Rename finish_time debounce -> hysteresis to match actual behavior

The gate holds finish_time at its last reported value until a new one
differs by at least a configured number of minutes, regardless of how
long that difference has been building up -- a magnitude-based deadband,
not a time-based debounce (which would wait for the value to stay put for
N minutes before accepting it). debounce invited the wrong mental model
for anyone reading the option name or the code later, so rename it
throughout before the option name ships: CONF_FINISH_TIME_DEBOUNCE_MINUTES
-> CONF_FINISH_TIME_HYSTERESIS_MINUTES, SensorDesc.debounce -> hysteresis,
LocalThingsSensor._debounce/_debounced_value -> _apply_hysteresis/
_hysteresis_value, and the options-flow data key/translations to match.
This commit is contained in:
Jelle Lauwers committed 2026-07-31 20:27:48 +02:00
1 parent d90562017f
commit 9ab3c5827c
8 files changed
+41 -39

No files matched your search

@@ -163,7 +163,7 @@ OPERATIONAL_STATE = Capability(
# firmware leaves a stale remainingTime after a cycle ends, and
# freezes it at '00:01:00' when progress reaches 'Finish'.
SensorDesc(key='finish_time', device_class='timestamp',
debounce=True, rep_fn=_finish_time),
hysteresis=True, rep_fn=_finish_time),
SensorDesc(key='completion_minutes',
icon='mdi:clock-outline', unit='min',
@@ -58,10 +58,10 @@ class SensorDesc(SamsungEntityDescription):
unit_fn: Optional[Callable[[dict], str]] = None # overrides `unit` from the live rep, when set
options: Optional[tuple] = None # required by HA when device_class == 'enum'
# Opt-in: gate this sensor's reported value behind the user-configurable
# CONF_FINISH_TIME_DEBOUNCE_MINUTES threshold (see sensor.py). Only for
# CONF_FINISH_TIME_HYSTERESIS_MINUTES threshold (see sensor.py). Only for
# values that are expected to jitter around their "true" value between
# device-side revisions -- not a general-purpose flag every sensor should set.
debounce: bool = False
hysteresis: bool = False
@dataclass(frozen=True, kw_only=True)