Extract usable parts of PR #316 (System Fresh Air Ventilator support)
PR #316 (fork stale by several months, most of its ~2200-line diff was drift against main rather than real changes) proposed device support for the Samsung System Fresh Air Ventilator (ACA-KR-TP2-21-AN9000). Extracted what holds up, adapted to this project's conventions, and left out what doesn't: Extracted: - ventilation_mode select on CLIMATE's own href, gated via _is_ventilation_mode_device so it can only ever bind on a device whose entire supportedModes set is Purification/Ventilation/SmartVentilation -- verified against every real AC fixture in the corpus to confirm it can't false-positive on an actual air conditioner's climate card. - WINDFREE / WINDSLEEP switches on their own dedicated hrefs. - A CO2 sensor on AIR_QUALITY, matching air_monitor.SENSORS' already-bound device_class='carbon_dioxide'/unit='ppm' descriptor for the same field shape rather than guessing fresh. - HEPA_FILTER / DEVICE_ACTIVE reuse from air_purifier.py. - Removing /airlevelcheck/vs/0 from _AC_IGNORED and binding air_purifier.AIR_LEVEL_CHECK in its place: the PR's claim that this project's old "scheduler plumbing" description was wrong turned out to be independently verifiable against two of our own existing fixtures (airconditioner_cac and airconditioner_tp1x_da_ac_rac_01011 both already carry real, populated periodicSensingActivationState/autoExeState values), so this benefits existing users, not just the one new device. Left out: - Unit/device_class ('ug/m3', pm10/pm25/pm1) on the existing dust/ fine_dust/super_fine_dust sensors, sourced from an unverified third-party screenshot description. air_monitor.py already has an explicit, reasoned rejection of this exact mapping for the exact same three fields: Samsung's PM10/PM2.5 convention doesn't confirm where a third tier or a PM1 reading fits, and a wrong guess mislabels the reading forever. - A standalone common.POWER switch -- contradicts this registry's own documented design (power is deliberately the climate entity's job) and would affect every AC user, not just this device. - Promoting wind/swing to independent selects for every AC user -- a UX opinion, not a coverage necessity, and out of scope for this device's own support. - A model-name diagnostic sensor -- /information/vs/0 is already covered via the global ignore list, so this wasn't closing an actual gap. No raw diagnostics dump for this model was ever attached to PR #316, so there's no fixture for it here (fabricating one would violate this project's fixture-integrity rule) -- see tests/test_airconditioner_ventilation_windfree.py's module docstring.
This commit is contained in:
13 files changed
+361
-1
No files matched your search
@@ -33,6 +33,13 @@ until issue #270 (TP1X_FAC_TIME_23K) added real capabilities for both --
|
||||
this board's own live filterUsage/filterStatus data on the PM1 filter binds
|
||||
through the same exists_fn-gated entities #270's dump (which has neither
|
||||
field) leaves empty.
|
||||
|
||||
/airlevelcheck/vs/0 was never on this unbound list (this fixture's rep
|
||||
already carried a full set of periodicSensing*/autoExeState fields), but
|
||||
until PR #316 it was globally ignored by airconditioner.py's own
|
||||
_AC_IGNORED as "scheduler plumbing" -- this fixture's own populated values
|
||||
were the proof that description was wrong. air_purifier.AIR_LEVEL_CHECK
|
||||
now covers it (see test_airlevelcheck_binds_real_ai_purify_state below).
|
||||
"""
|
||||
|
||||
from custom_components.localthings.registry.adapter import flatten
|
||||
@@ -85,6 +92,21 @@ def test_mds_absenceclean_shares_csi_absenceclean_key():
|
||||
assert state["absence_clean"] is False
|
||||
|
||||
|
||||
def test_airlevelcheck_binds_real_ai_purify_state():
|
||||
"""This fixture's /airlevelcheck/vs/0 has real, populated values --
|
||||
periodic_air_sensing on, sensing_mode 'Alarm' -- confirming
|
||||
air_purifier.AIR_LEVEL_CHECK binds real AI-Purify state here rather
|
||||
than the inert plumbing _AC_IGNORED used to describe."""
|
||||
resources = _resources()
|
||||
reg = _reg(resources)
|
||||
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
|
||||
state = flatten(bound, resources)
|
||||
assert state["periodic_air_sensing"] is True
|
||||
assert state["sensing_mode"] == "Alarm"
|
||||
assert state["sensing_interval"] == 30 # 1800s
|
||||
assert state["air_sensing_state"] == "NonProcessing"
|
||||
|
||||
|
||||
def test_non_legacy_board_uses_the_generic_energy_scale():
|
||||
"""This board reports /wind/strength/vs/0 (not /airflow/vs/0), so
|
||||
is_legacy_board() is False and it must use the plain wh_to_kwh scale,
|
||||
|
||||
Reference in new issue
Block a user