@@ -212,6 +212,14 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
key = 'airconditioner'
|
||||
# Air purifiers (e.g. ARTIK051_TVTL_18K, issue #56) report no
|
||||
# oneUiVersion either, and carry the '_TVTL_' board-family token.
|
||||
# Room air conditioners on the ARTIK051 board (e.g. ARTIK051_KRAC_18K,
|
||||
# issue #136) report no oneUiVersion and carry a '_KRAC_' token. The '_RAC_'
|
||||
# check above cannot see it -- the 'K' sits between the underscore and 'RAC' --
|
||||
# and the consumer-prefix fallback only covers washers/dryers/dishwashers, so
|
||||
# these units fell back to 'unknown' and exposed nothing but power. Same
|
||||
# ARTIK051 board family as the '_TVTL_' air purifier below.
|
||||
if key is None and '_KRAC_' in (model_num or ''):
|
||||
key = 'airconditioner'
|
||||
if key is None and '_TVTL_' in (model_num or ''):
|
||||
key = 'air_purifier'
|
||||
model_identity = f'{model_num} {description}'.upper()
|
||||
|
||||
@@ -15,7 +15,9 @@ different schema (see capabilities/__init__.py). They live only in the AC
|
||||
by_type registry.
|
||||
"""
|
||||
from ..capability import Capability
|
||||
from ..entities import BinarySensorDesc, ClimateDesc, SensorDesc, SwitchDesc
|
||||
from ..entities import (
|
||||
BinarySensorDesc, ClimateDesc, NumberDesc, SensorDesc, SwitchDesc,
|
||||
)
|
||||
from .common import filter_usage_percent, normalize_temp_unit
|
||||
from .laundry import option_write
|
||||
|
||||
@@ -43,11 +45,18 @@ HREF_WIND_DIRECTION = '/wind/direction/vs/0' # swing_mode
|
||||
HREF_WIND_OSCILLATION = '/wind/oscillation/vs/0' # swing_mode fallback
|
||||
HREF_CONVENIENT = '/mode/convenient/vs/0' # preset_mode
|
||||
HREF_TEMPS_VS = '/temperatures/vs/0' # vendor temp fallback (items[] array)
|
||||
# Legacy ARTIK051 boards (ARTIK051_KRAC_18K, issue #136) carry no /wind/* resources
|
||||
# at all: fan speed and vane direction sit together in this one resource, as
|
||||
# x.com.samsung.da.speedLevel (the same 0-4 scale as _DEVICE_TO_FAN) and
|
||||
# x.com.samsung.da.direction (the same codes as _DEVICE_TO_SWING). Their
|
||||
# convenient-mode preset is a Comode_* token in /mode/vs/0's options instead of a
|
||||
# resource of its own -- see climate.py's _legacy_airflow/_legacy_convenient.
|
||||
HREF_AIRFLOW = '/airflow/vs/0' # legacy fan_mode + swing_mode
|
||||
|
||||
CLIMATE_CONSUMED_HREFS = [
|
||||
HREF_POWER, HREF_POWER_VS, HREF_TEMP_CURRENT, HREF_TEMP_DESIRED,
|
||||
HREF_TEMP_CONTROL, HREF_TEMPS_VS, HREF_WIND_STRENGTH, HREF_WIND_DIRECTION,
|
||||
HREF_WIND_OSCILLATION, HREF_CONVENIENT,
|
||||
HREF_WIND_OSCILLATION, HREF_CONVENIENT, HREF_AIRFLOW,
|
||||
]
|
||||
|
||||
|
||||
@@ -127,6 +136,91 @@ def _display_light_write(payload, rep, href=None):
|
||||
{'x.com.samsung.da.options': option_write('Light', token)})
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Legacy ARTIK051 boards keep several settings that newer boards expose as their
|
||||
# own resources (/option/*, /electriccurrent/vs/0, ...) as `<Prefix>_<value>`
|
||||
# tokens inside /mode/vs/0's options blob instead. Reads pull the token apart;
|
||||
# writes reuse option_write's single-token merge, exactly like the display light.
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
def _option_token(rep, prefix):
|
||||
"""Value part of a `<prefix>_<value>` token in /mode/vs/0's options."""
|
||||
for option in _mode_options(rep):
|
||||
if isinstance(option, str) and option.startswith(prefix + '_'):
|
||||
return option.split('_', 1)[1]
|
||||
return None
|
||||
|
||||
|
||||
def _is_legacy_board(resources):
|
||||
"""True for the board generation whose airflow lives in /airflow/vs/0.
|
||||
|
||||
Newer families carry several of the same option tokens (Volume, Sleep,
|
||||
OutdoorTemp, Autoclean) *alongside* dedicated resources for those settings,
|
||||
so an ungated token entity would either duplicate an existing one or apply a
|
||||
scale calibrated elsewhere. Every AC dump on record has one shape or the
|
||||
other: /airflow/vs/0 with no /wind/* at all, or /wind/strength/vs/0 with no
|
||||
/airflow/vs/0. Same test as climate.py's _legacy_airflow(), so the entities
|
||||
below and the climate entity can never disagree about the generation.
|
||||
"""
|
||||
return ('/airflow/vs/0' in resources
|
||||
and '/wind/strength/vs/0' not in resources)
|
||||
|
||||
|
||||
def _has_option_token(prefix):
|
||||
return lambda rep, resources: (
|
||||
_is_legacy_board(resources) and _option_token(rep, prefix) is not None)
|
||||
|
||||
|
||||
def _option_token_on(prefix):
|
||||
return lambda rep: _option_token(rep, prefix) == 'On'
|
||||
|
||||
|
||||
def _option_token_num(prefix, offset=0, divisor=1):
|
||||
def read(rep):
|
||||
raw = _option_token(rep, prefix)
|
||||
try:
|
||||
return (float(raw) - offset) / divisor
|
||||
except (TypeError, ValueError):
|
||||
return None
|
||||
return read
|
||||
|
||||
|
||||
def _option_switch_write(prefix):
|
||||
def write(payload, rep, href=None):
|
||||
return (['mode', 'vs', '0'],
|
||||
{'x.com.samsung.da.options': option_write(prefix, payload)})
|
||||
return write
|
||||
|
||||
|
||||
def _option_number_write(prefix):
|
||||
def write(payload, rep, href=None):
|
||||
return (['mode', 'vs', '0'],
|
||||
{'x.com.samsung.da.options':
|
||||
option_write(prefix, str(int(round(float(payload)))))})
|
||||
return write
|
||||
|
||||
|
||||
def _humidity(rep):
|
||||
"""Relative humidity, preferring the 5%-rounded field where it exists.
|
||||
|
||||
ARTIK051 boards have no fivepercentHumidity field at all and report the
|
||||
plain x.com.samsung.da.humidity instead -- and only populate it while the
|
||||
Air monitoring option is on: the unit measures for roughly half a minute
|
||||
(51% observed, matching what the same unit's cloud integration reported at
|
||||
that moment), then zeroes the field and switches Air monitoring back off by
|
||||
itself. So 0 reads as "not measuring" and is reported as unknown rather than
|
||||
as 0% humidity, which would poison long-term history -- which is also why
|
||||
the boards that do have fivepercentHumidity read a permanent 0 here.
|
||||
"""
|
||||
for field in ('x.com.samsung.da.fivepercentHumidity',
|
||||
'x.com.samsung.da.humidity'):
|
||||
if field in rep:
|
||||
value = _num(rep[field])
|
||||
return value if value else None
|
||||
return None
|
||||
|
||||
|
||||
def _climate_write(payload, rep, href=None):
|
||||
"""Map a (kind, value) command from the climate platform to the
|
||||
(path_segs, body) for that one sub-write. `value` is already the raw device
|
||||
@@ -180,6 +274,16 @@ def _climate_write(payload, rep, href=None):
|
||||
'vertical': 'Swing' if value in ('vertical', 'both') else 'Fix',
|
||||
'horizontal': 'Swing' if value in ('horizontal', 'both') else 'Fix',
|
||||
})
|
||||
if kind == 'fan_legacy':
|
||||
return (['airflow', 'vs', '0'],
|
||||
{'x.com.samsung.da.speedLevel': str(value)})
|
||||
if kind == 'swing_legacy':
|
||||
return (['airflow', 'vs', '0'],
|
||||
{'x.com.samsung.da.direction': value})
|
||||
if kind == 'preset_legacy':
|
||||
# Single-token options merge, same mechanism as _display_light_write.
|
||||
return (['mode', 'vs', '0'],
|
||||
{'x.com.samsung.da.options': option_write('Comode', value)})
|
||||
if kind == 'preset':
|
||||
return (['mode', 'convenient', 'vs', '0'], {'x.com.samsung.da.modes': value})
|
||||
return None
|
||||
@@ -204,6 +308,58 @@ CLIMATE = Capability(
|
||||
exists_fn=_has_display_light_option,
|
||||
write_fn=_display_light_write,
|
||||
icon='mdi:led-on', entity_category='config'),
|
||||
# Settings that this board generation keeps as options[] tokens.
|
||||
SwitchDesc(key='spi', rep_fn=_option_token_on('Spi'),
|
||||
exists_fn=_has_option_token('Spi'),
|
||||
write_fn=_option_switch_write('Spi'),
|
||||
icon='mdi:air-purifier', entity_category='config'),
|
||||
# Shares AUTO_CLEAN's catalog entry rather than duplicating it: same
|
||||
# feature, different board generation (that one is a /option/autoclean/
|
||||
# vs/0 field, absent here). Distinct key, so nothing collides if some
|
||||
# future board ever reported both.
|
||||
SwitchDesc(key='auto_clean_legacy', translation_key='auto_clean',
|
||||
rep_fn=_option_token_on('Autoclean'),
|
||||
exists_fn=_has_option_token('Autoclean'),
|
||||
write_fn=_option_switch_write('Autoclean'),
|
||||
icon='mdi:fan-auto', entity_category='config'),
|
||||
SwitchDesc(key='air_monitoring', rep_fn=_option_token_on('AirMonitoring'),
|
||||
exists_fn=_has_option_token('AirMonitoring'),
|
||||
write_fn=_option_switch_write('AirMonitoring'),
|
||||
icon='mdi:air-filter', entity_category='config'),
|
||||
NumberDesc(key='buzzer_volume', rep_fn=_option_token_num('Volume'),
|
||||
exists_fn=_has_option_token('Volume'),
|
||||
write_fn=_option_number_write('Volume'),
|
||||
native_min=0, native_max=100, step=10,
|
||||
icon='mdi:volume-high', entity_category='config'),
|
||||
# "Good Sleep" timer. 0 = off; the upper bound is a guess (the token
|
||||
# carries no range hint and only 0 has been observed on hardware), so a
|
||||
# write above 0 is unverified.
|
||||
NumberDesc(key='good_sleep', rep_fn=_option_token_num('Sleep'),
|
||||
exists_fn=_has_option_token('Sleep'),
|
||||
write_fn=_option_number_write('Sleep'),
|
||||
native_min=0, native_max=12, step=1, unit='h',
|
||||
icon='mdi:sleep', entity_category='config'),
|
||||
# Outdoor temperature, offset by 55. Two calibration points on one unit:
|
||||
# token 75 while an independent outdoor thermometer in the same install
|
||||
# read 20.3 C, and token 74 against a 19.4 C forecast. Fahrenheit fits far
|
||||
# worse (74 F = 23.3 C); the issue #136 unit's 81 gives 26 C in a warmer
|
||||
# climate, which is also plausible.
|
||||
SensorDesc(key='outdoor_temperature',
|
||||
rep_fn=_option_token_num('OutdoorTemp', offset=55),
|
||||
exists_fn=_has_option_token('OutdoorTemp'),
|
||||
device_class='temperature', state_class='measurement',
|
||||
unit='°C', icon='mdi:home-thermometer-outline'),
|
||||
# Filter time in tenths of an hour: the token read 1710 while the official
|
||||
# Samsung app displayed "171 hours 0 minutes" for the filter on the same
|
||||
# unit, and the .0 matching the app's "0 minutes" pins the scale. Whether
|
||||
# it counts up or down is NOT established -- it was seen rising (171.0 ->
|
||||
# 171.5) while the unit ran, which contradicts the app's "remaining"
|
||||
# wording, so the entity is deliberately named neutrally.
|
||||
SensorDesc(key='filter_time',
|
||||
rep_fn=_option_token_num('FilterTime', divisor=10),
|
||||
exists_fn=_has_option_token('FilterTime'),
|
||||
device_class='duration', unit='h',
|
||||
state_class='measurement', icon='mdi:air-filter'),
|
||||
),
|
||||
)
|
||||
|
||||
@@ -357,15 +513,23 @@ CURRENT_TEMPERATURE_VS = Capability(
|
||||
# Only the vendor resource's `fivepercentHumidity` (current reading, rounded
|
||||
# to the nearest 5%) has live data on the issue #75 dump -- its `humidity`
|
||||
# field, and the OCF-standard /humidity/0 resource entirely, both read a
|
||||
# stuck "0" there and stay ignored per the 'don't guess' rule (see
|
||||
# _AC_IGNORED below).
|
||||
# stuck "0" there, so /humidity/0 stays ignored per the 'don't guess' rule
|
||||
# (see _AC_IGNORED below).
|
||||
#
|
||||
# ARTIK051 boards (issue #136) have no fivepercentHumidity field at all, and
|
||||
# there the plain `humidity` field is not stuck: it carries a real reading
|
||||
# (51%, matching the same unit's cloud integration at that moment) for as long
|
||||
# as the Air monitoring option is on, which the unit itself switches back off
|
||||
# after roughly a minute -- so most dumps catch it at 0. Hence _humidity's
|
||||
# fallback, and hence 0 reading as "not measuring" rather than 0%: on both
|
||||
# board generations a zero here means no measurement, never dry air.
|
||||
# /humidity/0 stayed 0 throughout that same observation too.
|
||||
HUMIDITY = Capability(
|
||||
href='/humidity/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SensorDesc(key='humidity', field='x.com.samsung.da.fivepercentHumidity',
|
||||
device_class='humidity', state_class='measurement', unit='%',
|
||||
value_fn=_num),
|
||||
SensorDesc(key='humidity', rep_fn=_humidity,
|
||||
device_class='humidity', state_class='measurement', unit='%'),
|
||||
),
|
||||
)
|
||||
|
||||
@@ -397,6 +561,12 @@ _AC_IGNORED = [
|
||||
'/humidity/0',
|
||||
# Presence-personalization plumbing (empty item list here).
|
||||
'/personality/presence/vs/0',
|
||||
# OCF-standard mirror of /airflow/vs/0 ({speed, direction} vs
|
||||
# {speedLevel, direction}, identical values). The climate entity reads and
|
||||
# writes the vendor form, which is the one confirmed on hardware here --
|
||||
# note that air_purifier.py found the opposite ordering on its family, so
|
||||
# neither form is reliable sight-unseen and this one stays unmodeled.
|
||||
'/airflow/0',
|
||||
# --- TP1X/TP2X-class housekeeping / opaque blobs. These carry no
|
||||
# user-actionable state or no documented write contract, so per the
|
||||
# 'don't guess' rule they are ignored rather than modeled.
|
||||
|
||||
Reference in new issue