Type air_monitor's particulates and migrate the recorded statistics
Adding a unit to a sensor that recorded long-term statistics without one is not cosmetic: Home Assistant raises a units_changed repair and then *suppresses statistics generation* for that entity until a human resolves it (sensor/recorder.py's compile path hits `continue`). Shipping the PM device classes on their own would therefore have silently frozen the very history the labels were meant to describe. A v2 -> v3 config-entry migration relabels the statistics metadata first. It rewrites only the metadata row, never the recorded values -- these readings were always µg/m³ and only the label was missing, so nothing needs converting, which is why this uses async_update_statistics_metadata and not change_statistics_unit. It reads entity_ids back off the entity registry rather than rebuilding them from descriptor keys, since a renamed entity's statistic_id no longer follows from its key, and it is scoped by device family: range_hood and airconditioner still declare no unit for their identically-named sensors, so relabelling theirs would create the exact mismatch this exists to prevent. With the migration in place there is no longer a reason to hold the labels back on air_monitor, so it takes them too. That board is one of the two whose fixtures pin the grade bands the mapping rests on -- typing the purifier and not the monitor was an inconsistency, not caution. It still declines the shared state_class column, unchanged. Recorder coupling is guarded: after_dependencies pulls it in when configured, the import is local to the migration, and a setup without it is a no-op. Freshly created entries mint v3 directly, having no history to relabel. Tested at both levels. The unit-level tests patch the recorder and assert which entities are relabelled with which arguments, covering the renamed entity, subdevice-prefixed and instanced keys, the near-miss keys (dustbag_/dustbin_), the skipped families and the recorder-absent path. Because a mock can only prove the call is made, not that it does what the migration needs, a second suite drives a real in-memory recorder end to end: statistics seeded unitless, migration run, metadata confirmed to read µg/m³ / concentration, recorded means confirmed byte-identical, and the units_changed issue confirmed present before and absent after.
This commit is contained in:
8 files changed
+469
-30
No files matched your search
@@ -38,7 +38,9 @@ async def test_migration_recovers_serial_from_unique_id(
|
||||
await hass.config_entries.async_setup(entry.entry_id)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
assert entry.version == 2
|
||||
# Straight through to the current version: v2 -> v3 is a statistics
|
||||
# relabel that no-ops for a family without particulate sensors.
|
||||
assert entry.version == 3
|
||||
assert entry.data[CONF_SERIAL] == MOCK_SERIAL
|
||||
|
||||
|
||||
@@ -257,7 +259,7 @@ async def test_migration_rejects_a_future_entry_version(hass: HomeAssistant) ->
|
||||
written by a newer release."""
|
||||
from custom_components.localthings import async_migrate_entry
|
||||
|
||||
entry = MockConfigEntry(domain=DOMAIN, data=LEGACY_ENTRY_DATA, version=3)
|
||||
entry = MockConfigEntry(domain=DOMAIN, data=LEGACY_ENTRY_DATA, version=4)
|
||||
entry.add_to_hass(hass)
|
||||
|
||||
assert await async_migrate_entry(hass, entry) is False
|
||||
|
||||
Reference in new issue