@@ -12,6 +12,7 @@ from typing import Any
|
||||
|
||||
import voluptuous as vol
|
||||
from homeassistant import config_entries
|
||||
from homeassistant.core import callback
|
||||
from homeassistant.data_entry_flow import FlowResult
|
||||
from homeassistant.helpers.selector import (
|
||||
TextSelector,
|
||||
@@ -24,6 +25,7 @@ from .const import (
|
||||
CONF_HOST, CONF_PORT,
|
||||
CONF_CA_CERT_PEM, CONF_CA_KEY_PEM,
|
||||
CONF_LEAF_CERT_PEM, CONF_LEAF_KEY_PEM,
|
||||
CONF_BYPASS_REMOTE_CONTROL,
|
||||
PROBE_PORT_RANGE, PREFERRED_PROBE_PORTS, LIVENESS_PROBE_TIMEOUT_S,
|
||||
PROBE_GET_TIMEOUT_S,
|
||||
)
|
||||
@@ -300,6 +302,13 @@ class LocalThingsConfigFlow(config_entries.ConfigFlow, domain=DOMAIN):
|
||||
self._ca_key_pem: str = ""
|
||||
self._pending_info: dict | None = None
|
||||
|
||||
@staticmethod
|
||||
@callback
|
||||
def async_get_options_flow(
|
||||
config_entry: config_entries.ConfigEntry,
|
||||
) -> LocalThingsOptionsFlow:
|
||||
return LocalThingsOptionsFlow()
|
||||
|
||||
def _create_entry(self, info: dict) -> FlowResult:
|
||||
return self.async_create_entry(
|
||||
title=f"Samsung Appliance ({self._host})",
|
||||
@@ -384,3 +393,31 @@ class LocalThingsConfigFlow(config_entries.ConfigFlow, domain=DOMAIN):
|
||||
"one_ui_version": self._pending_info["one_ui_version"] or "(none reported)",
|
||||
},
|
||||
)
|
||||
|
||||
|
||||
class LocalThingsOptionsFlow(config_entries.OptionsFlow):
|
||||
"""Per-device override of the remote-control-off write block (issue
|
||||
#54). The block exists because most devices reject writes outright
|
||||
while remote control is off and a clear error beats a silent
|
||||
device-side rejection -- but not every model actually enforces that,
|
||||
so this lets a user who's confirmed their device accepts writes anyway
|
||||
turn the block off for just that device rather than it being
|
||||
hardcoded on for everyone."""
|
||||
|
||||
async def async_step_init(
|
||||
self, user_input: dict[str, Any] | None = None
|
||||
) -> FlowResult:
|
||||
if user_input is not None:
|
||||
return self.async_create_entry(data=user_input)
|
||||
|
||||
return self.async_show_form(
|
||||
step_id="init",
|
||||
data_schema=vol.Schema({
|
||||
vol.Required(
|
||||
CONF_BYPASS_REMOTE_CONTROL,
|
||||
default=self.config_entry.options.get(
|
||||
CONF_BYPASS_REMOTE_CONTROL, False
|
||||
),
|
||||
): bool,
|
||||
}),
|
||||
)
|
||||
@@ -12,6 +12,16 @@ CONF_CA_KEY_PEM = "ca_key_pem"
|
||||
CONF_LEAF_CERT_PEM = "leaf_cert_pem"
|
||||
CONF_LEAF_KEY_PEM = "leaf_key_pem"
|
||||
|
||||
# Options-flow key (entry.options, not entry.data): lets a user override the
|
||||
# device-wide remote-control-off write block for a specific device (issue
|
||||
# #54). Some devices report remote control off yet still accept certain
|
||||
# writes (e.g. default detergent/softener dosing on a washer, applied even
|
||||
# to the built-in programs) -- the block exists to give a clear error
|
||||
# instead of a silent device-side rejection, but that assumption doesn't
|
||||
# hold for every model. Defaults to False (block stays on) everywhere it's
|
||||
# read, so devices this doesn't apply to see no behavior change.
|
||||
CONF_BYPASS_REMOTE_CONTROL = "bypass_remote_control_lock"
|
||||
|
||||
# The DTLS/CoAP local API binds somewhere in this ephemeral range; which port
|
||||
# depends on firmware. Newer builds answer on 49154/49155, but older ones have
|
||||
# been seen as low as 49153, so we sweep the whole range for a live UDP port
|
||||
|
||||
@@ -31,7 +31,7 @@ from .observe import ObserveManager, MODE_OBSERVE, MODE_POLL, GRACE_PERIOD_S
|
||||
|
||||
from .const import (
|
||||
DOMAIN, CONF_HOST, CONF_PORT, CONF_LEAF_CERT_PEM, CONF_LEAF_KEY_PEM,
|
||||
DEVICE_SUPPORT_ISSUE_URL, SUMMARY_INTERVAL_S,
|
||||
CONF_BYPASS_REMOTE_CONTROL, DEVICE_SUPPORT_ISSUE_URL, SUMMARY_INTERVAL_S,
|
||||
)
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
@@ -77,6 +77,14 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
|
||||
# fine session shouldn't tear down a working OBSERVE subscription.
|
||||
_POLL_TIMEOUT_LIMIT: int = 3
|
||||
|
||||
# Timeouts for the two network round trips a write triggers: the PUT
|
||||
# itself (_do_put), then the confirming full /device/0 summary poll
|
||||
# async_send_command requests right after (_poll_once). Named here
|
||||
# (rather than left as inline literals) so the write-settle window
|
||||
# below can be sized to always outlast both — see async_send_command.
|
||||
_POST_TIMEOUT_S: float = 8.0
|
||||
_POLL_TIMEOUT_S: float = 35.0
|
||||
|
||||
def __init__(self, hass: HomeAssistant, entry: ConfigEntry) -> None:
|
||||
# Per-device logger (module logger scoped to this device's host) so
|
||||
# every log line — including the base DataUpdateCoordinator's own
|
||||
@@ -211,7 +219,7 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
|
||||
# would have succeeded, not a dead session. 35s gives a slow
|
||||
# blockwise transfer room to actually finish instead of
|
||||
# generating a TimeoutError every cycle.
|
||||
code, payload = sess.get(_SEED_PATH, timeout=35.0)
|
||||
code, payload = sess.get(_SEED_PATH, timeout=self._POLL_TIMEOUT_S)
|
||||
except TimeoutError:
|
||||
raise
|
||||
except Exception as e:
|
||||
@@ -526,7 +534,11 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
|
||||
user-facing message -- as opposed to write_fn's silent no-op below
|
||||
-- is available to every platform for free. The remote-control
|
||||
check runs first and applies to every platform unconditionally,
|
||||
ahead of any description-specific validate_fn."""
|
||||
ahead of any description-specific validate_fn -- unless the user has
|
||||
opted this device out of it via CONF_BYPASS_REMOTE_CONTROL (issue
|
||||
#54: some devices accept certain writes, e.g. a washer's default
|
||||
dosing levels, even while reporting remote control off, so the
|
||||
block's assumption doesn't hold for every model)."""
|
||||
desc = bound_entity.desc
|
||||
write_fn = getattr(desc, 'write_fn', None)
|
||||
if write_fn is None:
|
||||
@@ -534,7 +546,8 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
|
||||
href = bound_entity.href
|
||||
rep = self._cache.get(href or '') or {}
|
||||
resources = self._cache.snapshot()
|
||||
if not remote_control_enabled(resources):
|
||||
bypass_remote_control = self._entry.options.get(CONF_BYPASS_REMOTE_CONTROL, False)
|
||||
if not bypass_remote_control and not remote_control_enabled(resources):
|
||||
raise ServiceValidationError(_REMOTE_CONTROL_DISABLED_MESSAGE)
|
||||
validate_fn = getattr(desc, 'validate_fn', None)
|
||||
if validate_fn is not None:
|
||||
@@ -571,14 +584,44 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
|
||||
# onto, the settle window was just delaying the real device
|
||||
# confirmation for a few seconds on every write, which read exactly
|
||||
# like the write being silently reverted (issue #27).
|
||||
#
|
||||
# settle_s must outlast the PUT and the async_request_refresh()
|
||||
# below combined, not just DEFAULT_SETTLE_S's fixed few seconds --
|
||||
# that refresh is a full /device/0 summary poll, which
|
||||
# _POLL_TIMEOUT_S itself admits can legitimately take tens of
|
||||
# seconds on these devices (see _poll_once), and some writes settle
|
||||
# on the device itself well after that: issue #9's washer packs
|
||||
# cycle/detergent/softener selection into the same /course/vs/0
|
||||
# options[] array, and picking a new value there visibly needs a
|
||||
# few seconds of internal validation/dispenser movement before the
|
||||
# device's own state agrees -- while /washer/vs/0's temperature/
|
||||
# spin fields (plain flags, no device-side settling) confirm
|
||||
# instantly on the same device. A short fixed window expired while
|
||||
# the confirm poll was still in flight (or before the device had
|
||||
# caught up internally), so that stale read landed unprotected and
|
||||
# reverted the optimistic value, self-correcting again only once a
|
||||
# later poll finally saw the real change -- read by the user as the
|
||||
# write "reverting, then re-applying itself" a few seconds later.
|
||||
#
|
||||
# An earlier attempt at this also released the guard early, right
|
||||
# after the confirming refresh completed, to avoid shutting out
|
||||
# unrelated real updates (another automation, the physical remote)
|
||||
# for the rest of settle_s. That was reverted: releasing the guard
|
||||
# the moment one round trip finishes doesn't mean the device has
|
||||
# actually caught up (exactly the slow-settling case above), and it
|
||||
# introduced its own races around overlapping writes to the same
|
||||
# href. Simpler and safer to just hold the guard for the full,
|
||||
# generously-sized window and let it expire on its own.
|
||||
self._observe.apply(write_href, body, source='optimistic')
|
||||
self._observe.mark_write_pending(write_href)
|
||||
self._observe.mark_write_pending(
|
||||
write_href, settle_s=self._POST_TIMEOUT_S + self._POLL_TIMEOUT_S
|
||||
)
|
||||
|
||||
def _do_put():
|
||||
sess = self._session
|
||||
if sess is None:
|
||||
raise RuntimeError("no session")
|
||||
code, _ = sess.post(path_segs, cbor2.dumps(body), timeout=8.0)
|
||||
code, _ = sess.post(path_segs, cbor2.dumps(body), timeout=self._POST_TIMEOUT_S)
|
||||
self._log.info("PUT %s → code %#04x", write_href, code)
|
||||
|
||||
try:
|
||||
|
||||
@@ -12,5 +12,5 @@
|
||||
"pyOpenSSL>=23.0",
|
||||
"smartthings-local>=0.1.0"
|
||||
],
|
||||
"version": "0.10.1"
|
||||
"version": "0.11.1"
|
||||
}
|
||||
@@ -115,8 +115,22 @@ class ObserveManager:
|
||||
could each read the same prior rep and the second writer would
|
||||
silently lose the first's fields, reintroducing the exact bug
|
||||
this merge fixes.
|
||||
|
||||
`source == 'optimistic'` always bypasses the settle gate below,
|
||||
even while this href is already settling from an earlier write.
|
||||
Several independent selects can share one href -- issue #9's washer
|
||||
packs cycle, detergent, and softener settings onto the same
|
||||
/course/vs/0 -- so a second, different write to the same href
|
||||
while the first's settle window is still open (up to
|
||||
_POST_TIMEOUT_S + _POLL_TIMEOUT_S, tens of seconds -- see
|
||||
coordinator.async_send_command) is an expected, normal sequence,
|
||||
not a stale echo of the first write. Gating it the same as a
|
||||
poll/sweep/observe update would silently drop the user's own
|
||||
second selection from the cache until the first write's guard
|
||||
happened to expire, i.e. the exact symptom this guard exists to
|
||||
prevent, just relocated to whichever write loses the race.
|
||||
"""
|
||||
if self._is_settling(href):
|
||||
if source != 'optimistic' and self._is_settling(href):
|
||||
self.log.debug("dropping %s update for %s (settling)", source, href)
|
||||
return False
|
||||
with self._cache_lock:
|
||||
|
||||
@@ -113,6 +113,15 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
# 'P' sits between the underscore and 'RAC' in that token).
|
||||
if key is None and '_RAC_' in (model_num or ''):
|
||||
key = 'airconditioner'
|
||||
# System air conditioners (multi-indoor-unit commercial installs, e.g.
|
||||
# A-CAWW-TP2-20-COMMON, issue #52) report no oneUiVersion either and
|
||||
# carry the '-CAWW-' board-family token instead of '_RAC_'/'_PRAC_'.
|
||||
# Same TP1X/TP2X-class resource surface as the room-AC models above
|
||||
# (confirmed by the issue #52 dump binding cleanly against the existing
|
||||
# airconditioner registry once routed here), plus one new SAC-specific
|
||||
# resource (see airconditioner.py's _AC_IGNORED).
|
||||
if key is None and '-CAWW-' in (model_num or '').upper():
|
||||
key = 'airconditioner'
|
||||
# Air purifiers (e.g. ARTIK051_TVTL_18K, issue #56) report no
|
||||
# oneUiVersion either, and carry the '_TVTL_' board-family token.
|
||||
if key is None and '_TVTL_' in (model_num or ''):
|
||||
|
||||
@@ -243,6 +243,11 @@ _AC_IGNORED = [
|
||||
'/remotetemperature/vs/0', # external temp-sensor feed (unset on this unit)
|
||||
'/reserverulesets/vs/0', # opaque hex-encoded schedule reservation blob
|
||||
'/welcome/temperature/vs/0', # welcome-cooling plumbing
|
||||
# System-AC-only (multi-indoor-unit commercial installs, e.g.
|
||||
# A-CAWW-TP2-20-COMMON, issue #52): opaque hex-encoded installation
|
||||
# topology -- indoor/outdoor unit pairing, per-unit serials, MCU info.
|
||||
# Commissioning-time plumbing, not user-actionable appliance state.
|
||||
'/sac/installationinfo/vs/0',
|
||||
]
|
||||
|
||||
# Built as bare no-entity caps; folded into the AC registry (not global).
|
||||
|
||||
@@ -248,6 +248,17 @@
|
||||
"already_configured": "This device is already configured."
|
||||
}
|
||||
},
|
||||
"options": {
|
||||
"step": {
|
||||
"init": {
|
||||
"title": "Local Things Options",
|
||||
"description": "Some devices accept certain writes (e.g. default detergent/softener dosing on a washer) even while reporting remote control off. By default, LocalThings blocks every write with a clear error whenever a device reports remote control off, rather than letting the device silently reject it. Only enable this if you've confirmed writes actually work on this device with remote control off -- otherwise you'll trade that clear error for a silent failure.",
|
||||
"data": {
|
||||
"bypass_remote_control_lock": "Allow writes even when remote control is reported off"
|
||||
}
|
||||
}
|
||||
}
|
||||
},
|
||||
"issues": {
|
||||
"device_gap": {
|
||||
"title": "Incomplete capability coverage for {device_name}",
|
||||
|
||||
@@ -248,6 +248,17 @@
|
||||
"already_configured": "This device is already configured."
|
||||
}
|
||||
},
|
||||
"options": {
|
||||
"step": {
|
||||
"init": {
|
||||
"title": "Local Things Options",
|
||||
"description": "Some devices accept certain writes (e.g. default detergent/softener dosing on a washer) even while reporting remote control off. By default, LocalThings blocks every write with a clear error whenever a device reports remote control off, rather than letting the device silently reject it. Only enable this if you've confirmed writes actually work on this device with remote control off -- otherwise you'll trade that clear error for a silent failure.",
|
||||
"data": {
|
||||
"bypass_remote_control_lock": "Allow writes even when remote control is reported off"
|
||||
}
|
||||
}
|
||||
}
|
||||
},
|
||||
"issues": {
|
||||
"device_gap": {
|
||||
"title": "Incomplete capability coverage for {device_name}",
|
||||
|
||||
Reference in new issue