fix(washer,fridge,oven): correct energy/temperature-unit bugs from issues #6/#7
Washer (#6): instantaneousPower is a dead sentinel ('-500') on every TP1-class washer dump collected so far, and cumulativePower is absent outright on at least one model. WASHER_ENERGY_METER now hides both sensors instead of showing a misleading "0 W"/perpetual "unavailable". Fridge (#7): temperature sensors/setpoints hardcoded '°F', ignoring the unit each device actually reports per-reading -- fixed via a new unit_fn hook read live from the resource. Also corrects DEFROST_BLOCK_STATUS's polarity (DEFROST_BLOCK_ON means actively defrosting, not "blocked", confirmed against live dumps) and adds REFRIGERATION_FALLBACK for /refrigeration/0, closing the last unbound href surfaced by issue #7's diagnostic dump. Oven: applies the same live-unit-reading fix defensively to OVEN_SETPOINT, which shares the same aggregate resource shape.
This commit is contained in:
1 parent
e66f4fd2ff
commit
e875266405
16 files changed
+320
-26
No files matched your search
@@ -2,9 +2,13 @@
|
||||
|
||||
Resources verified against the dump at local-tools/dumps/10.0.0.254.json.
|
||||
|
||||
Temperature fields in all /temperature/* resources are in Fahrenheit on this
|
||||
model. Setpoints are NumberDesc with direct-write write_fn — generic caps
|
||||
derive the CoAP PUT path from href at write time.
|
||||
Temperature unit is read live from each resource, not assumed: the RF9000B
|
||||
dump reports Fahrenheit ("units": "F" / "x.com.samsung.da.unit": "Fahrenheit"),
|
||||
but a TP1X_REF_21K dump (issue #7) reports the same fields in Celsius for the
|
||||
exact same resources — the device tells you which one it is, it's just never
|
||||
been read before. See `_temp_unit`/`_temp_item_unit` below. Setpoints are
|
||||
NumberDesc with direct-write write_fn — generic caps derive the CoAP PUT path
|
||||
from href at write time.
|
||||
|
||||
Multi-instance note: the two door resources (/door/cooler/0 and
|
||||
/door/freezer/0) and the two ice-maker resources (/icemaker/one/vs/0 and
|
||||
@@ -18,6 +22,7 @@ from ..entities import (
|
||||
BinarySensorDesc, ButtonDesc, NumberDesc, SelectDesc, SensorDesc,
|
||||
SwitchDesc, TimeDesc,
|
||||
)
|
||||
from .common import normalize_temp_unit
|
||||
|
||||
# Display names for the beverage zone, flex zone, ice type, and
|
||||
# ice-making-status enums below live in strings.json / translations/en.json,
|
||||
@@ -33,6 +38,12 @@ def _int(v):
|
||||
return None
|
||||
|
||||
|
||||
def _temp_unit(rep):
|
||||
"""'units': 'C'/'F' (or 'Celsius'/'Fahrenheit') -> '°C'/'°F'. Defaults to
|
||||
°F (this module's original assumption) if the device omits the field."""
|
||||
return normalize_temp_unit(rep.get('units'))
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Temperature (generic — covers /temperature/current/* and /temperature/desired/*)
|
||||
# ---------------------------------------------------------------------------
|
||||
@@ -45,7 +56,7 @@ TEMP_CURRENT_GENERIC = Capability(
|
||||
entities=(
|
||||
SensorDesc(key='temperature', field='temperature',
|
||||
name=None, icon='mdi:thermometer',
|
||||
device_class='temperature', unit='°F',
|
||||
device_class='temperature', unit_fn=_temp_unit,
|
||||
state_class='measurement'),
|
||||
),
|
||||
)
|
||||
@@ -57,7 +68,7 @@ TEMP_SETPOINT_GENERIC = Capability(
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
NumberDesc(key='setpoint', field='temperature',
|
||||
name=None, device_class='temperature', unit='°F',
|
||||
name=None, device_class='temperature', unit_fn=_temp_unit,
|
||||
native_min=-20.0, native_max=50.0,
|
||||
range_field='range', entity_category='config',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
@@ -172,12 +183,16 @@ STATUS_LOCK = Capability(
|
||||
)
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Defrost delay
|
||||
# Defrost delay / active-defrost status
|
||||
#
|
||||
# /defrost/delay/vs/0 is the writable toggle. /defrost/block/vs/0 just
|
||||
# reports whether the defrost cycle is currently blocked as a result (a
|
||||
# derived status, not an independent control) — exposed as a read-only
|
||||
# diagnostic binary sensor.
|
||||
# /defrost/delay/vs/0 is the writable toggle to postpone a scheduled
|
||||
# defrost. /defrost/block/vs/0 is an unrelated, independently-varying
|
||||
# status: despite its "block" naming (originally assumed to mean "defrost
|
||||
# is being withheld"), live dumps confirm DEFROST_BLOCK_ON means the
|
||||
# defrost cycle is *actively running* right now, seen with defrost_delay
|
||||
# off -- i.e. "block" refers to the evaporator/coil block being defrosted,
|
||||
# not a blocking/prevention state. Exposed as a read-only diagnostic
|
||||
# binary sensor.
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
DEFROST_DELAY = Capability(
|
||||
@@ -198,8 +213,8 @@ DEFROST_BLOCK_STATUS = Capability(
|
||||
href='/defrost/block/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
BinarySensorDesc(key='defrost_blocked', field='x.com.samsung.da.modes',
|
||||
name='Defrost blocked', icon='mdi:snowflake-off',
|
||||
BinarySensorDesc(key='defrost_active', field='x.com.samsung.da.modes',
|
||||
name='Defrost active', icon='mdi:snowflake-melt',
|
||||
entity_category='diagnostic',
|
||||
value_fn=lambda modes: bool(modes) and modes[0] == 'DEFROST_BLOCK_ON'),
|
||||
),
|
||||
@@ -590,6 +605,13 @@ def _temp_item_value(items, keyword):
|
||||
return None
|
||||
|
||||
|
||||
def _temp_item_unit(items, keyword):
|
||||
for item in (items or []):
|
||||
if keyword.lower() in (item.get('x.com.samsung.da.description') or '').lower():
|
||||
return normalize_temp_unit(item.get('x.com.samsung.da.unit'))
|
||||
return '°F'
|
||||
|
||||
|
||||
TEMPERATURES_FALLBACK = Capability(
|
||||
href='/temperatures/vs/0',
|
||||
match_fn=lambda rep, resources: not _any_temperature_generic(resources),
|
||||
@@ -597,11 +619,15 @@ TEMPERATURES_FALLBACK = Capability(
|
||||
entities=(
|
||||
SensorDesc(key='freezer_temperature', field='x.com.samsung.da.items',
|
||||
name='Freezer temperature', icon='mdi:thermometer',
|
||||
device_class='temperature', unit='°F', state_class='measurement',
|
||||
device_class='temperature', state_class='measurement',
|
||||
unit_fn=lambda rep: _temp_item_unit(
|
||||
rep.get('x.com.samsung.da.items'), 'Freezer'),
|
||||
value_fn=lambda items: _temp_item_value(items, 'Freezer')),
|
||||
SensorDesc(key='fridge_temperature', field='x.com.samsung.da.items',
|
||||
name='Fridge temperature', icon='mdi:thermometer',
|
||||
device_class='temperature', unit='°F', state_class='measurement',
|
||||
device_class='temperature', state_class='measurement',
|
||||
unit_fn=lambda rep: _temp_item_unit(
|
||||
rep.get('x.com.samsung.da.items'), 'Fridge'),
|
||||
value_fn=lambda items: _temp_item_value(items, 'Fridge')),
|
||||
),
|
||||
)
|
||||
@@ -628,3 +654,34 @@ ICEMAKER_STATUS_FALLBACK = Capability(
|
||||
{'x.com.samsung.da.iceMaker': 'On' if p else 'Off'})),
|
||||
),
|
||||
)
|
||||
|
||||
# OCF-native /refrigeration/0 (issue #7's unbound_hrefs) -- the odd one out
|
||||
# in this section: its three fields duplicate two *different* richer
|
||||
# hrefs (REFRIGERATION's rapidFridge/rapidFreezing and
|
||||
# DEFROST_BLOCK_STATUS's defrost_active), each absent independently, so a
|
||||
# single capability-level match_fn can't express it. Gated per-entity
|
||||
# (exists_fn) instead: rapid_fridge/rapid_freezing back off only when
|
||||
# REFRIGERATION's href is present; defrost_active only when
|
||||
# DEFROST_BLOCK_STATUS's is. No write path confirmed for this href, so
|
||||
# these are read-only, unlike REFRIGERATION's switches.
|
||||
REFRIGERATION_FALLBACK = Capability(
|
||||
href='/refrigeration/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
BinarySensorDesc(key='defrost_active', field='defrost',
|
||||
name='Defrost active', icon='mdi:snowflake-melt',
|
||||
entity_category='diagnostic',
|
||||
value_fn=lambda v: bool(v),
|
||||
exists_fn=lambda rep, resources: '/defrost/block/vs/0' not in resources),
|
||||
BinarySensorDesc(key='rapid_fridge', field='rapidCool',
|
||||
name='Rapid fridge', icon='mdi:fridge-industrial',
|
||||
entity_category='config',
|
||||
value_fn=lambda v: bool(v),
|
||||
exists_fn=lambda rep, resources: '/refrigeration/vs/0' not in resources),
|
||||
BinarySensorDesc(key='rapid_freezing', field='rapidFreeze',
|
||||
name='Rapid freezing', icon='mdi:snowflake',
|
||||
entity_category='config',
|
||||
value_fn=lambda v: bool(v),
|
||||
exists_fn=lambda rep, resources: '/refrigeration/vs/0' not in resources),
|
||||
),
|
||||
)
|
||||
Reference in new issue