fix: normalize washer dosing-select codes; stop blocking the loop in diagnostics (#9)

Two fixes for issue #9 (WW90T634DHE washer):

- washer dosing selects: the four detergent/softener dosing selects read their
  current value from `<Prefix>LevelCtrl_<code>` (un-padded, e.g. "3") but their
  options from `Supported<Prefix>LevelCtrl_<hexpairs>` (zero-padded, e.g. "03").
  HA's SelectEntity renders a select "unknown" whenever current_option is not in
  options, so all four sat "unknown" (idle and running) even though every other
  select worked -- which is why it was only those four. Normalize the current
  value to the supported code with the same integer value so it matches an
  option (and its translation); convert back to the device's native un-padded
  format on write.

- diagnostics: pkg_version("smartthings-local") reads package metadata off disk
  (listdir + open + read_text), tripping HA's event-loop blocking-call detector.
  Offload it to the executor. Audited the rest of the package: config_flow's
  socket/crypto and every coordinator DTLS call are already offloaded via
  async_add_executor_job -- this was the only blocking call left on the loop.

Also documents air-conditioner support in the README (device table, capability
module list, platform list), missed when that support landed.

Updates the washer dosing tests to the corrected value/write format and adds a
current-option-is-a-valid-option regression; adds a diagnostics test asserting
the version lookup runs off the event loop.
This commit is contained in:
Marc Billow committed 2026-07-21 23:49:30 +00:00
1 parent bedc662b47
commit c0298d57d9
5 files changed
+109 -19

No files matched your search

+6 -1
View File
@@ -26,13 +26,18 @@ async def async_get_config_entry_diagnostics(
coordinator: LocalThingsCoordinator = hass.data[DOMAIN][entry.entry_id]
integration = await async_get_integration(hass, DOMAIN)
# importlib.metadata.version() reads the installed package's metadata off
# disk (listdir + open + read_text), which trips HA's event-loop blocking
# detector when called inline here. Offload it to the executor.
stl_version = await hass.async_add_executor_job(pkg_version, "smartthings-local")
return {
"device_type": coordinator.device_type_name or "unknown",
"one_ui_version": coordinator.one_ui_version,
"unbound_hrefs": sorted(coordinator._unbound_hrefs),
"resources": redact_resources(coordinator.last_resources),
"integration_version": integration.version,
"smartthings_local_version": pkg_version("smartthings-local"),
"smartthings_local_version": stl_version,
"observe_mode": coordinator.observe_mode,
"observe_subscribed_hrefs": sorted(coordinator._observe.subscribed_hrefs),
"observe_fallback_hrefs": sorted(coordinator._observe.fallback_hrefs),
@@ -160,13 +160,50 @@ def _level_options(prefix):
return lambda resources: _supported_level_options(resources, prefix)
def _dosing_level(prefix):
"""Current dose code, normalized to the `Supported<prefix>` code format.
The device reports the selected level as `<prefix>_<code>` with the code
un-padded (e.g. '3'), but the valid codes -- which are also this select's
options and its translation keys -- come from `Supported<prefix>_<hexpairs>`
as zero-padded hex pairs (e.g. '03'). Left as '3', the current value sits
outside the select's own option list, so HA renders it 'unknown' (issue #9).
Resolve it to the supported code with the same integer value so
current_option matches an option (and its translation)."""
def fn(rep):
opts = rep.get('x.com.samsung.da.options')
raw = option_value(opts, prefix)
if raw is None:
return None
supported_raw = option_value(opts, f'Supported{prefix}')
try:
target = int(raw, 16)
except (TypeError, ValueError):
return raw
for code in hex_pairs(supported_raw) if supported_raw else []:
try:
if int(code, 16) == target:
return code
except (TypeError, ValueError):
continue
return raw
return fn
def _level_write(prefix):
def write(p, rep, href=None):
opts = list(rep.get('x.com.samsung.da.options') or [])
if not opts:
return None
# `p` is the zero-padded supported code the UI selected (e.g. '03');
# the device stores the level un-padded (e.g. '3'), matching how it
# reports it, so write it back in that native shape.
try:
native = format(int(p, 16), 'X')
except (TypeError, ValueError):
native = p
return ['course', 'vs', '0'], {
'x.com.samsung.da.options': replace_in_options(opts, prefix, p),
'x.com.samsung.da.options': replace_in_options(opts, prefix, native),
}
return write
@@ -201,8 +238,7 @@ WASHER_COURSE = Capability(
options=_level_options('DetergentLevelCtrl'),
exists_fn=lambda rep, resources: bool(
_level_options('DetergentLevelCtrl')(resources)),
rep_fn=lambda rep: option_value(
rep.get('x.com.samsung.da.options'), 'DetergentLevelCtrl'),
rep_fn=_dosing_level('DetergentLevelCtrl'),
write_fn=_level_write('DetergentLevelCtrl')),
SelectDesc(key='detergent_water_hardness', name='Detergent water hardness',
icon='mdi:water-opacity',
@@ -211,8 +247,7 @@ WASHER_COURSE = Capability(
options=_level_options('DetergentLevel2Ctrl'),
exists_fn=lambda rep, resources: bool(
_level_options('DetergentLevel2Ctrl')(resources)),
rep_fn=lambda rep: option_value(
rep.get('x.com.samsung.da.options'), 'DetergentLevel2Ctrl'),
rep_fn=_dosing_level('DetergentLevel2Ctrl'),
write_fn=_level_write('DetergentLevel2Ctrl')),
SelectDesc(key='softener_quantity', name='Softener quantity', icon='mdi:flask-outline',
translation_key='washer_dosing_quantity',
@@ -220,8 +255,7 @@ WASHER_COURSE = Capability(
options=_level_options('SoftenerLevelCtrl'),
exists_fn=lambda rep, resources: bool(
_level_options('SoftenerLevelCtrl')(resources)),
rep_fn=lambda rep: option_value(
rep.get('x.com.samsung.da.options'), 'SoftenerLevelCtrl'),
rep_fn=_dosing_level('SoftenerLevelCtrl'),
write_fn=_level_write('SoftenerLevelCtrl')),
SelectDesc(key='softener_concentration', name='Softener concentration',
icon='mdi:flask-plus-outline',
@@ -230,8 +264,7 @@ WASHER_COURSE = Capability(
options=_level_options('SoftenerLevel2Ctrl'),
exists_fn=lambda rep, resources: bool(
_level_options('SoftenerLevel2Ctrl')(resources)),
rep_fn=lambda rep: option_value(
rep.get('x.com.samsung.da.options'), 'SoftenerLevel2Ctrl'),
rep_fn=_dosing_level('SoftenerLevel2Ctrl'),
write_fn=_level_write('SoftenerLevel2Ctrl')),
BinarySensorDesc(key='detergent_low', name='Detergent low',