tolerance (~2 minutes at the default 30s interval) was the only thing standing between a genuinely dead session and a reconnect. Now that the library confirms reader death directly, that failure mode skips the tolerance and reconnects on the very first occurrence -- intended, and strictly faster recovery, but a real change in observed timing worth calling out for anyone correlating reconnect-log cadence with device behavior. - _poll_once, _defer_reconnect_for, and the _POLL_TIMEOUT_LIMIT comment now say so directly, cross-referencing each other. - README's "Known device behavior" section gets a paragraph so this isn't only visible to someone reading the coordinator's source. - Two new unit tests pin the distinction directly: _defer_reconnect_for(SessionClosedError()) is False (no tolerance), while SessionTimeoutError keeps the existing _POLL_TIMEOUT_LIMIT tolerance -- so a future change can't quietly merge the two paths back together. Full suite (1523 tests), ruff, and ty pass.
This commit is contained in:
1 parent
f949ff04c2
commit
74bdc04f56
3 files changed
+58
-2
No files matched your search
@@ -268,6 +268,8 @@ Samsung's firmware occasionally drops the DTLS session briefly — this is norma
|
||||
|
||||
If reconnects become persistent (more than a handful per minute), something's actually wrong. Check the appliance's Wi-Fi link first, then look for a competing DTLS client on the LAN — only one active session per appliance is allowed at a time.
|
||||
|
||||
Reconnect *timing* depends on how confidently the drop was detected. An ambiguous failure — one block's ACK on the summary poll came back late, which doesn't by itself prove the session is dead — is tolerated for a few consecutive poll cycles (worst case ~2 minutes at the default 30s interval) before the integration gives up and reconnects, so one slow transfer can't tear down a working push subscription. A confirmed dead connection skips that tolerance and reconnects immediately: `smartthings-local` (>= 0.1.6) detects its own reader thread exiting and raises a distinct error for it, rather than the ambiguous timeout that failure used to produce on older library versions. So you may see a reconnect log line appear sooner than that old ~2-minute worst case for a session that's actually gone — that's the fast path working as intended, not a new source of flapping.
|
||||
|
||||
Deregistering a device in SmartThings causes a reset of its network settings as soon as it accesses Samsung's servers, dropping it off Wi-Fi until it's re-onboarded through the SmartThings app. As such, consider keeping devices registered even if egress-blocked, to avoid them resetting upon brief internet access.
|
||||
|
||||
### Multi-subdevice ("2-in-1") air conditioner systems
|
||||
|
||||
Reference in new issue