Fix ARTIK051_DONGLE_REF freezer type detection and door sensor (issue #77)
RZ32M713EWW/EE (an ARTIK051-dongle standalone freezer) reports no
oneUiVersion and a pipe-delimited modelNum
('ARTIK051_DONGLE_REF|<rest>') -- REF is the last underscore segment
before the pipe, not wrapped in underscores on both sides like the
'..._REF_...' shape for_device_by_model's substring check expected, so
the device fell through to 'unknown' with only common capabilities:
no door sensor, no temperature sensors, nothing fridge-specific.
Replace the substring check with a segment-based one
(_model_num_segments splits the pipe-delimited prefix on '_') that
catches both shapes. Same root cause, same fix, and same device family
independently reported and root-caused in issue #83 (which also covers
two further bugs -- config-flow/coordinator serial collisions on a
second symptom of this firmware, 'Nothing(SVC)' as a literal serial --
not needed here since this reporter has a single unit; left for #83).
Once routed to the refrigerator registry, fridge.py's existing pattern
capabilities pick up /temperature/current/freezer/0 and
/temperature/desired/freezer/0 for free -- they were never the actual
problem, just unreachable under the 'unknown' fallback (which never
tries pattern capabilities at all). The door sensor needed one more
fix: /door/onedoorfreezer/vs/0 reports the vendor-prefixed
x.com.samsung.da.openState, not the bare openState DOOR_GENERIC read,
so the entity existed but stayed permanently unavailable. Check both
field names via rep_fn.
This commit is contained in:
7 files changed
+348
-4
No files matched your search
@@ -166,6 +166,27 @@ def test_registry_reproduces_golden_state_keys_for_artik051_ref_17k():
|
||||
)
|
||||
|
||||
|
||||
def test_registry_reproduces_golden_state_keys_for_artik051_dongle_ref():
|
||||
"""ARTIK051_DONGLE_REF standalone freezer (issues #77/#83) -- reports no
|
||||
oneUiVersion and a pipe-delimited modelNum ('..._DONGLE_REF|<rest>')
|
||||
that the old '_REF_' substring check missed entirely; resolved via the
|
||||
segment-based check in for_device_by_model. Its door
|
||||
(/door/onedoorfreezer/vs/0) and temperature
|
||||
(/temperature/{current,desired}/freezer/0) hrefs only bind through
|
||||
fridge.py's pattern capabilities, which the 'unknown' fallback never
|
||||
tries -- so this also regression-tests that those resources bind at
|
||||
all once routed to the right registry."""
|
||||
from tests.conftest import _load_device
|
||||
resources = _load_device('refrigerator_artik051_dongle_ref')
|
||||
golden = json.loads((GOLDEN / 'refrigerator_artik051_dongle_ref.json').read_text())
|
||||
state_keys = _new_state_keys('refrigerator_artik051_dongle_ref', resources)
|
||||
assert set(state_keys) == set(golden['state_keys']), (
|
||||
f"state_keys mismatch:\n"
|
||||
f" extra: {sorted(set(state_keys) - set(golden['state_keys']))}\n"
|
||||
f" missing: {sorted(set(golden['state_keys']) - set(state_keys))}"
|
||||
)
|
||||
|
||||
|
||||
def test_registry_reproduces_golden_state_keys_for_tp2x_ref_20k():
|
||||
"""TP2X_REF_20K -- CV_FDR_-prefixed flex zone (issue #32) plus the extra
|
||||
energy fields (cumulativeConsumption/monthlyConsumption/
|
||||
|
||||
Reference in new issue
Block a user