Merge pull request #146 from perseus177/artik051-krac-legacy-ac

Support ARTIK051_KRAC_18K air conditioners (issue #136)
This commit is contained in:
Marc Billow authored and GitHub committed 2026-07-28 08:00:48 -05:00
commit f5be651430
10 files changed
+805 -12

No files matched your search

@@ -212,6 +212,14 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
key = 'airconditioner'
# Air purifiers (e.g. ARTIK051_TVTL_18K, issue #56) report no
# oneUiVersion either, and carry the '_TVTL_' board-family token.
# Room air conditioners on the ARTIK051 board (e.g. ARTIK051_KRAC_18K,
# issue #136) report no oneUiVersion and carry a '_KRAC_' token. The '_RAC_'
# check above cannot see it -- the 'K' sits between the underscore and 'RAC' --
# and the consumer-prefix fallback only covers washers/dryers/dishwashers, so
# these units fell back to 'unknown' and exposed nothing but power. Same
# ARTIK051 board family as the '_TVTL_' air purifier below.
if key is None and '_KRAC_' in (model_num or ''):
key = 'airconditioner'
if key is None and '_TVTL_' in (model_num or ''):
key = 'air_purifier'
model_identity = f'{model_num} {description}'.upper()
@@ -15,7 +15,9 @@ different schema (see capabilities/__init__.py). They live only in the AC
by_type registry.
"""
from ..capability import Capability
from ..entities import BinarySensorDesc, ClimateDesc, SensorDesc, SwitchDesc
from ..entities import (
BinarySensorDesc, ClimateDesc, NumberDesc, SensorDesc, SwitchDesc,
)
from .common import filter_usage_percent, normalize_temp_unit
from .laundry import option_write
@@ -43,11 +45,18 @@ HREF_WIND_DIRECTION = '/wind/direction/vs/0' # swing_mode
HREF_WIND_OSCILLATION = '/wind/oscillation/vs/0' # swing_mode fallback
HREF_CONVENIENT = '/mode/convenient/vs/0' # preset_mode
HREF_TEMPS_VS = '/temperatures/vs/0' # vendor temp fallback (items[] array)
# Legacy ARTIK051 boards (ARTIK051_KRAC_18K, issue #136) carry no /wind/* resources
# at all: fan speed and vane direction sit together in this one resource, as
# x.com.samsung.da.speedLevel (the same 0-4 scale as _DEVICE_TO_FAN) and
# x.com.samsung.da.direction (the same codes as _DEVICE_TO_SWING). Their
# convenient-mode preset is a Comode_* token in /mode/vs/0's options instead of a
# resource of its own -- see climate.py's _legacy_airflow/_legacy_convenient.
HREF_AIRFLOW = '/airflow/vs/0' # legacy fan_mode + swing_mode
CLIMATE_CONSUMED_HREFS = [
HREF_POWER, HREF_POWER_VS, HREF_TEMP_CURRENT, HREF_TEMP_DESIRED,
HREF_TEMP_CONTROL, HREF_TEMPS_VS, HREF_WIND_STRENGTH, HREF_WIND_DIRECTION,
HREF_WIND_OSCILLATION, HREF_CONVENIENT,
HREF_WIND_OSCILLATION, HREF_CONVENIENT, HREF_AIRFLOW,
]
@@ -127,6 +136,91 @@ def _display_light_write(payload, rep, href=None):
{'x.com.samsung.da.options': option_write('Light', token)})
# ---------------------------------------------------------------------------
# Legacy ARTIK051 boards keep several settings that newer boards expose as their
# own resources (/option/*, /electriccurrent/vs/0, ...) as `<Prefix>_<value>`
# tokens inside /mode/vs/0's options blob instead. Reads pull the token apart;
# writes reuse option_write's single-token merge, exactly like the display light.
# ---------------------------------------------------------------------------
def _option_token(rep, prefix):
"""Value part of a `<prefix>_<value>` token in /mode/vs/0's options."""
for option in _mode_options(rep):
if isinstance(option, str) and option.startswith(prefix + '_'):
return option.split('_', 1)[1]
return None
def _is_legacy_board(resources):
"""True for the board generation whose airflow lives in /airflow/vs/0.
Newer families carry several of the same option tokens (Volume, Sleep,
OutdoorTemp, Autoclean) *alongside* dedicated resources for those settings,
so an ungated token entity would either duplicate an existing one or apply a
scale calibrated elsewhere. Every AC dump on record has one shape or the
other: /airflow/vs/0 with no /wind/* at all, or /wind/strength/vs/0 with no
/airflow/vs/0. Same test as climate.py's _legacy_airflow(), so the entities
below and the climate entity can never disagree about the generation.
"""
return ('/airflow/vs/0' in resources
and '/wind/strength/vs/0' not in resources)
def _has_option_token(prefix):
return lambda rep, resources: (
_is_legacy_board(resources) and _option_token(rep, prefix) is not None)
def _option_token_on(prefix):
return lambda rep: _option_token(rep, prefix) == 'On'
def _option_token_num(prefix, offset=0, divisor=1):
def read(rep):
raw = _option_token(rep, prefix)
try:
return (float(raw) - offset) / divisor
except (TypeError, ValueError):
return None
return read
def _option_switch_write(prefix):
def write(payload, rep, href=None):
return (['mode', 'vs', '0'],
{'x.com.samsung.da.options': option_write(prefix, payload)})
return write
def _option_number_write(prefix):
def write(payload, rep, href=None):
return (['mode', 'vs', '0'],
{'x.com.samsung.da.options':
option_write(prefix, str(int(round(float(payload)))))})
return write
def _humidity(rep):
"""Relative humidity, preferring the 5%-rounded field where it exists.
ARTIK051 boards have no fivepercentHumidity field at all and report the
plain x.com.samsung.da.humidity instead -- and only populate it while the
Air monitoring option is on: the unit measures for roughly half a minute
(51% observed, matching what the same unit's cloud integration reported at
that moment), then zeroes the field and switches Air monitoring back off by
itself. So 0 reads as "not measuring" and is reported as unknown rather than
as 0% humidity, which would poison long-term history -- which is also why
the boards that do have fivepercentHumidity read a permanent 0 here.
"""
for field in ('x.com.samsung.da.fivepercentHumidity',
'x.com.samsung.da.humidity'):
if field in rep:
value = _num(rep[field])
return value if value else None
return None
def _climate_write(payload, rep, href=None):
"""Map a (kind, value) command from the climate platform to the
(path_segs, body) for that one sub-write. `value` is already the raw device
@@ -180,6 +274,16 @@ def _climate_write(payload, rep, href=None):
'vertical': 'Swing' if value in ('vertical', 'both') else 'Fix',
'horizontal': 'Swing' if value in ('horizontal', 'both') else 'Fix',
})
if kind == 'fan_legacy':
return (['airflow', 'vs', '0'],
{'x.com.samsung.da.speedLevel': str(value)})
if kind == 'swing_legacy':
return (['airflow', 'vs', '0'],
{'x.com.samsung.da.direction': value})
if kind == 'preset_legacy':
# Single-token options merge, same mechanism as _display_light_write.
return (['mode', 'vs', '0'],
{'x.com.samsung.da.options': option_write('Comode', value)})
if kind == 'preset':
return (['mode', 'convenient', 'vs', '0'], {'x.com.samsung.da.modes': value})
return None
@@ -204,6 +308,58 @@ CLIMATE = Capability(
exists_fn=_has_display_light_option,
write_fn=_display_light_write,
icon='mdi:led-on', entity_category='config'),
# Settings that this board generation keeps as options[] tokens.
SwitchDesc(key='spi', rep_fn=_option_token_on('Spi'),
exists_fn=_has_option_token('Spi'),
write_fn=_option_switch_write('Spi'),
icon='mdi:air-purifier', entity_category='config'),
# Shares AUTO_CLEAN's catalog entry rather than duplicating it: same
# feature, different board generation (that one is a /option/autoclean/
# vs/0 field, absent here). Distinct key, so nothing collides if some
# future board ever reported both.
SwitchDesc(key='auto_clean_legacy', translation_key='auto_clean',
rep_fn=_option_token_on('Autoclean'),
exists_fn=_has_option_token('Autoclean'),
write_fn=_option_switch_write('Autoclean'),
icon='mdi:fan-auto', entity_category='config'),
SwitchDesc(key='air_monitoring', rep_fn=_option_token_on('AirMonitoring'),
exists_fn=_has_option_token('AirMonitoring'),
write_fn=_option_switch_write('AirMonitoring'),
icon='mdi:air-filter', entity_category='config'),
NumberDesc(key='buzzer_volume', rep_fn=_option_token_num('Volume'),
exists_fn=_has_option_token('Volume'),
write_fn=_option_number_write('Volume'),
native_min=0, native_max=100, step=10,
icon='mdi:volume-high', entity_category='config'),
# "Good Sleep" timer. 0 = off; the upper bound is a guess (the token
# carries no range hint and only 0 has been observed on hardware), so a
# write above 0 is unverified.
NumberDesc(key='good_sleep', rep_fn=_option_token_num('Sleep'),
exists_fn=_has_option_token('Sleep'),
write_fn=_option_number_write('Sleep'),
native_min=0, native_max=12, step=1, unit='h',
icon='mdi:sleep', entity_category='config'),
# Outdoor temperature, offset by 55. Two calibration points on one unit:
# token 75 while an independent outdoor thermometer in the same install
# read 20.3 C, and token 74 against a 19.4 C forecast. Fahrenheit fits far
# worse (74 F = 23.3 C); the issue #136 unit's 81 gives 26 C in a warmer
# climate, which is also plausible.
SensorDesc(key='outdoor_temperature',
rep_fn=_option_token_num('OutdoorTemp', offset=55),
exists_fn=_has_option_token('OutdoorTemp'),
device_class='temperature', state_class='measurement',
unit='°C', icon='mdi:home-thermometer-outline'),
# Filter time in tenths of an hour: the token read 1710 while the official
# Samsung app displayed "171 hours 0 minutes" for the filter on the same
# unit, and the .0 matching the app's "0 minutes" pins the scale. Whether
# it counts up or down is NOT established -- it was seen rising (171.0 ->
# 171.5) while the unit ran, which contradicts the app's "remaining"
# wording, so the entity is deliberately named neutrally.
SensorDesc(key='filter_time',
rep_fn=_option_token_num('FilterTime', divisor=10),
exists_fn=_has_option_token('FilterTime'),
device_class='duration', unit='h',
state_class='measurement', icon='mdi:air-filter'),
),
)
@@ -357,15 +513,23 @@ CURRENT_TEMPERATURE_VS = Capability(
# Only the vendor resource's `fivepercentHumidity` (current reading, rounded
# to the nearest 5%) has live data on the issue #75 dump -- its `humidity`
# field, and the OCF-standard /humidity/0 resource entirely, both read a
# stuck "0" there and stay ignored per the 'don't guess' rule (see
# _AC_IGNORED below).
# stuck "0" there, so /humidity/0 stays ignored per the 'don't guess' rule
# (see _AC_IGNORED below).
#
# ARTIK051 boards (issue #136) have no fivepercentHumidity field at all, and
# there the plain `humidity` field is not stuck: it carries a real reading
# (51%, matching the same unit's cloud integration at that moment) for as long
# as the Air monitoring option is on, which the unit itself switches back off
# after roughly a minute -- so most dumps catch it at 0. Hence _humidity's
# fallback, and hence 0 reading as "not measuring" rather than 0%: on both
# board generations a zero here means no measurement, never dry air.
# /humidity/0 stayed 0 throughout that same observation too.
HUMIDITY = Capability(
href='/humidity/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='humidity', field='x.com.samsung.da.fivepercentHumidity',
device_class='humidity', state_class='measurement', unit='%',
value_fn=_num),
SensorDesc(key='humidity', rep_fn=_humidity,
device_class='humidity', state_class='measurement', unit='%'),
),
)
@@ -397,6 +561,12 @@ _AC_IGNORED = [
'/humidity/0',
# Presence-personalization plumbing (empty item list here).
'/personality/presence/vs/0',
# OCF-standard mirror of /airflow/vs/0 ({speed, direction} vs
# {speedLevel, direction}, identical values). The climate entity reads and
# writes the vendor form, which is the one confirmed on hardware here --
# note that air_purifier.py found the opposite ordering on its family, so
# neither form is reliable sight-unseen and this one stays unmodeled.
'/airflow/0',
# --- TP1X/TP2X-class housekeeping / opaque blobs. These carry no
# user-actionable state or no documented write contract, so per the
# 'don't guess' rule they are ignored rather than modeled.