Add device support for Bespoke Window AC (issue #87)
The AW06C7155EWAZ window air conditioner (modelNum TP1X_DA_AC_WAC_01001_0000) reports no oneUiVersion and uses the '_WAC_' (Window Air Conditioner) modelNum token instead of the '_RAC_'/'_PRAC_' tokens already handled by for_device_by_model. Add a fallback rule for that token, routing it to the existing airconditioner registry. The device's resource surface (mode/convenient/wind/temperature/power/ filter/humidity) is already fully modeled by the airconditioner capability set, so this is purely a detection-routing fix -- confirmed against the issue #87 diagnostics dump with zero unbound hrefs.
This commit is contained in:
5 files changed
+580
No files matched your search
@@ -122,6 +122,15 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
# resource (see airconditioner.py's _AC_IGNORED).
|
||||
if key is None and '-CAWW-' in (model_num or '').upper():
|
||||
key = 'airconditioner'
|
||||
# Window air conditioners (e.g. TP1X_DA_AC_WAC_01001_0000, issue #87)
|
||||
# report no oneUiVersion and carry the '_WAC_' (Window Air Conditioner)
|
||||
# token instead of '_RAC_'/'_PRAC_'. Same TP1X-class resource surface
|
||||
# as the room-AC models above (mode/convenient/wind/temperature/power/
|
||||
# filter/humidity all confirmed against the issue #87 dump binding
|
||||
# cleanly against the existing airconditioner registry once routed
|
||||
# here) -- no WAC-specific resources needed.
|
||||
if key is None and '_WAC_' in (model_num or ''):
|
||||
key = 'airconditioner'
|
||||
# Air purifiers (e.g. ARTIK051_TVTL_18K, issue #56) report no
|
||||
# oneUiVersion either, and carry the '_TVTL_' board-family token.
|
||||
if key is None and '_TVTL_' in (model_num or ''):
|
||||
|
||||
Reference in new issue