feat: extend AC support for TP2X_RAC_20K and TP1X_DA-AC-RAC-01001_0000
Closes the coverage-gap repair for two more room-AC boards (issues #37, - TP2X_RAC_20K reports no oneUiVersion and no '_PRAC_' modelNum token, so its device type went unrecognized -- add a '_RAC_' fallback token to for_device_by_model. - Bind the resources both dumps actually populate: mute-once (switch), display light (switch), self-check (reused from fridge.SELF_CHECK), and the circuit-breaker current-limit setting (read-only diagnostic sensors, since its write contract isn't confirmed from the dump). - Ignore the rest as plumbing/opaque/unconfirmed: control-set descriptor, keepnormalstate flag, software-reset trigger, AI Sleep handshake, absence-monitoring stubs, remote-data-control, remote-temperature, reservation ruleset, and the welcome-temperature tracker. Adds scrubbed fixtures + goldens for both dumps and extends the AC capability/golden-regression tests to assert zero unbound hrefs.
This commit is contained in:
9 files changed
+1162
-12
No files matched your search
@@ -96,4 +96,9 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
# a modelNum carrying the '_PRAC_' (Package Room Air Conditioner) token.
|
||||
if key is None and '_PRAC_' in (model_num or ''):
|
||||
key = 'airconditioner'
|
||||
# Older/simpler RAC boards (e.g. TP2X_RAC_20K, issue #37) use the plain
|
||||
# '_RAC_' token instead -- distinct from '_PRAC_' above (no overlap: the
|
||||
# 'P' sits between the underscore and 'RAC' in that token).
|
||||
if key is None and '_RAC_' in (model_num or ''):
|
||||
key = 'airconditioner'
|
||||
return _REGISTRY_BY_KEY.get(key) if key else None
|
||||
@@ -19,12 +19,15 @@ REGISTRY = DeviceRegistry(
|
||||
common.ALARMS,
|
||||
common.ENERGY_METER,
|
||||
fridge.FIRMWARE_UPDATE,
|
||||
fridge.SELF_CHECK,
|
||||
dishwasher.DIAGNOSIS,
|
||||
airconditioner.CLIMATE,
|
||||
airconditioner.AIR_PURIFY,
|
||||
airconditioner.AUTO_CLEAN,
|
||||
airconditioner.AIR_FILTER,
|
||||
airconditioner.DISPLAY_LIGHT,
|
||||
airconditioner.MUTE_ONCE,
|
||||
airconditioner.CURRENT_LIMIT,
|
||||
*airconditioner.COVERAGE,
|
||||
]),
|
||||
)
|
||||
@@ -15,7 +15,7 @@ different schema (see capabilities/__init__.py). They live only in the AC
|
||||
by_type registry.
|
||||
"""
|
||||
from ..capability import Capability
|
||||
from ..entities import ClimateDesc, SensorDesc, SwitchDesc
|
||||
from ..entities import BinarySensorDesc, ClimateDesc, SensorDesc, SwitchDesc
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Canonical AC resource hrefs. The climate entity (climate.py) binds the
|
||||
@@ -162,6 +162,43 @@ DISPLAY_LIGHT = Capability(
|
||||
),
|
||||
)
|
||||
|
||||
# Confirmed against issue #38's dump (TP1X_DA-AC-RAC-01001_0000): a single
|
||||
# boolean field, no vendor prefix, mirroring the On/Off convention used
|
||||
# throughout the rest of this API.
|
||||
MUTE_ONCE = Capability(
|
||||
href='/option/muteonce/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SwitchDesc(key='mute_once', field='muteonce',
|
||||
name='Mute once', icon='mdi:volume-mute',
|
||||
entity_category='config',
|
||||
value_fn=lambda v: v == 'On',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['option', 'muteonce', 'vs', '0'],
|
||||
{'muteonce': 'On' if p == 'On' else 'Off'})),
|
||||
),
|
||||
)
|
||||
|
||||
# Circuit-breaker current-limit setting (issue #38, TP1X board): `operation`
|
||||
# toggles the limiter and `modes` picks a level out of `supportedModes`
|
||||
# (seen as '3'..'9'). No vendor field-name prefix and no unit/label in the
|
||||
# dump to confirm what the levels mean (amps vs. an abstract tier) --
|
||||
# exposed read-only per the 'don't guess' rule rather than risking an
|
||||
# unverified write to live HVAC hardware.
|
||||
CURRENT_LIMIT = Capability(
|
||||
href='/electriccurrent/vs/0',
|
||||
poll_tier='cold',
|
||||
entities=(
|
||||
BinarySensorDesc(key='current_limit_enabled', field='operation',
|
||||
name='Current limit enabled', icon='mdi:current-ac',
|
||||
entity_category='diagnostic',
|
||||
value_fn=lambda v: v == 'On'),
|
||||
SensorDesc(key='current_limit_level', field='modes',
|
||||
name='Current limit level', icon='mdi:current-ac',
|
||||
entity_category='diagnostic'),
|
||||
),
|
||||
)
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# AC-scoped coverage: the CLIMATE_CONSUMED_HREFS above (read by the climate
|
||||
# entity) plus vendor duplicates / all-zero-ambiguous / plumbing resources.
|
||||
@@ -178,11 +215,12 @@ _AC_IGNORED = [
|
||||
'/humidity/vs/0',
|
||||
# Presence-personalization plumbing (empty item list here).
|
||||
'/personality/presence/vs/0',
|
||||
# --- TP1X-class (oneUiVersion "7.0 Air conditioner") housekeeping / opaque
|
||||
# blobs. These carry no user-actionable state or no documented write
|
||||
# contract, so per the 'don't guess' rule they are ignored rather than
|
||||
# modeled. (Temperature for this class lives at /temperatures/vs/0, now
|
||||
# consumed by the climate entity -- see CLIMATE_CONSUMED_HREFS.)
|
||||
# --- TP1X/TP2X-class housekeeping / opaque blobs. These carry no
|
||||
# user-actionable state or no documented write contract, so per the
|
||||
# 'don't guess' rule they are ignored rather than modeled.
|
||||
# /option/muteonce/vs/0 and /selfcheck/vs/0 are deliberately NOT here --
|
||||
# see MUTE_ONCE and fridge.SELF_CHECK above/in the by_type registry,
|
||||
# both of which have a confirmed, cleanly modelable contract.
|
||||
'/airlevelcheck/vs/0', # periodic air-quality sensing scheduler plumbing
|
||||
'/aisleep/vs/0', # AI-sleep feedback state (no actionable control)
|
||||
'/availablecontrolsets/vs/0', # opaque hex-encoded control-set bitmap
|
||||
@@ -190,11 +228,9 @@ _AC_IGNORED = [
|
||||
'/keepnormalstate/vs/0', # internal keep-normal flag
|
||||
'/mds/absencemonitoring/vs/0', # motion-detection sensor plumbing (empty here)
|
||||
'/mds/absencestate/vs/0', # motion-detection state (empty here)
|
||||
'/option/muteonce/vs/0', # one-shot buzzer mute (no persistent state)
|
||||
'/remotedatacontrol/vs/0', # remote data-control session status
|
||||
'/remotetemperature/vs/0', # external temp-sensor feed (unset on this unit)
|
||||
'/reserverulesets/vs/0', # opaque hex-encoded schedule reservation blob
|
||||
'/selfcheck/vs/0', # self-diagnosis action (start/cancel, no simple state)
|
||||
'/welcome/temperature/vs/0', # welcome-cooling plumbing
|
||||
]
|
||||
|
||||
|
||||
Reference in new issue