fix: address code review feedback on issue-triage batch PR (#181, #183, #189, #196, #207, #208, #210)
common:
- Make KIDS_LOCK_GENERIC also a read-only BinarySensorDesc (device_class='lock'),
flipping value_fn to not bool(v) so /kidslock/0 value=False and
/kidslock/vs/0 kidsLock='Ready' render with the same polarity ('On'
means open/unlocked per HA's lock device class). The old SwitchDesc
form never honored device_class='lock' -- HA's switch platform only
accepts 'outlet'/'switch' -- so the surface was a plain switch whose
'On' meaning drifted across boards. Tests updated.
air_monitor:
- Add state_class='measurement' to dust/fine_dust/super_fine_dust so
the readings feed HA long-term statistics (co2 already had it).
- Import _AIR_QUALITY_SENSORS from air_purifier instead of duplicating
it byte-for-byte; update common.sensor_item_value's docstring to
mention the third caller.
by_type/__init__: drop trailing whitespace on the new 'ASM' line.
translations/en.json + nl.json: move the new 'dnd' switch entry to its
correct alphabetical position (after display_light, before fast_preheat).
SKILL.md: add an explicit read-side rule to §5's educated-guesses
section -- guessed unit/device_class/state_class on a SensorDesc
silently mislabels readings forever with no 4.xx to catch it (unlike
guessed writes, which the device rejects). The prior air_monitor
docstring cited this carve-out as if it existed; now it does.
tests/water_purifier (issue #196): change the ailite fixture's
favorite.defaultTemperature from '85' to '50' so the test actually
reproduces the reported bug -- '50' is in showList only, so a
descriptor reading from supportedList would fail the assertion that
the current default is in its options list.
This commit is contained in:
1 parent
a7d57086e9
commit
b7d3f86ec7
9 files changed
+83
-56
No files matched your search
@@ -297,6 +297,22 @@ to cross-check (temperature scale, minutes vs. seconds) — being
|
||||
syntactically valid but semantically backwards is exactly the case a
|
||||
rejection won't catch.
|
||||
|
||||
The same unit caveat applies on the **read** side, but with a sharper
|
||||
failure mode: a guessed `unit`, `device_class`, or `state_class` on a
|
||||
`SensorDesc` silently mislabels the entity in HA forever (every reading,
|
||||
every graph, every long-term statistic), with no 4.xx to catch it. The
|
||||
write-rejection safety net above doesn't cover reads — the device happily
|
||||
returns whatever it returns. So the read-side equivalent of "bind a write
|
||||
to the device's own reported range/supported-list" is: leave `unit`/
|
||||
`device_class`/`state_class` unset when the dump gives no field that
|
||||
nominates one (no `supportedGrades`, no second dump to compare against,
|
||||
no family member whose same field is already mapped). Match an
|
||||
already-bound descriptor on a sibling family when the underlying field
|
||||
and value shape are identical; otherwise expose the reading without an
|
||||
HA-level interpretation and let a future reporter or dump confirm it.
|
||||
See `air_monitor.AIR_QUALITY`'s docstring for the worked example
|
||||
(three dust keys, no `device_class`, no `unit`).
|
||||
|
||||
Still never invent an entity or a write from nothing: an opaque encoded
|
||||
blob with no supported-values field, no range, and no idle-vs-active diff
|
||||
to compare against is a gap for a human, not a guess — leave it unbound, or
|
||||
|
||||
Reference in new issue