Read AC fan speeds from the device's own modesName, not just 0-4 (#155)

TP1X_DA-AC-RAC-01001_0000 (model AR07C9150HZN) reports /wind/strength/vs/0
supportedModes as "0"/"31"-"35" instead of the "0"-"4" scale climate.py's
_DEVICE_TO_FAN was built from. Only "0" matched, so fan_mode/fan_modes
silently dropped every speed but Auto -- exactly the reported symptom.

Rather than hardcoding a second numeric scale, codes _DEVICE_TO_FAN doesn't
cover now fall back to the device's own modesName label (parallel-indexed
with supportedModes), mirroring how preset_mode already resolves dynamically
off a device's own supportedModes instead of a per-model table. Boards using
the standard 0-4 scale are unaffected -- _DEVICE_TO_FAN is still tried
first, so existing auto/low/medium/high/turbo labels don't change.
This commit is contained in:
Marc Billow committed 2026-07-28 13:38:42 +00:00
1 parent 57e06c5ccb
commit aa9cdd83b7
7 files changed
+712 -5

No files matched your search

@@ -0,0 +1,17 @@
{
"state_keys": [
"air_filter_status",
"air_filter_usage",
"alarm_code",
"auto_clean",
"climate",
"current_temperature_c",
"display_light",
"energy_kwh",
"energy_saved_kwh",
"firmware_update",
"humidity",
"mute_once",
"power_watts"
]
}