Fix AC coverage for TP1X-class (oneUiVersion "7.0 Air conditioner")

This commit is contained in:
paddawan2002 committed 2026-07-22 11:26:01 +02:00
1 parent 10f2aac0bd
commit bc9d4f4cf5
7 files changed
+758 -8

No files matched your search

+18
View File
@@ -153,6 +153,24 @@ def test_registry_reproduces_golden_state_keys_for_tp2x_ref_20k():
)
def test_registry_reproduces_golden_state_keys_for_ac_tp1x_da_ac_rac_01011():
"""Newer AC firmware (Tizen Lite, oneUiVersion "7.0 Air conditioner"; model
TP1X_DA-AC-RAC-01011) reports temperature via the vendor /temperatures/vs/0
items[] resource and adds a /light/vs/0 display light, with 13 extra vendor
housekeeping hrefs -- issue #17 for this model class."""
from tests.conftest import _load_device
resources = _load_device('airconditioner_tp1x_da_ac_rac_01011')
golden = json.loads(
(GOLDEN / 'airconditioner_tp1x_da_ac_rac_01011.json').read_text()
)
state_keys = _new_state_keys('airconditioner_tp1x_da_ac_rac_01011', resources)
assert set(state_keys) == set(golden['state_keys']), (
f"state_keys mismatch:\n"
f" extra: {sorted(set(state_keys) - set(golden['state_keys']))}\n"
f" missing: {sorted(set(golden['state_keys']) - set(state_keys))}"
)
def test_resources_from_batch_preferred_over_flat():
from tests.conftest import _resources_from_dump
dump = {