Bind AI energy level on washer; switch/select split, drop translations

Issue #40: /energy/ailevel/vs/0 was unbound on a plain washer. The
capability already existed for fridges but was gated off entirely on
single-level hardware (the common case), so it's moved to common.py
(cross-family, like fridge + washer now) and split into two entities:
a switch when supportedAiLevel has exactly one entry (aiLevel is really
just an on/off toggle there), and a select otherwise, with '0' (off)
synthesized back into the select's options since supportedAiLevel never
lists it but it's a real observed value.

Also drops the translation_key/strings.json entries -- aiLevel's raw
digit values already render fine untranslated, and translating a
handful of levels can't cover devices with more.
This commit is contained in:
Marc Billow committed 2026-07-23 00:44:57 +00:00
1 parent 5d9b470d7e
commit d6639c99d4
12 files changed
+212 -80

No files matched your search

@@ -1,5 +1,6 @@
{
"state_keys": [
"ai_energy_level",
"alarm_code",
"autofill",
"cooler_setpoint",
+1
View File
@@ -1,5 +1,6 @@
{
"state_keys": [
"ai_energy_level",
"alarm_code",
"bubble_soak",
"buzzer_sound",
+15
View File
@@ -44,6 +44,21 @@
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/energy/ailevel/vs/0",
"rep": {
"aiLevel": "0",
"supportedAiLevel": [
"1"
],
"energySavingInfo": [
{
"aiLevel": "1",
"maxEnergySavingRate": "70"
}
]
}
},
{
"href": "/course/vs/0",
"rep": {