Add real fan-speed control for ARTIK051_TVTL air purifiers (issue #56)
/airflow/0's speed was left read-only because the first round of diagnostics wasn't conclusive (0 for both Auto and High, 3 for Low/Medium and Sleep) -- likely because all five dumps were captured within about a minute of each other, faster than this integration's own poll cycle could settle each change. A second round, captured 60-90s apart per setting on two independent units, confirmed a clean monotonic 0-4 mapping across Auto/Sleep/Low/Medium/ High instead. Builds an ordered-speed fan off that confirmed range, the same SET_SPEED shape as the range hood's fan -- this board never self-reports a supportedModes-style label list, so there's no named-preset table to preserve, just percentage steps over the raw code. /airflow/vs/0's vendor speedLevel stays a read-only fallback since it was unreliable in that same second round.
This commit is contained in:
4 files changed
+160
-20
No files matched your search
+1
-1
@@ -10,8 +10,8 @@
|
||||
"energy_last_month_kwh",
|
||||
"energy_saved_kwh",
|
||||
"energy_this_month_kwh",
|
||||
"fan",
|
||||
"fan_direction",
|
||||
"fan_speed_level",
|
||||
"filter_progress",
|
||||
"fine_dust",
|
||||
"odor",
|
||||
|
||||
@@ -41,7 +41,7 @@ def test_expected_entities_present():
|
||||
for key in (
|
||||
'power_switch', 'alarm_code', 'dust', 'fine_dust', 'super_fine_dust',
|
||||
'odor', 'clean_level', 'filter_progress', 'device_active',
|
||||
'diagnosis_status', 'fan_speed_level', 'fan_direction',
|
||||
'diagnosis_status', 'fan', 'fan_direction',
|
||||
'display_light', 'operating_mode',
|
||||
):
|
||||
assert key in state, key
|
||||
@@ -114,3 +114,27 @@ def test_airflow_vs_fallback_only_binds_without_generic():
|
||||
{}, {'/airflow/0': {'speed': 0, 'direction': 'Off'}},
|
||||
) is False
|
||||
assert air_purifier.AIRFLOW_VS_FALLBACK.match_fn({}, {}) is True
|
||||
|
||||
|
||||
def test_airflow_fan_write_contract():
|
||||
"""Confirmed via issue #56's second, properly-spaced diagnostics round
|
||||
(two independent units, 60-90s apart per setting): /airflow/0's `speed`
|
||||
is a clean, monotonic 0-4 code, so the write is a plain int passthrough
|
||||
-- no named-preset table needed (see fan.py's LocalThingsAirflowFan)."""
|
||||
fan_desc = next(e for e in air_purifier.AIRFLOW_GENERIC.entities if e.key == 'fan')
|
||||
assert fan_desc.write_fn(('speed', 3), {}) == (['airflow', '0'], {'speed': 3})
|
||||
assert fan_desc.write_fn(('power', True, '/power/vs/0'), {}) == (
|
||||
['power', 'vs', '0'], {'x.com.samsung.da.power': 'On'},
|
||||
)
|
||||
assert fan_desc.write_fn(('power', False, '/power/0'), {}) == (
|
||||
['power', '0'], {'value': False},
|
||||
)
|
||||
|
||||
|
||||
def test_airflow_speed_reads_from_dump():
|
||||
"""The fixture's /airflow/0 (power-off snapshot) reads speed=0, and
|
||||
fan_direction stays a plain diagnostic (every dump seen reads 'Off'
|
||||
regardless of fan setting)."""
|
||||
state = _state()
|
||||
assert state['fan'] == 0
|
||||
assert state['fan_direction'] == 'Off'
|
||||
Reference in new issue