feat: add Samsung Air Monitor Plus support (#210)

New device family: a standalone, battery-powered air-quality sensor
puck (ASM-KR-TP1-22-* board) with no controllable-appliance state at
all -- no /power/*, only /energy/battery/vs/0. Routes via both /oic/d
('x.com.st.d.airqualitysensor', confirmed against the real dump) and
the 'ASM' modelNum board token as a fallback.

/sensors/vs/0 reuses air_purifier.AIR_QUALITY's existing {type, value}
items-list decode (common.sensor_item_value) for dust/fine_dust/
super_fine_dust/odor/clean_level, sharing those capabilities' catalog
entries, and adds a CO2 reading those families don't report. The
particulate sensors deliberately get no pm10/pm25/pm1 device_class:
the values read as physically consistent (coarser >= finer) but
Samsung's own two-tier dust naming doesn't confirm where this board's
three-tier split actually maps, and mislabeling a read-side unit is a
standing, not one-shot, kind of wrong -- exposed as plain named
sensors instead. Humidity, battery/charging, and the informational air
quality standard are otherwise straightforward field reads.

/dnd/vs/0 (do-not-disturb window) is a flagged educated guess: the
write contract mirrors the read side's own string/time-format shape
(the safest kind of guess) but has no idle-vs-active dump to confirm
it end-to-end, so it's called out as such in code and will need a
reporter to verify on real hardware. /keepnormalstate/vs/0 and
/sensordatasinks/vs/0 are genuinely opaque (single unexplained value,
no supported-values list) and are ignored rather than guessed at.

Locked in with a scrubbed fixture, golden, and capability tests.
This commit is contained in:
Marc Billow committed 2026-07-31 02:40:02 +00:00
1 parent 4afd11a357
commit a7d57086e9
10 files changed
+588 -4

No files matched your search

+184
View File
@@ -0,0 +1,184 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/airqualitystandard/vs/0",
"rep": {
"x.com.samsung.da.standard": "AirCleanAssociation"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-30T02:42:57",
"x.com.samsung.da.state": "Deleted"
}
],
"rt": [
"x.com.samsung.da.alarms"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/dnd/vs/0",
"rep": {
"x.com.samsung.da.value": "false",
"x.com.samsung.da.startTime": "14:00:00",
"x.com.samsung.da.endTime": "22:00:00",
"x.com.samsung.da.visible": "true"
}
},
{
"href": "/energy/battery/vs/0",
"rep": {
"x.com.samsung.da.battery": "80",
"x.com.samsung.da.batteryResolution": "1",
"x.com.samsung.da.charging": "Off"
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "57",
"x.com.samsung.da.validity": "Valid"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "ASM-KR-TP1-22-ACMB1M|10243041|75000000001611C40800020000080000",
"x.com.samsung.da.description": "ASM-KR-TP1-22-ACMB1M",
"x.com.samsung.da.serialNum": "REDACTED",
"x.com.samsung.da.otnDUID": "REDACTED",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02443A260310",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "22050300",
"x.com.samsung.da.newVersionAvailable": "0"
}
],
"x.com.samsung.da.diagProtocolType": "WIFI_HTTPS",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AM0",
"x.com.samsung.da.diagMinVersion": "1.0"
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 0
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "true",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/sensordatasinks/vs/0",
"rep": {
"remove": ""
}
},
{
"href": "/sensors/vs/0",
"rep": {
"x.com.samsung.da.cleanLevel": "2",
"x.com.samsung.da.refresh": "Off",
"x.com.samsung.da.lastSensingTime": "1785379376",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Sensor for CleanLevel",
"x.com.samsung.da.type": "CleanLevel",
"x.com.samsung.da.value": [
"2"
]
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Sensor for Odor",
"x.com.samsung.da.type": "Odor",
"x.com.samsung.da.value": [
"1"
]
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Sensor for Dust",
"x.com.samsung.da.type": "Dust",
"x.com.samsung.da.value": [
"31",
"2"
]
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Sensor for FineDust",
"x.com.samsung.da.type": "FineDust",
"x.com.samsung.da.value": [
"23",
"2"
]
},
{
"x.com.samsung.da.id": "4",
"x.com.samsung.da.description": "Sensor for SuperFineDust",
"x.com.samsung.da.type": "SuperFineDust",
"x.com.samsung.da.value": [
"18",
"2"
]
},
{
"x.com.samsung.da.id": "5",
"x.com.samsung.da.description": "Sensor for CO2",
"x.com.samsung.da.type": "CO2",
"x.com.samsung.da.value": [
"498",
"1"
]
}
]
}
}
]
}
+18
View File
@@ -0,0 +1,18 @@
{
"state_keys": [
"air_quality_standard",
"alarm_code",
"battery",
"battery_charging",
"clean_level",
"co2",
"dnd",
"dnd_end",
"dnd_start",
"dust",
"fine_dust",
"humidity",
"odor",
"super_fine_dust"
]
}
+115
View File
@@ -0,0 +1,115 @@
"""Tests for the Samsung Air Monitor Plus family (ASM-KR-TP1-22-ACMB1M,
issue #210) -- a standalone, battery-powered air-quality sensor puck. No
controllable appliance state at all beyond the do-not-disturb window.
"""
from datetime import time as dt_time
from custom_components.localthings.registry.adapter import flatten
from custom_components.localthings.registry.by_type import for_device_by_oic_type, resolve
from custom_components.localthings.registry.discovery import discover
from tests.conftest import _load_device
def _air_monitor():
resources = _load_device('air_monitor')
reg = resolve(resources)
return reg, resources
def _bound():
reg, resources = _air_monitor()
return discover(resources, reg.capabilities, reg.pattern_capabilities), resources
def _state():
bound, resources = _bound()
return flatten(bound, resources)
def _desc(key):
bound, _ = _bound()
return next(b.desc for b in bound if b.desc.key == key)
def test_resolves_to_air_monitor_registry():
reg, _ = _air_monitor()
assert reg is not None and reg.name == 'air_monitor'
def test_resolves_via_oic_type_too():
"""This board's real dump carries /oic/d's device type
('x.com.st.d.airqualitysensor') as well as the 'ASM' modelNum token --
both paths must agree."""
reg = for_device_by_oic_type(('x.com.st.d.airqualitysensor',))
assert reg is not None and reg.name == 'air_monitor'
def test_no_unbound_hrefs():
reg, resources = _air_monitor()
unbound = []
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
assert unbound == []
def test_air_quality_sensors_read_from_shared_items_decode():
"""Same /sensors/vs/0 {type, value} shape and common.sensor_item_value
decode air_purifier.AIR_QUALITY already uses -- this board adds CO2,
which neither air_purifier nor range_hood report."""
state = _state()
assert state['dust'] == 31
assert state['fine_dust'] == 23
assert state['super_fine_dust'] == 18
assert state['odor'] == 1
assert state['clean_level'] == 2
assert state['co2'] == 498
def test_second_value_slot_is_not_exposed():
"""Dust/fine_dust/super_fine_dust each carry a second `value[1]` grade
code (e.g. Dust's ['31', '2']) with no supported-values field anywhere
in the dump to explain its scale -- per the 'still never invent... from
nothing' rule, only the raw reading (value[0]) is bound, not a second
'dust_level' or similar entity for that code."""
state = _state()
assert 'dust_level' not in state
assert 'dust_grade' not in state
def test_humidity_and_battery_present():
state = _state()
assert state['humidity'] == 57
assert state['battery'] == 80
assert state['battery_charging'] is False
def test_air_quality_standard_present():
state = _state()
assert state['air_quality_standard'] == 'AirCleanAssociation'
def test_dnd_read_contract():
state = _state()
assert state['dnd'] is False
assert state['dnd_start'] == dt_time(14, 0)
assert state['dnd_end'] == dt_time(22, 0)
def test_dnd_write_contracts_are_flagged_educated_guesses():
"""Issue #210: no idle-vs-active dump pair exists for /dnd/vs/0 (DND
was never toggled in the one dump this board has), so these write
contracts are educated guesses -- symmetric with the read side's own
string/time-format shape, not invented from nothing, but still
unconfirmed on real hardware. Only the wiring is tested here; whether
the device actually accepts these writes needs a reporter to confirm."""
dnd = _desc('dnd')
path, body = dnd.write_fn('On', {})
assert path == ['dnd', 'vs', '0']
assert body == {'x.com.samsung.da.value': 'true'}
path, body = dnd.write_fn('Off', {})
assert body == {'x.com.samsung.da.value': 'false'}
start = _desc('dnd_start')
path, body = start.write_fn(dt_time(9, 30), {})
assert path == ['dnd', 'vs', '0']
assert body == {'x.com.samsung.da.startTime': '09:30:00'}
+14
View File
@@ -151,6 +151,7 @@ class TestForDeviceByOicType:
('oic.d.washer', 'washer'),
('x.com.st.d.stickcleaner', 'vacuum_station'),
('x.com.st.d.steamcloset', 'air_dresser'),
('x.com.st.d.airqualitysensor', 'air_monitor'),
])
def test_known_oic_types_resolve(self, oic_type, expected):
from custom_components.localthings.registry.by_type import for_device_by_oic_type
@@ -434,6 +435,19 @@ class TestForDeviceByModel:
assert reg is not None
assert reg.name == 'vacuum_station'
def test_air_monitor_via_asm_token(self):
"""Issue #210: a standalone air-quality sensor puck
(ASM-KR-TP1-22-ACMB1M) reports no oneUiVersion and no
washer/dryer/dishwasher consumer prefix; falls back to the 'ASM'
token in modelNum onto the air_monitor registry."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'ASM-KR-TP1-22-ACMB1M|10243041|75000000001611C40800020000080000',
'ASM-KR-TP1-22-ACMB1M',
)
assert reg is not None
assert reg.name == 'air_monitor'
def test_cooktop_via_legacy_model_description(self):
"""Older cooktops identify themselves as ARTIK051_GLOBAL_COOKTOP."""
from custom_components.localthings.registry.by_type import for_device_by_model
+21
View File
@@ -871,6 +871,27 @@ def test_registry_reproduces_golden_state_keys_for_air_dresser_tp1_21():
)
def test_registry_reproduces_golden_state_keys_for_air_monitor():
"""Samsung Air Monitor Plus (ASM-KR-TP1-22-ACMB1M, issue #210) -- a
standalone battery-powered air-quality sensor puck, the first device
this integration has no controllable-appliance concept for at all (no
/power/*, only /energy/battery/vs/0). Routes via both /oic/d
('x.com.st.d.airqualitysensor') and the 'ASM' modelNum board token.
Reuses air_purifier.AIR_QUALITY's /sensors/vs/0 decode
(common.sensor_item_value) for dust/fine_dust/super_fine_dust/odor/
clean_level, adding a CO2 reading those families don't report. Binds
cleanly with zero unbound hrefs."""
from tests.conftest import _load_device
resources = _load_device('air_monitor')
golden = json.loads((GOLDEN / 'air_monitor.json').read_text())
state_keys = _new_state_keys('air_monitor', resources)
assert set(state_keys) == set(golden['state_keys']), (
f"state_keys mismatch:\n"
f" extra: {sorted(set(state_keys) - set(golden['state_keys']))}\n"
f" missing: {sorted(set(golden['state_keys']) - set(state_keys))}"
)
def test_registry_reproduces_golden_state_keys_for_air_purifier_vtww():
"""A-VTWW-TP2-21-COMMON BESPOKE Cube Air (issue #151) -- reports no
oneUiVersion; resolved via the '-VTWW-' modelNum token fallback into