AR10/13/18BYEAAWKNME report no oneUiVersion and no '_RAC_'/'-RAC-' token at all, so for_device_by_model() fell through to 'unknown' and every href went uncovered. The board carries the same TP1X-class resource surface as every other room AC already supported (mode/ convenient/wind/temperature/power/filter/humidity), so this reuses the existing airconditioner registry via a new 'ARA-WW-' modelNum fallback rather than adding a new device type -- confirmed against all four reporters' dumps binding cleanly with zero unbound hrefs.
This commit is contained in:
5 files changed
+536
No files matched your search
@@ -198,6 +198,16 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
# here) -- no WAC-specific resources needed.
|
||||
if key is None and '_WAC_' in (model_num or ''):
|
||||
key = 'airconditioner'
|
||||
# ARA-WW-class wall-mount RACs (e.g. ARA-WW-TP1-22-COMMON, issues #115/
|
||||
# #116/#117/#120) report no oneUiVersion and no '_RAC_'/'-RAC-' token at
|
||||
# all -- the board family is spelled 'ARA-WW-' instead. Same resource
|
||||
# surface as the other TP1X-class room ACs above (mode/convenient/wind/
|
||||
# temperature/power/filter/humidity all confirmed against these dumps
|
||||
# binding cleanly against the existing airconditioner registry once
|
||||
# routed here) -- no ARA-WW-specific resources needed, so this reuses
|
||||
# the same registry rather than adding a new device type.
|
||||
if key is None and 'ARA-WW-' in (model_num or '').upper():
|
||||
key = 'airconditioner'
|
||||
# Air purifiers (e.g. ARTIK051_TVTL_18K, issue #56) report no
|
||||
# oneUiVersion either, and carry the '_TVTL_' board-family token.
|
||||
if key is None and '_TVTL_' in (model_num or ''):
|
||||
|
||||
Reference in new issue