feat: extend AC support for TP2X_RAC_20K and TP1X_DA-AC-RAC-01001_0000

Closes the coverage-gap repair for two more room-AC boards (issues #37,

- TP2X_RAC_20K reports no oneUiVersion and no '_PRAC_' modelNum token, so
  its device type went unrecognized -- add a '_RAC_' fallback token to
  for_device_by_model.
- Bind the resources both dumps actually populate: mute-once (switch),
  display light (switch), self-check (reused from fridge.SELF_CHECK), and
  the circuit-breaker current-limit setting (read-only diagnostic sensors,
  since its write contract isn't confirmed from the dump).
- Ignore the rest as plumbing/opaque/unconfirmed: control-set descriptor,
  keepnormalstate flag, software-reset trigger, AI Sleep handshake,
  absence-monitoring stubs, remote-data-control, remote-temperature,
  reservation ruleset, and the welcome-temperature tracker.

Adds scrubbed fixtures + goldens for both dumps and extends the AC
capability/golden-regression tests to assert zero unbound hrefs.
This commit is contained in:
Marc Billow committed 2026-07-22 14:20:55 +00:00
1 parent 4a376a98aa
commit e942c822a6
9 files changed
+1162 -12

No files matched your search

@@ -96,4 +96,9 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
# a modelNum carrying the '_PRAC_' (Package Room Air Conditioner) token.
if key is None and '_PRAC_' in (model_num or ''):
key = 'airconditioner'
# Older/simpler RAC boards (e.g. TP2X_RAC_20K, issue #37) use the plain
# '_RAC_' token instead -- distinct from '_PRAC_' above (no overlap: the
# 'P' sits between the underscore and 'RAC' in that token).
if key is None and '_RAC_' in (model_num or ''):
key = 'airconditioner'
return _REGISTRY_BY_KEY.get(key) if key else None
@@ -19,12 +19,15 @@ REGISTRY = DeviceRegistry(
common.ALARMS,
common.ENERGY_METER,
fridge.FIRMWARE_UPDATE,
fridge.SELF_CHECK,
dishwasher.DIAGNOSIS,
airconditioner.CLIMATE,
airconditioner.AIR_PURIFY,
airconditioner.AUTO_CLEAN,
airconditioner.AIR_FILTER,
airconditioner.DISPLAY_LIGHT,
airconditioner.MUTE_ONCE,
airconditioner.CURRENT_LIMIT,
*airconditioner.COVERAGE,
]),
)
@@ -15,7 +15,7 @@ different schema (see capabilities/__init__.py). They live only in the AC
by_type registry.
"""
from ..capability import Capability
from ..entities import ClimateDesc, SensorDesc, SwitchDesc
from ..entities import BinarySensorDesc, ClimateDesc, SensorDesc, SwitchDesc
# ---------------------------------------------------------------------------
# Canonical AC resource hrefs. The climate entity (climate.py) binds the
@@ -162,6 +162,43 @@ DISPLAY_LIGHT = Capability(
),
)
# Confirmed against issue #38's dump (TP1X_DA-AC-RAC-01001_0000): a single
# boolean field, no vendor prefix, mirroring the On/Off convention used
# throughout the rest of this API.
MUTE_ONCE = Capability(
href='/option/muteonce/vs/0',
poll_tier='warm',
entities=(
SwitchDesc(key='mute_once', field='muteonce',
name='Mute once', icon='mdi:volume-mute',
entity_category='config',
value_fn=lambda v: v == 'On',
write_fn=lambda p, rep, href=None: (
['option', 'muteonce', 'vs', '0'],
{'muteonce': 'On' if p == 'On' else 'Off'})),
),
)
# Circuit-breaker current-limit setting (issue #38, TP1X board): `operation`
# toggles the limiter and `modes` picks a level out of `supportedModes`
# (seen as '3'..'9'). No vendor field-name prefix and no unit/label in the
# dump to confirm what the levels mean (amps vs. an abstract tier) --
# exposed read-only per the 'don't guess' rule rather than risking an
# unverified write to live HVAC hardware.
CURRENT_LIMIT = Capability(
href='/electriccurrent/vs/0',
poll_tier='cold',
entities=(
BinarySensorDesc(key='current_limit_enabled', field='operation',
name='Current limit enabled', icon='mdi:current-ac',
entity_category='diagnostic',
value_fn=lambda v: v == 'On'),
SensorDesc(key='current_limit_level', field='modes',
name='Current limit level', icon='mdi:current-ac',
entity_category='diagnostic'),
),
)
# ---------------------------------------------------------------------------
# AC-scoped coverage: the CLIMATE_CONSUMED_HREFS above (read by the climate
# entity) plus vendor duplicates / all-zero-ambiguous / plumbing resources.
@@ -178,11 +215,12 @@ _AC_IGNORED = [
'/humidity/vs/0',
# Presence-personalization plumbing (empty item list here).
'/personality/presence/vs/0',
# --- TP1X-class (oneUiVersion "7.0 Air conditioner") housekeeping / opaque
# blobs. These carry no user-actionable state or no documented write
# contract, so per the 'don't guess' rule they are ignored rather than
# modeled. (Temperature for this class lives at /temperatures/vs/0, now
# consumed by the climate entity -- see CLIMATE_CONSUMED_HREFS.)
# --- TP1X/TP2X-class housekeeping / opaque blobs. These carry no
# user-actionable state or no documented write contract, so per the
# 'don't guess' rule they are ignored rather than modeled.
# /option/muteonce/vs/0 and /selfcheck/vs/0 are deliberately NOT here --
# see MUTE_ONCE and fridge.SELF_CHECK above/in the by_type registry,
# both of which have a confirmed, cleanly modelable contract.
'/airlevelcheck/vs/0', # periodic air-quality sensing scheduler plumbing
'/aisleep/vs/0', # AI-sleep feedback state (no actionable control)
'/availablecontrolsets/vs/0', # opaque hex-encoded control-set bitmap
@@ -190,11 +228,9 @@ _AC_IGNORED = [
'/keepnormalstate/vs/0', # internal keep-normal flag
'/mds/absencemonitoring/vs/0', # motion-detection sensor plumbing (empty here)
'/mds/absencestate/vs/0', # motion-detection state (empty here)
'/option/muteonce/vs/0', # one-shot buzzer mute (no persistent state)
'/remotedatacontrol/vs/0', # remote data-control session status
'/remotetemperature/vs/0', # external temp-sensor feed (unset on this unit)
'/reserverulesets/vs/0', # opaque hex-encoded schedule reservation blob
'/selfcheck/vs/0', # self-diagnosis action (start/cancel, no simple state)
'/welcome/temperature/vs/0', # welcome-cooling plumbing
]