Extract usable parts of PR #316 (System Fresh Air Ventilator support)

PR #316 (fork stale by several months, most of its ~2200-line diff was drift
against main rather than real changes) proposed device support for the
Samsung System Fresh Air Ventilator (ACA-KR-TP2-21-AN9000). Extracted what
holds up, adapted to this project's conventions, and left out what doesn't:

Extracted:
- ventilation_mode select on CLIMATE's own href, gated via
  _is_ventilation_mode_device so it can only ever bind on a device whose
  entire supportedModes set is Purification/Ventilation/SmartVentilation --
  verified against every real AC fixture in the corpus to confirm it can't
  false-positive on an actual air conditioner's climate card.
- WINDFREE / WINDSLEEP switches on their own dedicated hrefs.
- A CO2 sensor on AIR_QUALITY, matching air_monitor.SENSORS' already-bound
  device_class='carbon_dioxide'/unit='ppm' descriptor for the same field
  shape rather than guessing fresh.
- HEPA_FILTER / DEVICE_ACTIVE reuse from air_purifier.py.
- Removing /airlevelcheck/vs/0 from _AC_IGNORED and binding
  air_purifier.AIR_LEVEL_CHECK in its place: the PR's claim that this
  project's old "scheduler plumbing" description was wrong turned out to
  be independently verifiable against two of our own existing fixtures
  (airconditioner_cac and airconditioner_tp1x_da_ac_rac_01011 both already
  carry real, populated periodicSensingActivationState/autoExeState
  values), so this benefits existing users, not just the one new device.

Left out:
- Unit/device_class ('ug/m3', pm10/pm25/pm1) on the existing dust/
  fine_dust/super_fine_dust sensors, sourced from an unverified third-party
  screenshot description. air_monitor.py already has an explicit, reasoned
  rejection of this exact mapping for the exact same three fields:
  Samsung's PM10/PM2.5 convention doesn't confirm where a third tier or a
  PM1 reading fits, and a wrong guess mislabels the reading forever.
- A standalone common.POWER switch -- contradicts this registry's own
  documented design (power is deliberately the climate entity's job) and
  would affect every AC user, not just this device.
- Promoting wind/swing to independent selects for every AC user -- a UX
  opinion, not a coverage necessity, and out of scope for this device's
  own support.
- A model-name diagnostic sensor -- /information/vs/0 is already covered
  via the global ignore list, so this wasn't closing an actual gap.

No raw diagnostics dump for this model was ever attached to PR #316, so
there's no fixture for it here (fabricating one would violate this
project's fixture-integrity rule) -- see
tests/test_airconditioner_ventilation_windfree.py's module docstring.
This commit is contained in:
Marc Billow committed 2026-08-07 16:38:09 +00:00
1 parent 8551974719
commit a7dc1db8ff
13 files changed
+361 -1

No files matched your search

+22
View File
@@ -33,6 +33,13 @@ until issue #270 (TP1X_FAC_TIME_23K) added real capabilities for both --
this board's own live filterUsage/filterStatus data on the PM1 filter binds
through the same exists_fn-gated entities #270's dump (which has neither
field) leaves empty.
/airlevelcheck/vs/0 was never on this unbound list (this fixture's rep
already carried a full set of periodicSensing*/autoExeState fields), but
until PR #316 it was globally ignored by airconditioner.py's own
_AC_IGNORED as "scheduler plumbing" -- this fixture's own populated values
were the proof that description was wrong. air_purifier.AIR_LEVEL_CHECK
now covers it (see test_airlevelcheck_binds_real_ai_purify_state below).
"""
from custom_components.localthings.registry.adapter import flatten
@@ -85,6 +92,21 @@ def test_mds_absenceclean_shares_csi_absenceclean_key():
assert state["absence_clean"] is False
def test_airlevelcheck_binds_real_ai_purify_state():
"""This fixture's /airlevelcheck/vs/0 has real, populated values --
periodic_air_sensing on, sensing_mode 'Alarm' -- confirming
air_purifier.AIR_LEVEL_CHECK binds real AI-Purify state here rather
than the inert plumbing _AC_IGNORED used to describe."""
resources = _resources()
reg = _reg(resources)
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
state = flatten(bound, resources)
assert state["periodic_air_sensing"] is True
assert state["sensing_mode"] == "Alarm"
assert state["sensing_interval"] == 30 # 1800s
assert state["air_sensing_state"] == "NonProcessing"
def test_non_legacy_board_uses_the_generic_energy_scale():
"""This board reports /wind/strength/vs/0 (not /airflow/vs/0), so