Add real fan-speed control for ARTIK051_TVTL air purifiers (issue #56)

/airflow/0's speed was left read-only because the first round of diagnostics
wasn't conclusive (0 for both Auto and High, 3 for Low/Medium and Sleep) --
likely because all five dumps were captured within about a minute of each
other, faster than this integration's own poll cycle could settle each
change. A second round, captured 60-90s apart per setting on two independent
units, confirmed a clean monotonic 0-4 mapping across Auto/Sleep/Low/Medium/
High instead.

Builds an ordered-speed fan off that confirmed range, the same SET_SPEED
shape as the range hood's fan -- this board never self-reports a
supportedModes-style label list, so there's no named-preset table to
preserve, just percentage steps over the raw code. /airflow/vs/0's vendor
speedLevel stays a read-only fallback since it was unreliable in that same
second round.
This commit is contained in:
Marc Billow committed 2026-07-27 21:32:44 +00:00
1 parent 7c68d478af
commit d4583b3240
4 files changed
+160 -20

No files matched your search

@@ -39,14 +39,23 @@ set to Auto/Sleep/Low/Medium/High):
automatic side effect of sleep mode, e.g. a
display-dimming level, but that's still a guess).
/airflow/0 and /airflow/vs/0's `speed` still isn't modeled as a real
fan-speed control: across the same five dumps it read 0 for both Auto *and*
High, and 3 for Low/Medium *and* Sleep -- not a monotonic mapping to any
selectable level, and the dumps were all captured within about three minutes
of each other (only one poll cycle apart at this integration's 30s summary
interval), so the values may not have settled after each change before the
diagnostics snapshot was taken. Exposed read-only pending a confirmed,
stable capture -- see the issue #56 discussion for what's needed.
/airflow/0's `speed` is now a real fan-speed control (issue #56 follow-up).
The first round of five dumps above wasn't conclusive -- it read 0 for both
Auto *and* High, and 3 for Low/Medium *and* Sleep, likely because all five
were captured within about a minute of each other, faster than this
integration's own ~30s poll cycle could settle each change. A second round,
captured 60-90s apart per setting on two independent units, confirmed a
clean monotonic mapping instead: Auto=0, Sleep=1, Low=2, Medium=3, High=4.
AIRFLOW_GENERIC below builds an ordered-speed fan off that confirmed 0-4
range -- same SET_SPEED shape as range_hood.py's fan, mapping HA's
percentage steps straight onto the raw code, no named-preset table needed
(unlike the TP1X family's FAN, which exposes real named modes because its
board actually reports a supportedModes list to hang names off of).
/airflow/vs/0's vendor `speedLevel` is NOT used for the same purpose -- it
was unreliable on both units in that second round (Low/Medium collided on
one unit, stuck at 0 throughout on the other), so AIRFLOW_VS_FALLBACK below
stays a plain read-only diagnostic even after this change.
"""
from ..capability import Capability
from ..entities import (
@@ -64,6 +73,7 @@ from .laundry import bool_option_exists, bool_option_value, option_value, option
# Both board generations share the /mode/vs/0 href, so FAN and MODE below
# are mutually exclusive via this presence check rather than colliding.
HREF_MODE = '/mode/vs/0'
HREF_AIRFLOW = '/airflow/0'
def _has_top_level_modes(rep, resources):
@@ -126,21 +136,44 @@ DEVICE_ACTIVE = Capability(
),
)
# OCF-native / vendor pair for fan speed+direction -- see module docstring for
# why these are read-only for now.
# Confirmed via issue #56's second, properly-spaced round of diagnostics
# (two independent units, 60-90s apart per setting): /airflow/0's `speed` is
# a clean, monotonic 0-4 code across Auto/Sleep/Low/Medium/High, so it now
# backs a real ordered-speed fan (fan.py's LocalThingsAirflowFan, same
# SET_SPEED shape as the range hood's) instead of a read-only sensor --
# no named-preset table needed, since HA's percentage steps map onto the
# raw 0-4 code directly, the same way the range hood's numeric levels do.
# `direction` stays a plain diagnostic: every dump seen (both rounds, both
# units) reads 'Off' for it regardless of fan setting, so there's nothing
# confirmed to control there yet.
def _airflow_fan_write(payload, rep, href=None):
kind, value, *args = payload
if kind == 'power':
power_href = args[0] if args else '/power/vs/0'
if power_href == '/power/0':
return ['power', '0'], {'value': bool(value)}
return (['power', 'vs', '0'],
{'x.com.samsung.da.power': 'On' if value else 'Off'})
if kind == 'speed':
return ['airflow', '0'], {'speed': int(value)}
return None
AIRFLOW_GENERIC = Capability(
href='/airflow/0',
poll_tier='warm',
entities=(
SensorDesc(key='fan_speed_level', field='speed',
icon='mdi:fan',
state_class='measurement', entity_category='diagnostic'),
FanDesc(key='fan', field='speed', write_fn=_airflow_fan_write),
SensorDesc(key='fan_direction', field='direction',
icon='mdi:rotate-3d-variant',
entity_category='diagnostic'),
),
)
# Left exactly as a read-only fallback -- speedLevel is NOT the same
# confirmed-reliable field as /airflow/0's speed above (see module
# docstring): it collided Low/Medium on one unit and stuck at 0 throughout
# on the other in the same properly-spaced round.
AIRFLOW_VS_FALLBACK = Capability(
href='/airflow/vs/0',
match_fn=lambda rep, resources: '/airflow/0' not in resources,