Merge remote-tracking branch 'origin/main' into claude/device-support-issue-77-freezer
# Conflicts: # custom_components/localthings/registry/by_type/__init__.py # tests/test_by_type.py
This commit is contained in:
28 files changed
+2585
-14
No files matched your search
@@ -3,8 +3,8 @@ from typing import Optional
|
||||
|
||||
from ._base import DeviceRegistry
|
||||
from . import (
|
||||
air_purifier, airconditioner, cooktop, dishwasher, dryer, oven,
|
||||
range as _range, range_hood, refrigerator, washer,
|
||||
air_purifier, airconditioner, cooktop, dehumidifier, dishwasher, dryer,
|
||||
oven, range as _range, range_hood, refrigerator, washer, water_purifier,
|
||||
)
|
||||
|
||||
__all__ = [
|
||||
@@ -19,6 +19,7 @@ _REGISTRY_BY_KEY: dict[str, DeviceRegistry] = {
|
||||
'airconditioner': airconditioner.REGISTRY,
|
||||
'air_conditioner': airconditioner.REGISTRY,
|
||||
'cooktop': cooktop.REGISTRY,
|
||||
'dehumidifier': dehumidifier.REGISTRY,
|
||||
'dishwasher': dishwasher.REGISTRY,
|
||||
'dryer': dryer.REGISTRY,
|
||||
'oven': oven.REGISTRY,
|
||||
@@ -27,6 +28,7 @@ _REGISTRY_BY_KEY: dict[str, DeviceRegistry] = {
|
||||
'range_hood': range_hood.REGISTRY,
|
||||
'refrigerator': refrigerator.REGISTRY,
|
||||
'washer': washer.REGISTRY,
|
||||
'water_purifier': water_purifier.REGISTRY,
|
||||
}
|
||||
|
||||
|
||||
@@ -103,6 +105,26 @@ def _model_num_segments(model_num: str) -> list[str]:
|
||||
return prefix.split('_')
|
||||
|
||||
|
||||
def _consumer_model_key(description: str) -> Optional[str]:
|
||||
"""Registry key from the consumer-model token in `description`, or None.
|
||||
|
||||
Usually that token is the last '_'-delimited segment before any
|
||||
'/board-info' suffix (e.g. '..._WW90DG6U25LEU4' -> 'WW90DG6U25LEU4').
|
||||
But issue #79's dryer pairs two model numbers in one description --
|
||||
'..._DVE50A8800_8600/DC92-...' -- so the true consumer token
|
||||
('DVE50A8800') sits one segment *before* the actual last segment
|
||||
('8600', a bare second model number with no recognizable prefix). Scan
|
||||
segments from the end and take the first one that resolves, rather
|
||||
than assuming the last segment is always it.
|
||||
"""
|
||||
segments = (description or '').split('/', 1)[0].split('_')
|
||||
for segment in reversed(segments):
|
||||
key = _CONSUMER_PREFIX_TO_KEY.get(segment[:2].upper())
|
||||
if key is not None:
|
||||
return key
|
||||
return None
|
||||
|
||||
|
||||
def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegistry]:
|
||||
"""Fallback device-type detection for hardware that never reports
|
||||
oneUiVersion (confirmed for washers -- their /otninformation/vs/0 has
|
||||
@@ -116,8 +138,7 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
DeviceRegistry if the consumer-model code or modelNum resolves to a
|
||||
known type, None otherwise.
|
||||
"""
|
||||
token = (description or '').split('/', 1)[0].rsplit('_', 1)[-1]
|
||||
key = _CONSUMER_PREFIX_TO_KEY.get(token[:2].upper())
|
||||
key = _consumer_model_key(description)
|
||||
if key is None and 'REF' in _model_num_segments(model_num):
|
||||
key = 'refrigerator'
|
||||
# Room air conditioners (e.g. ARTIK051_PRAC_20K) report no oneUiVersion and
|
||||
@@ -138,6 +159,22 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
# resource (see airconditioner.py's _AC_IGNORED).
|
||||
if key is None and '-CAWW-' in (model_num or '').upper():
|
||||
key = 'airconditioner'
|
||||
# Dehumidifiers (e.g. TP1X_DA_AC_DHM_01001_0000, issue #88) share the
|
||||
# DA_AC_ board family with the room-AC models above but carry the
|
||||
# '_DHM_' (DeHuMidifier) token instead of '_RAC_'/'_PRAC_'. Distinct
|
||||
# registry: target humidity, not temperature, is the primary control,
|
||||
# and there's no climate composite.
|
||||
if key is None and '_DHM_' in (model_num or ''):
|
||||
key = 'dehumidifier'
|
||||
# Window air conditioners (e.g. TP1X_DA_AC_WAC_01001_0000, issue #87)
|
||||
# report no oneUiVersion and carry the '_WAC_' (Window Air Conditioner)
|
||||
# token instead of '_RAC_'/'_PRAC_'. Same TP1X-class resource surface
|
||||
# as the room-AC models above (mode/convenient/wind/temperature/power/
|
||||
# filter/humidity all confirmed against the issue #87 dump binding
|
||||
# cleanly against the existing airconditioner registry once routed
|
||||
# here) -- no WAC-specific resources needed.
|
||||
if key is None and '_WAC_' in (model_num or ''):
|
||||
key = 'airconditioner'
|
||||
# Air purifiers (e.g. ARTIK051_TVTL_18K, issue #56) report no
|
||||
# oneUiVersion either, and carry the '_TVTL_' board-family token.
|
||||
if key is None and '_TVTL_' in (model_num or ''):
|
||||
@@ -145,6 +182,10 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
model_identity = f'{model_num} {description}'.upper()
|
||||
if key is None and ('_COOKTOP' in model_identity or '_GB_CT_' in model_identity):
|
||||
key = 'cooktop'
|
||||
# Water purifiers (e.g. TP2X_WATERPURIFIER_20K, issue #90) report no
|
||||
# oneUiVersion and carry the 'WATERPURIFIER' board-family token.
|
||||
if key is None and 'WATERPURIFIER' in model_identity:
|
||||
key = 'water_purifier'
|
||||
if key is None and model_identity.startswith('AHD-'):
|
||||
key = 'range_hood'
|
||||
# Range/cooktop-oven combos (e.g. TP1X_DA-KS-RANGE-0102X, issue #44) --
|
||||
|
||||
@@ -1,11 +1,21 @@
|
||||
"""Cooktop device registry."""
|
||||
"""Gas cooktop device registry (NA9300K-class, PR #23).
|
||||
|
||||
Named 'gas_cooktop' (not 'cooktop') so its diagnostics/device-info label
|
||||
doesn't collide with the unrelated induction_cooktop family (issue #86,
|
||||
by_type/induction_cooktop.py) -- two different OCF surfaces that happen to
|
||||
share the English word "cooktop". The `_REGISTRY_BY_KEY['cooktop']` lookup
|
||||
key is unchanged: it's relied on by real devices reporting
|
||||
oneUiVersion "Cooktop" (for_device), the legacy ARTIK051 modelNum rule
|
||||
(for_device_by_model), and the resource-signature fallback
|
||||
(for_device_by_resources) alike.
|
||||
"""
|
||||
|
||||
from ..capabilities import common, cooktop, ignored
|
||||
from ._base import DeviceRegistry, _build
|
||||
|
||||
|
||||
REGISTRY = DeviceRegistry(
|
||||
name='cooktop',
|
||||
name='gas_cooktop',
|
||||
capabilities=_build([
|
||||
*ignored.IGNORED,
|
||||
cooktop.COOKTOP_POWER,
|
||||
|
||||
@@ -0,0 +1,23 @@
|
||||
"""Dehumidifier device registry (Samsung TP1X_DA_AC_DHM-class, issue #88).
|
||||
|
||||
Shares the DA_AC_ board family with airconditioner.py (power, air filter,
|
||||
auto-clean, mute-once all use the identical resource shapes), so those three
|
||||
Capability objects are reused directly rather than duplicated.
|
||||
"""
|
||||
from ..capabilities import airconditioner, common, dehumidifier, ignored
|
||||
from ._base import DeviceRegistry, _build
|
||||
|
||||
REGISTRY = DeviceRegistry(
|
||||
name='dehumidifier',
|
||||
capabilities=_build([
|
||||
*ignored.IGNORED,
|
||||
*common.UNIVERSAL,
|
||||
*common.POWER,
|
||||
dehumidifier.MODE,
|
||||
dehumidifier.HUMIDITY,
|
||||
airconditioner.AUTO_CLEAN,
|
||||
airconditioner.AIR_FILTER,
|
||||
airconditioner.MUTE_ONCE,
|
||||
*dehumidifier.COVERAGE,
|
||||
]),
|
||||
)
|
||||
@@ -0,0 +1,18 @@
|
||||
"""Water-purifier device registry (Samsung TP2X_WATERPURIFIER-class, issue #90).
|
||||
"""
|
||||
from ..capabilities import common, ignored, water_purifier
|
||||
from ._base import DeviceRegistry, _build
|
||||
|
||||
REGISTRY = DeviceRegistry(
|
||||
name='water_purifier',
|
||||
capabilities=_build([
|
||||
*ignored.IGNORED,
|
||||
*common.UNIVERSAL,
|
||||
common.WATER_FILTER,
|
||||
water_purifier.DISPENSE,
|
||||
water_purifier.STATUS,
|
||||
water_purifier.FAVORITE_CAPACITY,
|
||||
water_purifier.LOCK,
|
||||
*water_purifier.COVERAGE,
|
||||
]),
|
||||
)
|
||||
@@ -0,0 +1,85 @@
|
||||
"""Capabilities for the Samsung dehumidifier family (TP1X_DA_AC_DHM-class,
|
||||
issue #88, model AY18CG7500GED).
|
||||
|
||||
Same DA_AC_ board family as the room-AC models in airconditioner.py (shared
|
||||
power/energy/filter/auto-clean/mute-once resource shapes), but target
|
||||
humidity -- not temperature -- is this device's primary control, and there
|
||||
is no climate composite: power, mode, and humidity are exposed as separate
|
||||
entities rather than folded into one card.
|
||||
"""
|
||||
from ..capability import Capability
|
||||
from ..entities import NumberDesc, SelectDesc, SensorDesc
|
||||
from .common import int_or_none
|
||||
|
||||
|
||||
def _first_mode(rep):
|
||||
"""Representative scalar for the operating-mode select. `modes` is a
|
||||
single-element list on every dump seen so far, mirroring
|
||||
airconditioner._first_mode's handling of the same field shape."""
|
||||
modes = rep.get('x.com.samsung.da.modes')
|
||||
if isinstance(modes, (list, tuple)):
|
||||
return modes[0] if modes else None
|
||||
return modes
|
||||
|
||||
|
||||
MODE = Capability(
|
||||
href='/mode/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SelectDesc(key='operating_mode', rep_fn=_first_mode,
|
||||
icon='mdi:tune-variant',
|
||||
options_field='x.com.samsung.da.supportedModes',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['mode', 'vs', '0'], {'x.com.samsung.da.modes': [p]})),
|
||||
),
|
||||
)
|
||||
|
||||
# Target humidity is this device's primary control (the issue-#88 dump's
|
||||
# equivalent of a thermostat setpoint). No min/max range field is present in
|
||||
# any dump seen so far -- native_min/native_max are deliberately left unset
|
||||
# so the number entity falls back to HA's own 0-100 default, the natural
|
||||
# bound for a percentage field, rather than a bound guessed from one unit's
|
||||
# spec sheet (see the adding-device-support skill's "never hard-code the one
|
||||
# dump's values" section). Step comes live from the device's own `increment`
|
||||
# field.
|
||||
HUMIDITY = Capability(
|
||||
href='/humidity/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SensorDesc(key='humidity', field='x.com.samsung.da.humidity',
|
||||
device_class='humidity', unit='%', state_class='measurement',
|
||||
value_fn=int_or_none),
|
||||
NumberDesc(key='target_humidity', field='x.com.samsung.da.desiredHumidity',
|
||||
device_class='humidity', unit='%',
|
||||
icon='mdi:water-percent',
|
||||
entity_category='config',
|
||||
value_fn=int_or_none,
|
||||
step_fn=lambda rep: int_or_none(rep.get('increment')) or 1,
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['humidity', 'vs', '0'],
|
||||
{'x.com.samsung.da.desiredHumidity': str(int(round(float(p))))})),
|
||||
),
|
||||
)
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Dehumidifier-scoped coverage: vendor plumbing with no user-actionable state
|
||||
# or no documented write contract, following the same 'don't guess' rule as
|
||||
# airconditioner._AC_IGNORED (this is the same DA_AC_ board family). Not in
|
||||
# the global ignored.IGNORED since some of these hrefs collide with other
|
||||
# families' schemas.
|
||||
# ---------------------------------------------------------------------------
|
||||
_DHM_IGNORED = [
|
||||
'/availablecontrolsets/vs/0', # opaque hex-encoded control-set bitmap (id: DHM)
|
||||
'/da/softreset/vs/0', # soft-reset trigger plumbing
|
||||
'/keepnormalstate/vs/0', # internal keep-normal flag
|
||||
'/personality/presence/vs/0', # presence-personalization plumbing (empty item value)
|
||||
'/reserverulesets/vs/0', # opaque hex-encoded schedule reservation blob
|
||||
'/sensors/vs/0', # empty {} on this dump
|
||||
'/welcome/humidity/vs/0', # welcome-mode plumbing (requestId/operatingStatus, inert)
|
||||
# Only supportedModes ([Off, Sleep]) is present -- no live "current
|
||||
# value" field on this dump to confirm the read/write contract, so per
|
||||
# the 'don't guess' rule this is left unmodeled rather than assumed.
|
||||
'/mode/convenient/vs/0',
|
||||
]
|
||||
|
||||
COVERAGE = [Capability(href=h) for h in _DHM_IGNORED]
|
||||
@@ -42,7 +42,10 @@ DRYER_SETTINGS = Capability(
|
||||
# under entity.select.dryer_cycle (Table_03, DV5000-class, captured
|
||||
# 2026-05-29). Codes 0x21 and 0x4C appear in the issue #14 DV90BB5245AES1
|
||||
# editCourseList but aren't identified yet -- they render as the raw code
|
||||
# until named. The /st/dryercourse/vs/0 resource re-encodes the same selected
|
||||
# until named. Codes '01' Normal and '06' Time dry were confirmed on a
|
||||
# DVE50A8600V/A3 (also Table_03) by selecting each cycle on the physical
|
||||
# appliance and reading back the raw code from the entity's state (issue
|
||||
# #80). The /st/dryercourse/vs/0 resource re-encodes the same selected
|
||||
# course and is ignored (ignored.py) -- the mirror of how /st/washercourse/vs/0
|
||||
# is ignored for washers.
|
||||
DRYER_COURSE = Capability(
|
||||
|
||||
@@ -45,6 +45,14 @@ from .laundry import (
|
||||
# (issue #22). Combo units carry their own course set, so these codes
|
||||
# don't imply anything about '1F' on a plain washer.
|
||||
#
|
||||
# Three more -- '52' Eco Cold, '54' Towels, '60' Self Clean+ -- came from a
|
||||
# WF50A8600AV/US, verified directly rather than by inference: the reporter
|
||||
# selected each cycle on the physical appliance and read back the resulting
|
||||
# raw code from the cycle_select entity's state (issue #80). '54' shares a
|
||||
# display name with the existing '24' Towels -- a different code on a
|
||||
# different course table legitimately landing on the same label, not a typo
|
||||
# (same pattern as '21'/'65' Colors and '27'/'5E' Rinse+Spin above).
|
||||
#
|
||||
# No static fallback list of those codes is kept here, deliberately: other
|
||||
# washer models have a different actual course set (a second dump's active
|
||||
# course, '65', isn't even in the list above; models with 'AI Wash'/'Mixed
|
||||
|
||||
@@ -0,0 +1,165 @@
|
||||
"""Capabilities for the Samsung water-purifier family (TP2X_WATERPURIFIER-class,
|
||||
issue #90, model TP2X_WATERPURIFIER_20K).
|
||||
|
||||
Resources verified against the issue #90 diagnostics dump.
|
||||
"""
|
||||
from datetime import datetime, timezone
|
||||
|
||||
from ..capability import Capability
|
||||
from ..entities import BinarySensorDesc, NumberDesc, SelectDesc, SensorDesc, SwitchDesc
|
||||
from .common import int_or_none
|
||||
|
||||
|
||||
def _parse_iso_utc(raw):
|
||||
"""Bare ISO datetime with no timezone field alongside it -- treated as
|
||||
UTC, matching this integration's convention for other bare ISO datetime
|
||||
fields (see washer.py's drum-clean-log comment)."""
|
||||
if not raw:
|
||||
return None
|
||||
try:
|
||||
return datetime.fromisoformat(raw).replace(tzinfo=timezone.utc)
|
||||
except ValueError:
|
||||
return None
|
||||
|
||||
|
||||
DISPENSE = Capability(
|
||||
href='/setting/waterpurifier/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SelectDesc(key='dispense_type', field='x.com.samsung.da.desiredType',
|
||||
icon='mdi:cup-water',
|
||||
options_field='x.com.samsung.da.supportedTypes',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['setting', 'waterpurifier', 'vs', '0'],
|
||||
{'x.com.samsung.da.desiredType': p})),
|
||||
# Only a handful of discrete temperatures are selectable (not a
|
||||
# continuous range) -- a select over the live-reported set, not a
|
||||
# number with invented bounds.
|
||||
SelectDesc(key='hot_water_temperature', field='x.com.samsung.da.tempDesiredHotWater',
|
||||
icon='mdi:thermometer',
|
||||
entity_category='config',
|
||||
options_field='x.com.samsung.da.supportedHotTemperatures',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['setting', 'waterpurifier', 'vs', '0'],
|
||||
{'x.com.samsung.da.tempDesiredHotWater': p})),
|
||||
# Bounds and step come live from the device's own
|
||||
# desiredCapacityRange/capacityResolution fields, not a hardcoded
|
||||
# constant -- see the adding-device-support skill's "never hard-code
|
||||
# the one dump's values" section. No unit is set: capacityUnit reads
|
||||
# "C" on this dump, which can't be right for a volume field, so per
|
||||
# the 'don't guess' rule the unit is left unset rather than assumed
|
||||
# to be mL.
|
||||
NumberDesc(key='dispense_capacity', field='x.com.samsung.da.desiredCapacity',
|
||||
icon='mdi:cup-water',
|
||||
value_fn=int_or_none,
|
||||
range_field='x.com.samsung.da.desiredCapacityRange',
|
||||
step_fn=lambda rep: int_or_none(
|
||||
rep.get('x.com.samsung.da.capacityResolution')) or 1,
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['setting', 'waterpurifier', 'vs', '0'],
|
||||
{'x.com.samsung.da.desiredCapacity': str(int(round(float(p))))})),
|
||||
BinarySensorDesc(key='pouring', field='x.com.samsung.da.pourStatus',
|
||||
icon='mdi:cup-water',
|
||||
value_fn=lambda v: v == 'On'),
|
||||
),
|
||||
)
|
||||
|
||||
STATUS = Capability(
|
||||
href='/status/waterpurifier/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SensorDesc(key='waterpurifier_status', field='x.com.samsung.da.status',
|
||||
icon='mdi:water-pump',
|
||||
entity_category='diagnostic'),
|
||||
BinarySensorDesc(key='filter_door_status', field='x.com.samsung.da.filterDoorStatus',
|
||||
device_class='door',
|
||||
entity_category='diagnostic',
|
||||
value_fn=lambda v: v == 'Open'),
|
||||
SensorDesc(key='sterilize_period', field='x.com.samsung.da.sterilizePeriod',
|
||||
icon='mdi:calendar-sync',
|
||||
entity_category='diagnostic'),
|
||||
SensorDesc(key='sterilize_run_time', field='x.com.samsung.da.sterilizeRunTime',
|
||||
icon='mdi:timer-outline',
|
||||
entity_category='diagnostic'),
|
||||
SensorDesc(key='sterilize_last_time', device_class='timestamp',
|
||||
entity_category='diagnostic',
|
||||
rep_fn=lambda rep: _parse_iso_utc(
|
||||
rep.get('x.com.samsung.da.sterilizeLastTime'))),
|
||||
SensorDesc(key='sterilize_plan_time', device_class='timestamp',
|
||||
entity_category='diagnostic',
|
||||
rep_fn=lambda rep: _parse_iso_utc(
|
||||
rep.get('x.com.samsung.da.sterilizePlanTime'))),
|
||||
SensorDesc(key='filter_clean_remain_time', field='x.com.samsung.da.filterCleanRemainTime',
|
||||
icon='mdi:timer-sand',
|
||||
entity_category='diagnostic'),
|
||||
),
|
||||
)
|
||||
|
||||
FAVORITE_CAPACITY = Capability(
|
||||
href='/favorite/capacity/vs/0',
|
||||
poll_tier='cold',
|
||||
entities=(
|
||||
SwitchDesc(key='favorite_capacity_enabled', field='x.com.samsung.da.switchCapacity',
|
||||
icon='mdi:star-outline',
|
||||
entity_category='config',
|
||||
value_fn=lambda v: v == 'On',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['favorite', 'capacity', 'vs', '0'],
|
||||
{'x.com.samsung.da.switchCapacity': 'On' if p == 'On' else 'Off'})),
|
||||
SelectDesc(key='favorite_capacity', field='x.com.samsung.da.defaultCapacity',
|
||||
icon='mdi:cup-water',
|
||||
entity_category='config',
|
||||
options_field='x.com.samsung.da.capacityList',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['favorite', 'capacity', 'vs', '0'],
|
||||
{'x.com.samsung.da.defaultCapacity': p})),
|
||||
),
|
||||
)
|
||||
|
||||
LOCK = Capability(
|
||||
href='/status/lock/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SwitchDesc(key='hotwater_lock', field='x.com.samsung.da.hotwaterLock',
|
||||
device_class='lock',
|
||||
entity_category='config',
|
||||
value_fn=lambda v: v != 'Unlocked',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['status', 'lock', 'vs', '0'],
|
||||
{'x.com.samsung.da.hotwaterLock': 'Locked' if p == 'On' else 'Unlocked'})),
|
||||
SwitchDesc(key='coldwater_lock', field='x.com.samsung.da.coldwaterLock',
|
||||
device_class='lock',
|
||||
entity_category='config',
|
||||
value_fn=lambda v: v != 'Unlocked',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['status', 'lock', 'vs', '0'],
|
||||
{'x.com.samsung.da.coldwaterLock': 'Locked' if p == 'On' else 'Unlocked'})),
|
||||
SwitchDesc(key='buzz_lock', field='x.com.samsung.da.buzzLock',
|
||||
device_class='lock',
|
||||
entity_category='config',
|
||||
value_fn=lambda v: v != 'Unlocked',
|
||||
write_fn=lambda p, rep, href=None: (
|
||||
['status', 'lock', 'vs', '0'],
|
||||
{'x.com.samsung.da.buzzLock': 'Locked' if p == 'On' else 'Unlocked'})),
|
||||
),
|
||||
)
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Water-purifier-scoped coverage: hrefs with no user-actionable state or no
|
||||
# confirmed contract, following the 'don't guess' rule.
|
||||
# ---------------------------------------------------------------------------
|
||||
_WP_IGNORED = [
|
||||
# supportedModes carries a single opaque wizard-workflow token
|
||||
# ('HOMECARE_WIZARD_V2') and modes reports a completely different,
|
||||
# unrelated value ('WATERFILTER_DISABLE') not even present in
|
||||
# supportedModes -- internal plumbing, not a real user-facing mode
|
||||
# select. OCF-standard /mode/0 mirrors the same vendor resource but is
|
||||
# already covered by the global ignored.IGNORED (fridge's OCF-native
|
||||
# vacation-mode flag shares that href).
|
||||
'/mode/vs/0',
|
||||
# Static support-flags blob (automation.supported.modes/options) -- no
|
||||
# live "current automation setting" field to expose.
|
||||
'/automation/waterpurifier/vs/0',
|
||||
]
|
||||
|
||||
COVERAGE = [Capability(href=h) for h in _WP_IGNORED]
|
||||
Reference in new issue
Block a user