fix: address code review feedback on issue-triage batch PR (#181, #183, #189, #196, #207, #208, #210)
common:
- Make KIDS_LOCK_GENERIC also a read-only BinarySensorDesc (device_class='lock'),
flipping value_fn to not bool(v) so /kidslock/0 value=False and
/kidslock/vs/0 kidsLock='Ready' render with the same polarity ('On'
means open/unlocked per HA's lock device class). The old SwitchDesc
form never honored device_class='lock' -- HA's switch platform only
accepts 'outlet'/'switch' -- so the surface was a plain switch whose
'On' meaning drifted across boards. Tests updated.
air_monitor:
- Add state_class='measurement' to dust/fine_dust/super_fine_dust so
the readings feed HA long-term statistics (co2 already had it).
- Import _AIR_QUALITY_SENSORS from air_purifier instead of duplicating
it byte-for-byte; update common.sensor_item_value's docstring to
mention the third caller.
by_type/__init__: drop trailing whitespace on the new 'ASM' line.
translations/en.json + nl.json: move the new 'dnd' switch entry to its
correct alphabetical position (after display_light, before fast_preheat).
SKILL.md: add an explicit read-side rule to §5's educated-guesses
section -- guessed unit/device_class/state_class on a SensorDesc
silently mislabels readings forever with no 4.xx to catch it (unlike
guessed writes, which the device rejects). The prior air_monitor
docstring cited this carve-out as if it existed; now it does.
tests/water_purifier (issue #196): change the ailite fixture's
favorite.defaultTemperature from '85' to '50' so the test actually
reproduces the reported bug -- '50' is in showList only, so a
descriptor reading from supportedList would fail the assertion that
the current default is in its options list.
This commit is contained in:
1 parent
a7d57086e9
commit
b7d3f86ec7
9 files changed
+83
-56
No files matched your search
@@ -297,6 +297,22 @@ to cross-check (temperature scale, minutes vs. seconds) — being
|
|||||||
syntactically valid but semantically backwards is exactly the case a
|
syntactically valid but semantically backwards is exactly the case a
|
||||||
rejection won't catch.
|
rejection won't catch.
|
||||||
|
|
||||||
|
The same unit caveat applies on the **read** side, but with a sharper
|
||||||
|
failure mode: a guessed `unit`, `device_class`, or `state_class` on a
|
||||||
|
`SensorDesc` silently mislabels the entity in HA forever (every reading,
|
||||||
|
every graph, every long-term statistic), with no 4.xx to catch it. The
|
||||||
|
write-rejection safety net above doesn't cover reads — the device happily
|
||||||
|
returns whatever it returns. So the read-side equivalent of "bind a write
|
||||||
|
to the device's own reported range/supported-list" is: leave `unit`/
|
||||||
|
`device_class`/`state_class` unset when the dump gives no field that
|
||||||
|
nominates one (no `supportedGrades`, no second dump to compare against,
|
||||||
|
no family member whose same field is already mapped). Match an
|
||||||
|
already-bound descriptor on a sibling family when the underlying field
|
||||||
|
and value shape are identical; otherwise expose the reading without an
|
||||||
|
HA-level interpretation and let a future reporter or dump confirm it.
|
||||||
|
See `air_monitor.AIR_QUALITY`'s docstring for the worked example
|
||||||
|
(three dust keys, no `device_class`, no `unit`).
|
||||||
|
|
||||||
Still never invent an entity or a write from nothing: an opaque encoded
|
Still never invent an entity or a write from nothing: an opaque encoded
|
||||||
blob with no supported-values field, no range, and no idle-vs-active diff
|
blob with no supported-values field, no range, and no idle-vs-active diff
|
||||||
to compare against is a gap for a human, not a guess — leave it unbound, or
|
to compare against is a gap for a human, not a guess — leave it unbound, or
|
||||||
|
|||||||
@@ -114,7 +114,7 @@ _BOARD_TOKEN_TO_KEY: dict[str, str] = {
|
|||||||
'VSKR': 'vacuum_station', # issue #131 -- stick-vacuum clean station
|
'VSKR': 'vacuum_station', # issue #131 -- stick-vacuum clean station
|
||||||
'DF': 'air_dresser', # issue #162
|
'DF': 'air_dresser', # issue #162
|
||||||
'VSWW': 'vacuum_station', # issue #219
|
'VSWW': 'vacuum_station', # issue #219
|
||||||
'ASM': 'air_monitor', # issue #210 -- Air Monitor Plus
|
'ASM': 'air_monitor', # issue #210 -- Air Monitor Plus
|
||||||
}
|
}
|
||||||
|
|
||||||
_TOKEN_SPLIT_RE = re.compile(r'[^A-Z0-9]+')
|
_TOKEN_SPLIT_RE = re.compile(r'[^A-Z0-9]+')
|
||||||
|
|||||||
@@ -19,40 +19,32 @@ rule. Same reasoning `air_purifier.AIR_QUALITY` already applies to this
|
|||||||
shape; index 0 is the only slot any family has ever read.
|
shape; index 0 is the only slot any family has ever read.
|
||||||
|
|
||||||
Dust/FineDust/SuperFineDust aren't assigned an HA `device_class`
|
Dust/FineDust/SuperFineDust aren't assigned an HA `device_class`
|
||||||
(pm10/pm25/pm1) despite the values reading like plausible ug/m3
|
(pm10/pm25/pm1) or `unit` despite the values reading like plausible
|
||||||
particulate readings in a physically consistent order (coarser >= finer):
|
ug/m3 particulate readings in a physically consistent order (coarser
|
||||||
Samsung's own two-tier Korean convention (i.e. "fine dust"/"ultra-fine
|
>= finer): Samsung's own two-tier Korean convention (i.e. "fine dust"/
|
||||||
dust") maps only to a PM10/PM2.5 pair, and this board's three-tier
|
"ultra-fine dust") maps only to a PM10/PM2.5 pair, and this board's
|
||||||
naming doesn't confirm where the extra tier or a PM1 reading actually
|
three-tier naming doesn't confirm where the extra tier or a PM1 reading
|
||||||
fits. Guessing wrong here would silently mislabel what unit a user reads
|
actually fits. The adding-device-support skill's read-side rule says
|
||||||
on a graph forever, not just fail one write -- the "worst case is
|
leave unit/device_class unset when the dump gives no field that
|
||||||
rejected" case for a flagged write guess doesn't cover a read-side
|
nominates one -- a wrong guess would silently mislabel every reading
|
||||||
device_class/unit guess, per the skill's own carve-out. Exposed as plain
|
forever, and the write-side rejection safety net doesn't cover reads.
|
||||||
measurement sensors named after the device's own field instead (matching
|
Exposed as plain `measurement` sensors named after the device's own
|
||||||
air_purifier.AIR_QUALITY's existing precedent).
|
field instead (matching air_purifier.AIR_QUALITY's existing precedent).
|
||||||
"""
|
"""
|
||||||
from datetime import time as dt_time
|
from datetime import time as dt_time
|
||||||
|
|
||||||
from ..capability import Capability
|
from ..capability import Capability
|
||||||
from ..entities import BinarySensorDesc, SensorDesc, SwitchDesc, TimeDesc
|
from ..entities import BinarySensorDesc, SensorDesc, SwitchDesc, TimeDesc
|
||||||
|
from .air_purifier import _AIR_QUALITY_SENSORS
|
||||||
from .common import int_or_none, sensor_item_value
|
from .common import int_or_none, sensor_item_value
|
||||||
|
|
||||||
_AIR_QUALITY_SENSORS = (
|
|
||||||
('dust', 'mdi:blur', 'Dust'),
|
|
||||||
('fine_dust', 'mdi:blur', 'FineDust'),
|
|
||||||
('super_fine_dust', 'mdi:blur', 'SuperFineDust'),
|
|
||||||
('odor', 'mdi:scent', 'Odor'),
|
|
||||||
('clean_level', 'mdi:air-filter', 'CleanLevel'),
|
|
||||||
)
|
|
||||||
|
|
||||||
SENSORS = Capability(
|
SENSORS = Capability(
|
||||||
href='/sensors/vs/0',
|
href='/sensors/vs/0',
|
||||||
poll_tier='warm',
|
poll_tier='warm',
|
||||||
entities=tuple(
|
entities=tuple(
|
||||||
# No state_class here, matching air_purifier.AIR_QUALITY's existing
|
|
||||||
# descriptors exactly -- these keys are shared catalog entries with
|
|
||||||
# that capability, so the two should behave identically.
|
|
||||||
SensorDesc(key=key, field='x.com.samsung.da.items', icon=icon,
|
SensorDesc(key=key, field='x.com.samsung.da.items', icon=icon,
|
||||||
|
state_class='measurement',
|
||||||
value_fn=lambda items, t=sensor_type: sensor_item_value(items, t))
|
value_fn=lambda items, t=sensor_type: sensor_item_value(items, t))
|
||||||
for key, icon, sensor_type in _AIR_QUALITY_SENSORS
|
for key, icon, sensor_type in _AIR_QUALITY_SENSORS
|
||||||
) + (
|
) + (
|
||||||
|
|||||||
@@ -228,8 +228,9 @@ def sensor_item_value(items, sensor_type, index=0):
|
|||||||
"""Pull one reading out of a `/sensors/vs/0`-style items[] list -- each
|
"""Pull one reading out of a `/sensors/vs/0`-style items[] list -- each
|
||||||
item is `{type, value: [...]}`; `index` picks which slot of a possibly
|
item is `{type, value: [...]}`; `index` picks which slot of a possibly
|
||||||
multi-value reading to read (index 0 is the raw measurement on every
|
multi-value reading to read (index 0 is the raw measurement on every
|
||||||
family seen so far). Shared by range_hood.AIR_QUALITY and
|
family seen so far). Shared by range_hood.AIR_QUALITY,
|
||||||
air_purifier.AIR_QUALITY, which read the same resource shape."""
|
air_purifier.AIR_QUALITY, and air_monitor.SENSORS, which all read the
|
||||||
|
same resource shape against the same {type, sensor_type} keys."""
|
||||||
for item in items or ():
|
for item in items or ():
|
||||||
if not isinstance(item, dict):
|
if not isinstance(item, dict):
|
||||||
continue
|
continue
|
||||||
@@ -301,11 +302,19 @@ POWER_VS_FALLBACK = Capability(
|
|||||||
KIDS_LOCK_GENERIC = Capability(
|
KIDS_LOCK_GENERIC = Capability(
|
||||||
href='/kidslock/0',
|
href='/kidslock/0',
|
||||||
entities=(
|
entities=(
|
||||||
SwitchDesc(key='child_lock', field='value',
|
# Read-only like KIDS_LOCK_VS_FALLBACK (issues #181/#183) -- not a
|
||||||
device_class='lock',
|
# SwitchDesc. SwitchDesc's `device_class='lock'` was never honored
|
||||||
value_fn=lambda v: bool(v),
|
# by HA (its switch platform only accepts 'outlet'/'switch'),
|
||||||
write_fn=lambda p, rep, href=None: (
|
# leaving a plain switch whose 'On' state meant different things
|
||||||
['kidslock', '0'], {'value': p == 'On'})),
|
# on different boards. As a BinarySensorDesc with `device_class='lock'`,
|
||||||
|
# both kids-lock surfaces read with the same polarity: 'On' means
|
||||||
|
# open/unlocked, per HA's lock device_class. The inversion in
|
||||||
|
# value_fn here (and in the fallback below) keeps the on-the-wire
|
||||||
|
# truth (value=False on /kidslock/0, kidsLock='Ready' on /kidslock/vs/0
|
||||||
|
# both mean kids lock NOT active) consistent with that polarity.
|
||||||
|
BinarySensorDesc(key='child_lock', field='value',
|
||||||
|
device_class='lock',
|
||||||
|
value_fn=lambda v: not bool(v)),
|
||||||
),
|
),
|
||||||
)
|
)
|
||||||
|
|
||||||
@@ -320,12 +329,12 @@ KIDS_LOCK_VS_FALLBACK = Capability(
|
|||||||
# confirmed this directly: writing the *correct* value ('Run')
|
# confirmed this directly: writing the *correct* value ('Run')
|
||||||
# still 4.05s, and the SmartThings app itself has no control for
|
# still 4.05s, and the SmartThings app itself has no control for
|
||||||
# it either -- the resource is genuinely read-only on this
|
# it either -- the resource is genuinely read-only on this
|
||||||
# hardware, not just wrong-valued. binary_sensor's 'lock' device
|
# hardware, not just wrong-valued. Polarity matches
|
||||||
# class is inverted from the switch reading below it used to be:
|
# KIDS_LOCK_GENERIC above -- 'On' means open/unlocked, so
|
||||||
# On means open/unlocked, so value_fn flips to `v == 'Ready'`.
|
# kidsLock='Ready' (kids lock NOT active) renders as 'On'.
|
||||||
BinarySensorDesc(key='child_lock', field='x.com.samsung.da.kidsLock',
|
BinarySensorDesc(key='child_lock', field='x.com.samsung.da.kidsLock',
|
||||||
device_class='lock',
|
device_class='lock',
|
||||||
value_fn=lambda v: v == 'Ready'),
|
value_fn=lambda v: v == 'Ready'),
|
||||||
),
|
),
|
||||||
)
|
)
|
||||||
|
|
||||||
|
|||||||
@@ -1008,12 +1008,12 @@
|
|||||||
"defrost_delay": {
|
"defrost_delay": {
|
||||||
"name": "Defrost delay"
|
"name": "Defrost delay"
|
||||||
},
|
},
|
||||||
"dnd": {
|
|
||||||
"name": "Do not disturb"
|
|
||||||
},
|
|
||||||
"display_light": {
|
"display_light": {
|
||||||
"name": "Display light"
|
"name": "Display light"
|
||||||
},
|
},
|
||||||
|
"dnd": {
|
||||||
|
"name": "Do not disturb"
|
||||||
|
},
|
||||||
"fast_preheat": {
|
"fast_preheat": {
|
||||||
"name": "Fast preheat"
|
"name": "Fast preheat"
|
||||||
},
|
},
|
||||||
|
|||||||
@@ -1008,12 +1008,12 @@
|
|||||||
"defrost_delay": {
|
"defrost_delay": {
|
||||||
"name": "Ontdooien uitstellen"
|
"name": "Ontdooien uitstellen"
|
||||||
},
|
},
|
||||||
"dnd": {
|
|
||||||
"name": "Niet storen"
|
|
||||||
},
|
|
||||||
"display_light": {
|
"display_light": {
|
||||||
"name": "Displayverlichting"
|
"name": "Displayverlichting"
|
||||||
},
|
},
|
||||||
|
"dnd": {
|
||||||
|
"name": "Niet storen"
|
||||||
|
},
|
||||||
"fast_preheat": {
|
"fast_preheat": {
|
||||||
"name": "Snel voorverwarmen"
|
"name": "Snel voorverwarmen"
|
||||||
},
|
},
|
||||||
|
|||||||
+1
-1
@@ -166,7 +166,7 @@
|
|||||||
"href": "/favorite/hotwater/vs/0",
|
"href": "/favorite/hotwater/vs/0",
|
||||||
"rep": {
|
"rep": {
|
||||||
"x.com.samsung.da.favorite.revision": "0",
|
"x.com.samsung.da.favorite.revision": "0",
|
||||||
"x.com.samsung.da.favorite.defaultTemperature": "85",
|
"x.com.samsung.da.favorite.defaultTemperature": "50",
|
||||||
"x.com.samsung.da.favorite.showList": [
|
"x.com.samsung.da.favorite.showList": [
|
||||||
"40",
|
"40",
|
||||||
"50",
|
"50",
|
||||||
|
|||||||
@@ -232,13 +232,19 @@ class TestWmSetinfoFlags:
|
|||||||
|
|
||||||
|
|
||||||
class TestKidsLockFallback:
|
class TestKidsLockFallback:
|
||||||
def test_generic_read_write(self):
|
def test_generic_is_read_only(self):
|
||||||
|
"""Issues #181/#183: the kids-lock resource is read-only on real
|
||||||
|
hardware (writing the *correct* value still 4.05s, and no
|
||||||
|
SwitchDesc device_class='lock' is honored by HA -- the switch
|
||||||
|
platform only accepts 'outlet'/'switch'). KIDS_LOCK_GENERIC and
|
||||||
|
KIDS_LOCK_VS_FALLBACK now share the same shape (BinarySensorDesc,
|
||||||
|
device_class='lock', same key) so both surfaces render with the
|
||||||
|
same polarity: 'On' means open/unlocked."""
|
||||||
assert common.KIDS_LOCK_GENERIC.href == '/kidslock/0'
|
assert common.KIDS_LOCK_GENERIC.href == '/kidslock/0'
|
||||||
desc = common.KIDS_LOCK_GENERIC.entities[0]
|
desc = common.KIDS_LOCK_GENERIC.entities[0]
|
||||||
assert desc.value_fn(True) is True
|
assert isinstance(desc, BinarySensorDesc)
|
||||||
path, body = desc.write_fn('On', {})
|
assert desc.value_fn(False) is True # value=False -> On=Unlocked
|
||||||
assert path == ['kidslock', '0']
|
assert desc.value_fn(True) is False # value=True -> Off=Locked
|
||||||
assert body == {'value': True}
|
|
||||||
|
|
||||||
def test_vs_fallback_gated(self):
|
def test_vs_fallback_gated(self):
|
||||||
assert common.KIDS_LOCK_VS_FALLBACK.match_fn({}, {'/kidslock/vs/0': {}}) is True
|
assert common.KIDS_LOCK_VS_FALLBACK.match_fn({}, {'/kidslock/vs/0': {}}) is True
|
||||||
|
|||||||
@@ -370,21 +370,25 @@ def test_ailite_hot_water_temperature_gated_off_without_supported_list():
|
|||||||
|
|
||||||
|
|
||||||
def test_ailite_favorite_hotwater_temperature_options_include_the_custom_value():
|
def test_ailite_favorite_hotwater_temperature_options_include_the_custom_value():
|
||||||
"""This board's real dump (issue #196) is the concrete case: the user
|
"""Issue #196's concrete failure case: the user added a custom 50C value
|
||||||
added a custom 50C value via the SmartThings app's "temperatures to
|
via the SmartThings app's "temperatures to display" editor, so the
|
||||||
display" editor, so favorite.showList is
|
board's defaultTemperature is now '50'. showList contains '50'
|
||||||
['40', '50', '75', '85', '90'] while favorite.supportedList stays the
|
([40, 50, 75, 85, 90]) but supportedList does NOT (still the fixed
|
||||||
fixed ['40', '75', '85', '90'] -- '50' only ever appears in showList.
|
[40, 75, 85, 90]). Reading options_field='x.com.samsung.da.favorite.supportedList'
|
||||||
Whichever of the two the descriptor reads from, a default temperature
|
-- the old behavior -- would register a select whose options list
|
||||||
of '50' would render as HA's 'unknown' state unless that field's raw
|
doesn't contain the current default, so HA would render the entity as
|
||||||
option list actually contains '50'."""
|
'unknown'. The descriptor must read from showList so '50' is in
|
||||||
|
options."""
|
||||||
desc = _desc_ailite('favorite_hotwater_temperature')
|
desc = _desc_ailite('favorite_hotwater_temperature')
|
||||||
assert desc.options_field == 'x.com.samsung.da.favorite.showList'
|
assert desc.options_field == 'x.com.samsung.da.favorite.showList'
|
||||||
_, resources = _water_purifier_ailite()
|
_, resources = _water_purifier_ailite()
|
||||||
rep = resources['/favorite/hotwater/vs/0']
|
rep = resources['/favorite/hotwater/vs/0']
|
||||||
assert rep['x.com.samsung.da.favorite.defaultTemperature'] in rep[desc.options_field]
|
# defaultTemperature='50' must be a member of the field the descriptor
|
||||||
|
# actually reads -- this is the precise assertion that would fail under
|
||||||
|
# the old supportedList behavior.
|
||||||
|
assert rep['x.com.samsung.da.favorite.defaultTemperature'] == '50'
|
||||||
|
assert '50' in rep[desc.options_field]
|
||||||
assert '50' not in rep['x.com.samsung.da.favorite.supportedList']
|
assert '50' not in rep['x.com.samsung.da.favorite.supportedList']
|
||||||
assert '50' in rep['x.com.samsung.da.favorite.showList']
|
|
||||||
|
|
||||||
|
|
||||||
def test_ailite_sound_mode_options_come_from_live_supported_modes():
|
def test_ailite_sound_mode_options_come_from_live_supported_modes():
|
||||||
|
|||||||
Reference in new issue