docs: de-identify reporter usernames repo-wide, add PII rule to skill

Extended the earlier de-identification (jhkwon19) to the other issue #177
reporter (HJcom), who was named in ~20 spots across coordinator.py,
diagnostics.py, subdevices.py, identity.py, capabilities/airconditioner.py,
a fixture's seeds_note, and several test docstrings/function names. Swapped
all of it for "the reporter"/"the Pattern A reporter", matching the
convention already established for the other reporter.

Added a rule to the adding-device-support skill (end of "Lock it in"):
don't put a reporter's name or GitHub username in code comments,
docstrings, seeds_note, or test/function names -- that prose ships and
sits in git history indefinitely, unlike an issue thread or a
release-notes thank-you. Use "the reporter" / "issue #NNN's reporter" /
a pattern label instead.
This commit is contained in:
Marc Billow committed 2026-07-30 03:06:06 +00:00
1 parent ce92d71a92
commit ca27bf7f6e
11 files changed
+121 -97

No files matched your search

@@ -2029,5 +2029,5 @@
"x.com.samsung.da.numofsubdevice": "2"
}
},
"seeds_note": "ALL REAL CAPTURED DATA -- issue #177, HJcom's ARTIK051_DONGLE_FAC_18K (Samsung 2-in-1: floor-standing master + wall-mounted second indoor subdevice). device0, oic_res and both /device/<n> seeds come verbatim from their v0.16.0 diagnostics download, which is the first release that probes /device/1 and /device/2. Nothing here is reconstructed. The reporter masked a handful of values in their own dump before posting (serialNum, and the airflow `direction` / vendor `humidity` readings); those are normalized onto this repo's usual **REDACTED** marker. /device/1 is the real second subdevice -- populated power/mode/temperature and its own /information/vs/1 reporting ARTIK051_DONGLE_FAC_RAC_18K (RAC = the wall-mounted subdevice) against the master's ARTIK051_DONGLE_FAC_18K. /device/2 answers with the same 14-href shape but every state rep is empty {} -- it is the unused third slot SmartThings shows disabled, and it is why subdevice materialization gates on populated climate state rather than on a seed merely answering. `probes` is not part of any batch response: /multidevice/vs/0 is listed in oic_res but absent from /device/0's batch, and the reporter read it by hand through the debug panel (a write attempt returned CoAP 4.00, i.e. read-only). Its numofsubdevice=2 independently corroborates 2 real subdevices, not 3."
"seeds_note": "ALL REAL CAPTURED DATA -- issue #177, the reporter's ARTIK051_DONGLE_FAC_18K (Samsung 2-in-1: floor-standing master + wall-mounted second indoor subdevice). device0, oic_res and both /device/<n> seeds come verbatim from their v0.16.0 diagnostics download, which is the first release that probes /device/1 and /device/2. Nothing here is reconstructed. The reporter masked a handful of values in their own dump before posting (serialNum, and the airflow `direction` / vendor `humidity` readings); those are normalized onto this repo's usual **REDACTED** marker. /device/1 is the real second subdevice -- populated power/mode/temperature and its own /information/vs/1 reporting ARTIK051_DONGLE_FAC_RAC_18K (RAC = the wall-mounted subdevice) against the master's ARTIK051_DONGLE_FAC_18K. /device/2 answers with the same 14-href shape but every state rep is empty {} -- it is the unused third slot SmartThings shows disabled, and it is why subdevice materialization gates on populated climate state rather than on a seed merely answering. `probes` is not part of any batch response: /multidevice/vs/0 is listed in oic_res but absent from /device/0's batch, and the reporter read it by hand through the debug panel (a write attempt returned CoAP 4.00, i.e. read-only). Its numofsubdevice=2 independently corroborates 2 real subdevices, not 3."
}