feat(airconditioner): filter alarm interval on legacy ARTIK051 boards
Adds the Select the official app offers next to the filter reminder -- 180/300/500/700 hours -- which this board generation keeps as a FilterAlarmTime_ token in /mode/vs/0's options[] rather than on a /filter/* resource. Confirmed on hardware: stepping through all four radio positions in the app moved that one token and nothing else across all 19 resources, so the token carries the hour count verbatim; and a local write of 500 to a unit sitting on 700 was accepted and kept, surviving a restart. The cloud exposes none of this, so it is only available locally. Gated with the counter it belongs to, so boards carrying a real /filter/airdustfilter/vs/0 threshold keep using that one -- the gate is covered by a test that injects the token into a newer board's dump, since no non-legacy fixture carries it and the assertion would otherwise pass for the wrong reason. Also settles what filter_time measures: it counts UP -- running time accumulated since the last filter reset, not time remaining -- which an earlier revision of that comment explicitly left open. Three independent things agree: the token rising while the unit runs, FilterAlarmTime_ being the threshold it is measured against, and /alarms/vs/0's filter entry tracking the counter across two units on one site (a live unsuffixed 'FilterAlarm'/'Created' at FilterTime_5595 against the 'FilterAlarm_OFF'/'Deleted' placeholder at 1915). The alarm clearing by itself the moment the counter dropped under the threshold is the causal half of that, not just correlation. Resetting the counter is NOT solved and no reset entity is added. The descriptor records what was tried, and what the failures do and do not prove, so the next attempt starts from evidence instead of from scratch. Short version: the reset is a *command* (custom.dustFilter/resetDustFilter), not a value write, which is why nothing that writes the counter works; I could not work out how to drive that command locally. /actions/vs/0 is the obvious local command channel but publishes no schema, and I did not enumerate guessed action names against a live appliance. Written with Claude (AI), on the author's own hardware; every result quoted above is measured on the device rather than inferred.
This commit is contained in:
1 parent
eb938205ab
commit
9ee0dbb8f9
7 files changed
+199
-8
No files matched your search
@@ -9,6 +9,7 @@
|
||||
"diagnosis_status",
|
||||
"display_light",
|
||||
"energy_kwh",
|
||||
"filter_alarm_time",
|
||||
"filter_time",
|
||||
"good_sleep",
|
||||
"humidity",
|
||||
|
||||
@@ -9,6 +9,7 @@
|
||||
"diagnosis_status",
|
||||
"display_light",
|
||||
"energy_kwh",
|
||||
"filter_alarm_time",
|
||||
"filter_time",
|
||||
"good_sleep",
|
||||
"humidity",
|
||||
|
||||
@@ -9,6 +9,7 @@
|
||||
"diagnosis_status",
|
||||
"display_light",
|
||||
"energy_kwh",
|
||||
"filter_alarm_time",
|
||||
"filter_time",
|
||||
"good_sleep",
|
||||
"humidity",
|
||||
|
||||
@@ -9,8 +9,8 @@ differs from all of them in three ways, each covered below:
|
||||
* No ``/mode/convenient/vs/0`` -- the convenient-mode preset is a ``Comode_*``
|
||||
token in ``/mode/vs/0``'s ``options`` array.
|
||||
* Several settings (SPI, auto clean, air monitoring, beep volume, Good Sleep,
|
||||
outdoor temperature, filter time) are ``options`` tokens too, where newer
|
||||
boards have dedicated resources.
|
||||
outdoor temperature, filter time and its alarm interval) are ``options``
|
||||
tokens too, where newer boards have dedicated resources.
|
||||
|
||||
Fan, swing, preset, SPI and beep-volume writes were all confirmed on hardware
|
||||
by read-back on the unit this fixture is dumped from. The issue #136 unit is
|
||||
@@ -103,8 +103,8 @@ def test_token_entities_present_with_calibrated_values():
|
||||
state = _state()
|
||||
# token/10 hours: 1715 displayed as "171 hours 0 minutes"... at 1710 in the
|
||||
# official app on this unit, which pins the scale (the .5 here is a later
|
||||
# reading). Whether it counts up or down is deliberately not asserted --
|
||||
# see the descriptor comment.
|
||||
# reading). It counts up -- see the descriptor comment and
|
||||
# test_filter_alarm_tracks_the_counter_against_its_threshold below.
|
||||
assert state['filter_time'] == 171.5
|
||||
# token - 55 == 19 C, against a 19.4 C forecast at the time of the dump.
|
||||
assert state['outdoor_temperature'] == 19.0
|
||||
@@ -180,6 +180,82 @@ def test_option_writes_carry_one_token():
|
||||
)
|
||||
|
||||
|
||||
# -- filter counter and its reset ---------------------------------------------
|
||||
|
||||
def _desc(resources, key):
|
||||
"""The bound descriptor for `key`, or None when its exists_fn declines it.
|
||||
|
||||
flatten() gives values, not descriptors, so this is how a test reaches a
|
||||
descriptor's own write_fn and options without standing up an HA entity.
|
||||
"""
|
||||
bound, _ = _discover(resources)
|
||||
for item in bound:
|
||||
if item.desc.key == key and (
|
||||
item.desc.exists_fn is None
|
||||
or item.desc.exists_fn(resources.get(item.href) or {}, resources)
|
||||
):
|
||||
return item.desc
|
||||
return None
|
||||
|
||||
|
||||
def test_filter_alarm_time_reads_the_threshold_and_writes_one_token():
|
||||
"""The interval FilterTime_ is measured against, offered by the app as a
|
||||
180/300/500/700 hour radio. All four were walked on hardware while watching
|
||||
all 19 resources: the token carries the hour count verbatim and each step
|
||||
moved that one field and nothing else, which is also what makes a static
|
||||
options tuple defensible here (the board advertises no supported-values
|
||||
list for options[] tokens)."""
|
||||
state = _state()
|
||||
assert state['filter_alarm_time'] == '500' # the fixture's own value
|
||||
|
||||
desc = _desc(_load_device(FIXTURE), 'filter_alarm_time')
|
||||
assert desc.options == ('180', '300', '500', '700')
|
||||
assert desc.write_fn('180', {}) == (
|
||||
['mode', 'vs', '0'],
|
||||
{'x.com.samsung.da.options': ['FilterAlarmTime_180']},
|
||||
)
|
||||
|
||||
|
||||
def test_filter_alarm_time_stays_off_boards_with_a_real_threshold_resource():
|
||||
"""Newer boards carry air_filter_threshold off supportedFilterDesiredUsage;
|
||||
two thresholds on one device would be a coin flip for the user.
|
||||
|
||||
No non-legacy fixture carries a FilterAlarmTime_ token today (only the two
|
||||
KRAC dumps have one at all), so asserting on an unmodified newer board
|
||||
would pass for the wrong reason -- absent token rather than the
|
||||
board-generation gate. The token is injected to exercise the gate itself,
|
||||
test_absent_token_yields_no_entity's technique in reverse."""
|
||||
newer = _load_device('airconditioner_tp1x_rac')
|
||||
assert _desc(newer, 'filter_alarm_time') is None
|
||||
|
||||
mode = newer['/mode/vs/0']
|
||||
mode['x.com.samsung.da.options'] = [
|
||||
*(mode.get('x.com.samsung.da.options') or []), 'FilterAlarmTime_500',
|
||||
]
|
||||
assert is_legacy_board(newer) is False
|
||||
assert _desc(newer, 'filter_alarm_time') is None
|
||||
|
||||
|
||||
def test_filter_alarm_tracks_the_counter_against_its_threshold():
|
||||
"""Why filter_time is read as elapsed rather than remaining: the same
|
||||
options blob carries the threshold, and /alarms/vs/0's filter entry is a
|
||||
'FilterAlarm_OFF'/'Deleted' placeholder below it. The sibling unit on the
|
||||
same site, at FilterTime_5595 against the same FilterAlarmTime_500, instead
|
||||
reported an unsuffixed 'FilterAlarm' in state 'Created'."""
|
||||
resources = _load_device(FIXTURE)
|
||||
options = resources['/mode/vs/0']['x.com.samsung.da.options']
|
||||
assert 'FilterTime_1715' in options
|
||||
assert 'FilterAlarmTime_500' in options
|
||||
|
||||
alarms = resources['/alarms/vs/0']['x.com.samsung.da.items']
|
||||
filter_alarm = next(
|
||||
item for item in alarms
|
||||
if item['x.com.samsung.da.code'].startswith('FilterAlarm')
|
||||
)
|
||||
assert filter_alarm['x.com.samsung.da.code'] == 'FilterAlarm_OFF'
|
||||
assert filter_alarm['x.com.samsung.da.state'] == 'Deleted'
|
||||
|
||||
|
||||
# -- climate entity: fan, swing and preset off /airflow/vs/0 ------------------
|
||||
|
||||
def test_fan_mode_reads_the_airflow_speed_level():
|
||||
|
||||
Reference in new issue