Bind microwave built-in vent fan's /hood/fanspeed/vs/0 (issues #137, #142)

Combi microwave units report their vent fan on the same resource shape a
standalone range hood uses, so reuse range_hood.HOOD_FAN directly in the
microwave registry. Unlike a standalone hood, this board has no sibling
/power/0 or /power/vs/0 resource, so LocalThingsRangeHoodFan now falls
back to treating fan speed 0 as the off state when no separate power
resource is present. Also gate HOOD_FAN's automatic_operation sensor on
field presence, since this board doesn't report it.
This commit is contained in:
Marc Billow committed 2026-07-28 00:18:38 +00:00
1 parent c19800ac00
commit e9281aaead
8 files changed
+387 -11

No files matched your search

@@ -7,8 +7,16 @@ Cooking mode, setpoint, cavity power level, and lamp are genuinely
different for this family (different mode vocabulary, different setpoint
bounds, an extra powerLevel field, a differently-named lamp option) and are
defined fresh in capabilities/microwave.py -- see that module's docstring.
Some combi units (built-in over-the-range microwaves, issues #137/#142)
also carry the vent fan's `/hood/fanspeed/vs/0` resource, in the exact same
shape a standalone range hood reports it in -- reused directly from
range_hood.py rather than duplicated. Unlike a standalone hood, this dump
has no sibling `/power/0` or `/power/vs/0` resource; fan.py's
LocalThingsRangeHoodFan falls back to treating fan speed 0 as off in that
case (see its `_has_separate_power` check).
"""
from ..capabilities import common, ignored, microwave, oven
from ..capabilities import common, ignored, microwave, oven, range_hood
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
@@ -24,5 +32,6 @@ REGISTRY = DeviceRegistry(
oven.OVEN_DOOR,
oven.OVEN_CONNECTED,
oven.OVEN_RECIPE_COOK,
range_hood.HOOD_FAN,
]),
)
@@ -99,6 +99,11 @@ HOOD_FAN = Capability(
field='x.com.samsung.da.hood.autoOperation',
icon='mdi:fan-auto',
entity_category='diagnostic',
# Absent on the microwave family's built-in vent fan (issue
# #137) -- this board has no auto-ventilation mode, unlike the
# standalone range hood this capability was written for.
exists_fn=lambda rep, resources: (
not rep or 'x.com.samsung.da.hood.autoOperation' in rep),
value_fn=lambda value: str(value).lower() == 'on',
),
),