Conflict was purely additive: both sides appended golden-regression tests at the same point in the file, and each side's last test shared the single trailing assert block. Kept every test from both sides, each with its own copy of that assert. One real semantic merge on top of that. #136 (on main) remodelled the legacy ARTIK051 board's beep from a buzzer_volume Number to a beep Switch, and HJcom's ARTIK051_DONGLE_FAC_18K is exactly that board generation (is_legacy_board -> True), so its golden -- written before that change existed -- still expected buzzer_volume. Regenerated it: buzzer_volume/unit1_buzzer_volume -> beep/unit1_beep on the master and the second indoor unit alike, with nothing else moving and still no unit2_ keys. That is main's intended behavior reaching the sub-unit for free, which is the point of binding siblings through the same registry. 967 passing. Re-ran the corpus-wide unique_id audit over all 57 fixtures (main added five this branch had never seen): no collisions within a platform.
This commit is contained in:
38 files changed
+2965
-107
No files matched your search
@@ -194,7 +194,17 @@ def _find_live_ports(host: str, ports: list[int], timeout: float) -> list[int]:
|
||||
except OSError:
|
||||
pass
|
||||
|
||||
return _order_candidates(live)
|
||||
# The sweep's ICMP-based verdict isn't reliable on every network path --
|
||||
# issue #192 captured a segregated-VLAN device where it called three
|
||||
# ports live that a concurrent nmap scan showed as closed, while the
|
||||
# port nmap found genuinely open|filtered (49154, one of our historically
|
||||
# confirmed ports) never showed up as live at all. Rather than trust a
|
||||
# wrong "not live" verdict on a port we already have strong prior
|
||||
# evidence for, always give the historically-confirmed ports a real
|
||||
# handshake attempt too. Bounded cost: at most len(PREFERRED_PROBE_PORTS)
|
||||
# extra handshakes, only when the sweep disagrees with the prior.
|
||||
rescued = [p for p in PREFERRED_PROBE_PORTS if p in ports and p not in live]
|
||||
return _order_candidates(live + rescued)
|
||||
|
||||
|
||||
def _is_placeholder_serial(serial: str) -> bool:
|
||||
@@ -238,14 +248,13 @@ def _probe_and_validate(host: str, ca_cert_pem: str, ca_key_pem: str) -> dict:
|
||||
candidates = _find_live_ports(
|
||||
host, PROBE_PORT_RANGE, LIVENESS_PROBE_TIMEOUT_S
|
||||
)
|
||||
if not candidates:
|
||||
# Every port in the range actively refused: there is no DTLS/CoAP
|
||||
# listener on this host, so a handshake can't succeed. Fail now with a
|
||||
# clear message instead of retrying doomed ports.
|
||||
raise CannotConnect(
|
||||
f"no live DTLS port found on {host} "
|
||||
f"in {PROBE_PORT_RANGE[0]}-{PROBE_PORT_RANGE[-1]}"
|
||||
)
|
||||
# No early "every port refused" fast-fail here: _find_live_ports always
|
||||
# rescues PREFERRED_PROBE_PORTS (issue #192), so candidates is never
|
||||
# empty as long as that table is non-empty and within PROBE_PORT_RANGE --
|
||||
# both true today, which made this branch permanently unreachable. A
|
||||
# genuinely dead host now fails via the handshake loop's own error below,
|
||||
# which carries the actual per-port timeout/refusal reason instead of a
|
||||
# generic "no live port found" message.
|
||||
_LOGGER.debug("Live DTLS port candidates on %s: %s", host, candidates)
|
||||
|
||||
last_exc = None
|
||||
|
||||
@@ -75,17 +75,24 @@ _BOARD_TOKEN_TO_KEY: dict[str, str] = {
|
||||
# Air conditioners. Every one of these is a distinct board family with
|
||||
# the same resource surface: room (issues #37, #91), package, Korean
|
||||
# (#136), window (#87), 2-in-1 floor+wall (#150, #153), system/commercial
|
||||
# (#52), and ARA-WW wall-mount (#115, #116, #117, #120).
|
||||
# (#52), cassette (#191), and ARA-WW wall-mount (#115, #116, #117, #120).
|
||||
'RAC': 'airconditioner',
|
||||
'PRAC': 'airconditioner',
|
||||
'KRAC': 'airconditioner',
|
||||
'WAC': 'airconditioner',
|
||||
'FAC': 'airconditioner',
|
||||
'CAWW': 'airconditioner',
|
||||
'CAC': 'airconditioner', # issue #191 -- TP1X_DA-AC-CAC-01001_0000
|
||||
'ARA': 'airconditioner',
|
||||
'DHM': 'dehumidifier', # issue #88 -- target humidity, no climate
|
||||
'TVTL': 'air_purifier', # issue #56 (ARTIK051)
|
||||
'VTWW': 'air_purifier', # issue #151 (BESPOKE Cube Air)
|
||||
'AVT': 'air_purifier', # issue #190 -- AVT-WW-TP1-23-AXX500, a
|
||||
# next-gen BESPOKE Cube Air board; same
|
||||
# lineage as VTWW above but the '-WW-'
|
||||
# delimiter now falls one letter to the
|
||||
# left ('A-VTWW-' -> 'AVT-WW-'), splitting
|
||||
# into a token the existing entry can't see
|
||||
'AIR': 'air_purifier', # issue #130 (TP1X_DA-AC-AIR)
|
||||
'WATERPURIFIER': 'water_purifier', # issue #90
|
||||
'ADW': 'dishwasher',
|
||||
|
||||
@@ -16,6 +16,11 @@ match_fn discriminators that keep them from colliding):
|
||||
token, added for it. Its fan
|
||||
is WIND_STRENGTH_FAN on /wind/strength/vs/0 rather than FAN on
|
||||
/mode/vs/0 -- see that capability's comment.
|
||||
- AVT-WW-TP1-23-class (issue #190). A next-gen board in the same VTWW
|
||||
lineage, resolved via its own 'AVT' board token since the '-WW-' delimiter
|
||||
falls one letter to the left of 'VTWW's whole-token spelling. Same
|
||||
resource surface as A-VTWW-TP2-21-COMMON above; no new capabilities
|
||||
needed.
|
||||
|
||||
Reuses dishwasher.DIAGNOSIS for /diagnosis/vs/0 (identical field/write
|
||||
contract).
|
||||
|
||||
@@ -7,6 +7,13 @@ this registry includes *common.UNIVERSAL but deliberately NOT common.POWER --
|
||||
on/off is the climate entity's HVACMode.OFF / TURN_ON/OFF. See common.POWER's
|
||||
own comment in capabilities/common.py for why it's excluded.
|
||||
|
||||
common.ENERGY_METER itself is also excluded from UNIVERSAL here, replaced by
|
||||
the ENERGY_METER_GENERIC/ENERGY_METER_LEGACY pair -- the legacy ARTIK051 board
|
||||
generation (issue #193) reports cumulativePower in a different unit than
|
||||
every other AC family, so this registry needs two mutually-exclusive variants
|
||||
of that one capability instead of the single shared one every other registry
|
||||
uses unconditionally.
|
||||
|
||||
Reuses dishwasher.DIAGNOSIS for /diagnosis/vs/0.
|
||||
"""
|
||||
from ..capabilities import airconditioner, common, dishwasher, ignored
|
||||
@@ -16,7 +23,9 @@ REGISTRY = DeviceRegistry(
|
||||
name='airconditioner',
|
||||
capabilities=_build([
|
||||
*ignored.IGNORED,
|
||||
*common.UNIVERSAL,
|
||||
*[c for c in common.UNIVERSAL if c is not common.ENERGY_METER],
|
||||
airconditioner.ENERGY_METER_GENERIC,
|
||||
airconditioner.ENERGY_METER_LEGACY,
|
||||
dishwasher.DIAGNOSIS,
|
||||
airconditioner.CLIMATE,
|
||||
airconditioner.AIR_PURIFY,
|
||||
|
||||
@@ -25,6 +25,7 @@ REGISTRY = DeviceRegistry(
|
||||
fridge.DEFROST_DELAY,
|
||||
fridge.DEFROST_DELAY_NATIVE_DUPLICATE,
|
||||
fridge.DEFROST_BLOCK_STATUS,
|
||||
fridge.DEFINITE_TEMPERATURE_COOLER,
|
||||
fridge.DOORS_FALLBACK,
|
||||
fridge.TEMPERATURES_FALLBACK,
|
||||
fridge.ICEMAKER_STATUS_FALLBACK,
|
||||
|
||||
@@ -14,10 +14,13 @@ None of these caps may go into the global `ALL`/`CAPABILITIES`: `/mode/vs/0`,
|
||||
different schema (see capabilities/__init__.py). They live only in the AC
|
||||
by_type registry.
|
||||
"""
|
||||
from dataclasses import replace
|
||||
|
||||
from ..capability import Capability
|
||||
from ..entities import (
|
||||
BinarySensorDesc, ClimateDesc, NumberDesc, SelectDesc, SensorDesc, SwitchDesc,
|
||||
)
|
||||
from . import common
|
||||
from .common import filter_usage_percent, normalize_temp_unit
|
||||
from .laundry import option_write
|
||||
|
||||
@@ -285,17 +288,64 @@ def _option_token(rep, prefix):
|
||||
def is_legacy_board(resources):
|
||||
"""True for the board generation whose airflow lives in /airflow/vs/0.
|
||||
|
||||
Newer families carry several of the same option tokens (Volume, Sleep,
|
||||
OutdoorTemp, Autoclean) *alongside* dedicated resources for those settings,
|
||||
so an ungated token entity would either duplicate an existing one or apply a
|
||||
scale calibrated elsewhere. Every AC dump on record has one shape or the
|
||||
other: /airflow/vs/0 with no /wind/* at all, or /wind/strength/vs/0 with no
|
||||
/airflow/vs/0. Same test as climate.py's _legacy_airflow(), so the entities
|
||||
below and the climate entity can never disagree about the generation.
|
||||
Newer families carry several of the same option tokens (Sleep, OutdoorTemp,
|
||||
Autoclean) *alongside* dedicated resources for those settings, so an
|
||||
ungated token entity would either duplicate an existing one or apply a
|
||||
scale calibrated elsewhere. (Volume used to be in this list too, back when
|
||||
it had its own gated buzzer_volume Number for this board generation --
|
||||
issue #136 replaced that with the unified 'beep' switch, which applies
|
||||
across every generation and isn't gated here at all.) Every AC dump on
|
||||
record has one shape or the other: /airflow/vs/0 with no /wind/* at all,
|
||||
or /wind/strength/vs/0 with no /airflow/vs/0. Same test as climate.py's
|
||||
_legacy_airflow(), so the entities below and the climate entity can never
|
||||
disagree about the generation.
|
||||
"""
|
||||
return HREF_AIRFLOW in resources and HREF_WIND_STRENGTH not in resources
|
||||
|
||||
|
||||
# This legacy ARTIK051 board generation (issue #193, model AR12NXWXCWKNEU /
|
||||
# ARTIK051_KRAC_18K) reports /energy/consumption/vs/0's cumulativePower in
|
||||
# centiwatt-hours -- raw value 100x the plain Wh every other AC board family
|
||||
# (and common.wh_to_kwh's assumed unit) reports. Confirmed against the
|
||||
# reporter's own SmartThings-app reading: raw '117430000' vs the app's
|
||||
# authoritative 1,174.30 kWh is exactly a /100000 factor (i.e. /100 on top of
|
||||
# wh_to_kwh's own /1000), not wh_to_kwh's plain /1000 alone. No other field in
|
||||
# ENERGY_METER's entities is present on this board's dump, so only
|
||||
# 'energy_kwh' needs a replacement value_fn here; the rest pass through
|
||||
# unchanged in case a future legacy dump ever reports them.
|
||||
def _legacy_cumulative_power_kwh(v):
|
||||
# float, not _int -- matches common.wh_to_kwh's own numeric parsing
|
||||
# (float via _num) rather than this module's integer-only _int, so a
|
||||
# decimal-formatted reading doesn't raise and silently go 'unknown'.
|
||||
try:
|
||||
n = float(v)
|
||||
except (TypeError, ValueError):
|
||||
return None
|
||||
return round(n / 100000.0, 2)
|
||||
|
||||
|
||||
ENERGY_METER_LEGACY = replace(
|
||||
common.ENERGY_METER,
|
||||
match_fn=lambda rep, resources: is_legacy_board(resources),
|
||||
entities=tuple(
|
||||
replace(e, value_fn=_legacy_cumulative_power_kwh)
|
||||
if e.key == 'energy_kwh' else e
|
||||
for e in common.ENERGY_METER.entities
|
||||
),
|
||||
)
|
||||
|
||||
# The non-legacy counterpart to ENERGY_METER_LEGACY above -- identical to
|
||||
# common.ENERGY_METER, just excluding the legacy board generation so the two
|
||||
# capabilities can share /energy/consumption/vs/0 in this registry without
|
||||
# the 'multiple caps need a discriminator' build check tripping (common.
|
||||
# ENERGY_METER itself has no match_fn, since every *other* registry includes
|
||||
# it unconditionally and alone).
|
||||
ENERGY_METER_GENERIC = replace(
|
||||
common.ENERGY_METER,
|
||||
match_fn=lambda rep, resources: not is_legacy_board(resources),
|
||||
)
|
||||
|
||||
|
||||
def _has_option_token(prefix):
|
||||
return lambda rep, resources: (
|
||||
is_legacy_board(resources) and _option_token(rep, prefix) is not None)
|
||||
@@ -445,14 +495,19 @@ CLIMATE = Capability(
|
||||
icon='mdi:led-on', entity_category='config'),
|
||||
# Beep on/off from the `Volume_*` option token (Volume_Mute/Volume_100).
|
||||
# Single-token option_write; a full options RMW reverts on ARTIK051_PRAC.
|
||||
# Gated off the legacy ARTIK051 board generation (see is_legacy_board):
|
||||
# that generation's own Volume_ token is already modeled as the
|
||||
# buzzer_volume Number below, and both reading the same options[] slot
|
||||
# into two entities would be redundant.
|
||||
#
|
||||
# Applies uniformly across board generations, including legacy
|
||||
# ARTIK051 boards -- issue #136: this token was originally modeled as
|
||||
# a 0-100 buzzer_volume Number for legacy boards on the assumption it
|
||||
# was a real graduated volume level, but every unit confirmed on
|
||||
# hardware (three units across two reporters) only ever carries
|
||||
# Volume_100 or Volume_Mute, never an intermediate value, and the
|
||||
# Number's write path (a plain integer string) could never produce
|
||||
# the literal 'Mute' token needed to actually turn it off -- writing
|
||||
# '0' is simply not a token this firmware recognizes. A switch is
|
||||
# both the correct model and the actual fix.
|
||||
SwitchDesc(key='beep', rep_fn=_beep_on,
|
||||
exists_fn=lambda rep, resources: (
|
||||
not is_legacy_board(resources)
|
||||
and _option_token(rep, 'Volume') is not None),
|
||||
exists_fn=lambda rep, resources: _option_token(rep, 'Volume') is not None,
|
||||
write_fn=_beep_write,
|
||||
icon='mdi:volume-high', entity_category='config'),
|
||||
# Tropical night mode level (0-16) from the `Sleep_<N>` option token.
|
||||
@@ -498,11 +553,6 @@ CLIMATE = Capability(
|
||||
exists_fn=_has_option_token('AirMonitoring'),
|
||||
write_fn=_option_switch_write('AirMonitoring'),
|
||||
icon='mdi:air-filter', entity_category='config'),
|
||||
NumberDesc(key='buzzer_volume', rep_fn=_option_token_num('Volume'),
|
||||
exists_fn=_has_option_token('Volume'),
|
||||
write_fn=_option_number_write('Volume'),
|
||||
native_min=0, native_max=100, step=10,
|
||||
icon='mdi:volume-high', entity_category='config'),
|
||||
# "Good Sleep" timer. 0 = off; the upper bound is a guess (the token
|
||||
# carries no range hint and only 0 has been observed on hardware), so a
|
||||
# write above 0 is unverified.
|
||||
|
||||
@@ -259,6 +259,12 @@ def sensor_item_value(items, sensor_type, index=0):
|
||||
|
||||
POWER_GENERIC = Capability(
|
||||
href='/power/0',
|
||||
# Neither href of this pair carried a poll_tier before (issue #56's
|
||||
# follow-up), so power state only ever refreshed on the once-per-30s
|
||||
# summary poll instead of the subscribe/subpoll cadence 'warm' and 'hot'
|
||||
# hrefs get -- the same "signal drives real-time state, but sat in the
|
||||
# slow default tier" gap as REMOTE_CONTROL_GENERIC/VS_FALLBACK above.
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
# Writable when firmware allows remote power; otherwise a read-only
|
||||
# binary_sensor with the same key keeps HA state without a dead switch.
|
||||
@@ -277,6 +283,7 @@ POWER_GENERIC = Capability(
|
||||
POWER_VS_FALLBACK = Capability(
|
||||
href='/power/vs/0',
|
||||
match_fn=lambda rep, resources: '/power/0' not in resources,
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SwitchDesc(key='power_switch', field='x.com.samsung.da.power',
|
||||
value_fn=lambda v: v == 'On',
|
||||
@@ -604,15 +611,22 @@ SELF_CHECK = Capability(
|
||||
# level: 2 of 6 families confirmed, blanket-added everywhere else).
|
||||
#
|
||||
# POWER is kept separate -- airconditioner is the one family that opts out
|
||||
# of it. Canonical reason (see by_type/airconditioner.py and its test for
|
||||
# pointers back here, not restatements): AC's climate entity already owns
|
||||
# /power/0 and /power/vs/0 via bare, no-entity Capability objects
|
||||
# (airconditioner.COVERAGE), and a second, real POWER_GENERIC/
|
||||
# of it entirely. Canonical reason (see by_type/airconditioner.py and its
|
||||
# test for pointers back here, not restatements): AC's climate entity
|
||||
# already owns /power/0 and /power/vs/0 via bare, no-entity Capability
|
||||
# objects (airconditioner.COVERAGE), and a second, real POWER_GENERIC/
|
||||
# POWER_VS_FALLBACK cap on the same href would make _build() raise (a href
|
||||
# with >1 cap must have every cap discriminated by rt_filter/match_fn, and
|
||||
# the bare COVERAGE cap has neither). Kids-lock/remote-control don't have
|
||||
# this conflict -- no AC dump has ever reported those hrefs -- so they stay
|
||||
# in UNIVERSAL.
|
||||
#
|
||||
# Airconditioner also partially opts out of UNIVERSAL itself, not just
|
||||
# POWER: issue #193 needs ENERGY_METER's cumulativePower scale to differ by
|
||||
# board generation, so by_type/airconditioner.py excludes just that one
|
||||
# member (`*[c for c in common.UNIVERSAL if c is not common.ENERGY_METER]`)
|
||||
# and substitutes airconditioner.ENERGY_METER_GENERIC/ENERGY_METER_LEGACY in
|
||||
# its place -- every other registry still unpacks UNIVERSAL wholesale.
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
UNIVERSAL = (
|
||||
|
||||
@@ -108,6 +108,37 @@ TEMP_SETPOINT = Capability(
|
||||
),
|
||||
)
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Discrete cooler setpoint (issue #186) -- some single-door ("cooler only")
|
||||
# fridges report no /temperature/current|desired/* pair at all (this href
|
||||
# doesn't match TEMP_CURRENT_GENERIC/TEMP_SETPOINT's '/temperature/current/'
|
||||
# or '/temperature/desired/' prefixes), only this one vendor resource that
|
||||
# bundles the live desired value together with the *specific* values the
|
||||
# unit accepts. That supportedList (e.g. ['1','2','3','4','7'] on the issue
|
||||
# #186 dump) is not a contiguous range -- 5 and 6 genuinely aren't valid
|
||||
# setpoints on this model -- so a NumberDesc with a min/max/step would let a
|
||||
# user pick an unsupported value; modeled as a select reading its own live
|
||||
# options list instead, same shape as BEVERAGE_ZONE/PANTRY_ZONE above.
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
def _definite_cooler_write(p, rep, href=None):
|
||||
return (['temperature', 'definite', 'cooler', 'vs', '0'],
|
||||
{'x.com.samsung.da.definite.desired': p})
|
||||
|
||||
|
||||
DEFINITE_TEMPERATURE_COOLER = Capability(
|
||||
href='/temperature/definite/cooler/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SelectDesc(key='cooler_temperature_setpoint',
|
||||
field='x.com.samsung.da.definite.desired',
|
||||
icon='mdi:thermometer',
|
||||
entity_category='config',
|
||||
options_field='x.com.samsung.da.definite.supportedList',
|
||||
write_fn=_definite_cooler_write),
|
||||
),
|
||||
)
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Icemaker nighttime quiet mode
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
@@ -24,6 +24,7 @@ but is effectively read-only in practice.
|
||||
"""
|
||||
from datetime import datetime, timezone, timedelta
|
||||
|
||||
from ..batch import is_stub_rep
|
||||
from ..capability import Capability
|
||||
from ..entities import (
|
||||
BinarySensorDesc, NumberDesc, SelectDesc, SensorDesc, SwitchDesc,
|
||||
@@ -130,6 +131,28 @@ def _option_value(options, prefix):
|
||||
return None
|
||||
|
||||
|
||||
def _has_option(prefix):
|
||||
"""exists_fn for an options-array switch: bind only when the device's own
|
||||
options[] actually carries a `<prefix>_<value>` token.
|
||||
|
||||
fast_preheat/natural_steam were shipped unconditionally (no exists_fn) as
|
||||
an unverified guess (see module docstring) -- issue #183's dump (model
|
||||
NE6516A) reports neither `fastpreheat_*` nor `NaturalSteam_*` in its
|
||||
options[] at all, so both switches were phantom controls: always read as
|
||||
off, and toggling them wrote a token the firmware never recognized in
|
||||
the first place, hence "does not appear to do anything."
|
||||
|
||||
`is_stub_rep(rep) or` keeps the same stub carve-out as cooktop.py's
|
||||
identical per-token exists_fn on its own options[]-array href: a stub
|
||||
/device/0 seed rep (not yet sub-polled) has no options[] at all, and
|
||||
without this an entity whose token is genuinely present would never get
|
||||
a first chance to bind, since exists_fn runs before that first real
|
||||
fetch lands.
|
||||
"""
|
||||
return lambda rep, resources: is_stub_rep(rep) or _option_value(
|
||||
rep.get('x.com.samsung.da.options'), prefix) is not None
|
||||
|
||||
|
||||
def _option_write(prefix, new_value):
|
||||
"""A one-token x.com.samsung.da.options write, mirroring
|
||||
laundry.option_write. NOT independently confirmed on an oven -- issue
|
||||
@@ -199,44 +222,19 @@ def _oven_mode_write(p, rep, href=None):
|
||||
return ['mode', 'vs', '0'], {'x.com.samsung.da.modes': [p]}
|
||||
|
||||
|
||||
def _lamp_write(p, rep, href=None):
|
||||
if p not in ('On', 'Off'):
|
||||
return None
|
||||
if not rep.get('x.com.samsung.da.options'):
|
||||
return None
|
||||
return ['mode', 'vs', '0'], {
|
||||
'x.com.samsung.da.options': _option_write('UpperLamp', p),
|
||||
}
|
||||
|
||||
|
||||
def _sound_write(p, rep, href=None):
|
||||
if p not in ('On', 'Off'):
|
||||
return None
|
||||
if not rep.get('x.com.samsung.da.options'):
|
||||
return None
|
||||
return ['mode', 'vs', '0'], {
|
||||
'x.com.samsung.da.options': _option_write('Sound', p),
|
||||
}
|
||||
|
||||
|
||||
def _fastpreheat_write(p, rep, href=None):
|
||||
if p not in ('On', 'Off'):
|
||||
return None
|
||||
if not rep.get('x.com.samsung.da.options'):
|
||||
return None
|
||||
return ['mode', 'vs', '0'], {
|
||||
'x.com.samsung.da.options': _option_write('fastpreheat', p),
|
||||
}
|
||||
|
||||
|
||||
def _naturalsteam_write(p, rep, href=None):
|
||||
if p not in ('On', 'Off'):
|
||||
return None
|
||||
if not rep.get('x.com.samsung.da.options'):
|
||||
return None
|
||||
return ['mode', 'vs', '0'], {
|
||||
'x.com.samsung.da.options': _option_write('NaturalSteam', p),
|
||||
}
|
||||
def _option_switch_write(prefix):
|
||||
"""Factory for a single-token on/off options-array write -- lamp, sound,
|
||||
fast_preheat, natural_steam, energy_saving, and cooktop_on_alert were all
|
||||
a byte-for-byte copy of this same shape, one per prefix."""
|
||||
def write(p, rep, href=None):
|
||||
if p not in ('On', 'Off'):
|
||||
return None
|
||||
if not rep.get('x.com.samsung.da.options'):
|
||||
return None
|
||||
return ['mode', 'vs', '0'], {
|
||||
'x.com.samsung.da.options': _option_write(prefix, p),
|
||||
}
|
||||
return write
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
@@ -377,19 +375,38 @@ OVEN_MODE = Capability(
|
||||
SwitchDesc(key='lamp', field='x.com.samsung.da.options',
|
||||
icon='mdi:track-light',
|
||||
value_fn=lambda opts: _option_value(opts, 'UpperLamp') == 'On',
|
||||
write_fn=_lamp_write),
|
||||
write_fn=_option_switch_write('UpperLamp')),
|
||||
SwitchDesc(key='sound', field='x.com.samsung.da.options',
|
||||
icon='mdi:volume-high',
|
||||
entity_category='config',
|
||||
value_fn=lambda opts: _option_value(opts, 'Sound') == 'On',
|
||||
write_fn=_sound_write),
|
||||
write_fn=_option_switch_write('Sound')),
|
||||
SwitchDesc(key='fast_preheat', field='x.com.samsung.da.options',
|
||||
icon='mdi:fire',
|
||||
exists_fn=_has_option('fastpreheat'),
|
||||
value_fn=lambda opts: _option_value(opts, 'fastpreheat') == 'On',
|
||||
write_fn=_fastpreheat_write),
|
||||
write_fn=_option_switch_write('fastpreheat')),
|
||||
SwitchDesc(key='natural_steam', field='x.com.samsung.da.options',
|
||||
icon='mdi:kettle-steam',
|
||||
exists_fn=_has_option('NaturalSteam'),
|
||||
value_fn=lambda opts: _option_value(opts, 'NaturalSteam') == 'On',
|
||||
write_fn=_naturalsteam_write),
|
||||
write_fn=_option_switch_write('NaturalSteam')),
|
||||
# 120-hour energy-saving standby (issue #183): confirmed present in
|
||||
# this unit's options[] (EnergySaving_On) and directly requested --
|
||||
# unlike fast_preheat/natural_steam above, this token is real on this
|
||||
# hardware, just previously unbound entirely.
|
||||
SwitchDesc(key='energy_saving', field='x.com.samsung.da.options',
|
||||
icon='mdi:leaf', entity_category='config',
|
||||
exists_fn=_has_option('EnergySaving'),
|
||||
value_fn=lambda opts: _option_value(opts, 'EnergySaving') == 'On',
|
||||
write_fn=_option_switch_write('EnergySaving')),
|
||||
# Cooktop-on alert (issue #183): also confirmed present
|
||||
# (BurnerOnAlert_Off) though the reporter noted it mainly matters for
|
||||
# the SmartThings app's own alerting, not local automation.
|
||||
SwitchDesc(key='cooktop_on_alert', field='x.com.samsung.da.options',
|
||||
icon='mdi:alert-circle-outline', entity_category='config',
|
||||
exists_fn=_has_option('BurnerOnAlert'),
|
||||
value_fn=lambda opts: _option_value(opts, 'BurnerOnAlert') == 'On',
|
||||
write_fn=_option_switch_write('BurnerOnAlert')),
|
||||
),
|
||||
)
|
||||
@@ -158,9 +158,6 @@
|
||||
}
|
||||
},
|
||||
"number": {
|
||||
"buzzer_volume": {
|
||||
"name": "Beep volume"
|
||||
},
|
||||
"cook_time": {
|
||||
"name": "Cook time"
|
||||
},
|
||||
@@ -214,6 +211,9 @@
|
||||
"100": "High"
|
||||
}
|
||||
},
|
||||
"cooler_temperature_setpoint": {
|
||||
"name": "Cooler temperature"
|
||||
},
|
||||
"day_brightness": {
|
||||
"name": "Cabinet brightness",
|
||||
"state": {
|
||||
@@ -1018,6 +1018,12 @@
|
||||
"natural_steam": {
|
||||
"name": "Natural steam"
|
||||
},
|
||||
"energy_saving": {
|
||||
"name": "Energy saving"
|
||||
},
|
||||
"cooktop_on_alert": {
|
||||
"name": "Cooktop-on alert"
|
||||
},
|
||||
"power_switch": {
|
||||
"name": "Power"
|
||||
},
|
||||
|
||||
@@ -158,9 +158,6 @@
|
||||
}
|
||||
},
|
||||
"number": {
|
||||
"buzzer_volume": {
|
||||
"name": "Zoemervolume"
|
||||
},
|
||||
"cook_time": {
|
||||
"name": "Bereidingstijd"
|
||||
},
|
||||
@@ -214,6 +211,9 @@
|
||||
"100": "Hoog"
|
||||
}
|
||||
},
|
||||
"cooler_temperature_setpoint": {
|
||||
"name": "Koeler temperatuur"
|
||||
},
|
||||
"day_brightness": {
|
||||
"name": "Helderheid kast",
|
||||
"state": {
|
||||
@@ -1018,6 +1018,12 @@
|
||||
"natural_steam": {
|
||||
"name": "Natuurlijke stoom"
|
||||
},
|
||||
"energy_saving": {
|
||||
"name": "Energiebesparing"
|
||||
},
|
||||
"cooktop_on_alert": {
|
||||
"name": "Waarschuwing kookplaat aan"
|
||||
},
|
||||
"power_switch": {
|
||||
"name": "Voeding"
|
||||
},
|
||||
|
||||
Reference in new issue
Block a user