Add cool-only global RAC support: WindFree, Auto mode, display light
Finishes PR #91's contribution (pedroperosin) with the requested review changes applied, on our own branch: - Preset resolution is now fully dynamic, read from each unit's own /mode/convenient/vs/0 supportedModes instead of a static per-model table -- any board's convenient modes (including WindFree's Nano/ NanoSleep) surface without code changes. Unlabelled codes across existing fixtures (longwind, motionindirect, motiondirect, drycomfort) plus the two new WindFree ones are added to en.json/nl.json. - 'Auto' now maps to HVACMode.AUTO instead of HEAT_COOL: these are single-setpoint "device decides" units, not two-setpoint heat+cool ones. 'Fan' is added alongside 'Wind' as a second FAN_ONLY spelling; a new _device_code_for_hvac() picks the code from the unit's own supportedModes since the flat map can't disambiguate two device codes mapping to one HA value. - Detection gains a hyphenated '-RAC-' modelNum fallback (alongside the existing '_RAC_') for cool-only global RAC variants whose /otninformation/vs/0 ships no swVersionInfo block. - Adds a display_light switch sourced from /mode/vs/0's opaque options blob (inverted Light_On/Light_Off token) for boards with no dedicated /light/vs/0 switch. Write-path behavioural change (touches the path iterated on across #9/#17/#27/#38/#54): power now targets the vendor /power/vs/0 instead of the OCF /power/0, and _is_on() reads vendor-first. /power/0 is absent on several known AC boards, so the previous OCF-first read/write pair could report and act on stale state -- consistent with #53's "can turn on but not off". Target temperature now picks its channel (OCF pair vs. vendor items[]) based on which the unit actually reports, reading and writing the same one. The vendor temperature write and the new display-light write both carry only the changed field(s), not the whole resource -- confirmed sufficient on the wire, the device merges the rest itself. That requires the coordinator's optimistic cache to do the same merge on the read side so a setpoint change doesn't blank out current/min/max/unit for the settle window: common.py gains merge_items_field() next to the existing merge_options_field(), and async_send_command wires it in for any write touching x.com.samsung.da.items. New fixture/golden for the cool-only global RAC variant (TP1X_DA-AC-RAC- 01001, AI_RAC_GLOBAL_COOLONLY_3.0); display_light added to the goldens for boards that gain the new options-based switch. Regenerated against current main rather than copied from the original PR, since those goldens had already shifted (current_temperature_c/humidity from issue #75).
This commit is contained in:
19 files changed
+1002
-71
No files matched your search
@@ -160,10 +160,18 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
|
||||
# a modelNum carrying the '_PRAC_' (Package Room Air Conditioner) token.
|
||||
if key is None and '_PRAC_' in (model_num or ''):
|
||||
key = 'airconditioner'
|
||||
# Older/simpler RAC boards (e.g. TP2X_RAC_20K, issue #37) use the plain
|
||||
# '_RAC_' token instead -- distinct from '_PRAC_' above (no overlap: the
|
||||
# 'P' sits between the underscore and 'RAC' in that token).
|
||||
if key is None and '_RAC_' in (model_num or ''):
|
||||
# Other RAC boards carry a bare 'RAC' (Room Air Conditioner) token in the
|
||||
# modelNum, in one of two spellings: the underscore form '_RAC_' (e.g.
|
||||
# TP2X_RAC_20K, issue #37) or the hyphenated form '-RAC-' (e.g.
|
||||
# TP1X_DA-AC-RAC-01001, a cool-only global variant, issue #91). Both are
|
||||
# distinct from '_PRAC_' above ('P' sits before 'RAC' with no delimiter)
|
||||
# and from range ('-RANGE-') / oven ('-OVEN-') tokens. Most TP1X boards
|
||||
# self-report oneUiVersion and resolve via for_device() upstream of this
|
||||
# fallback; the hyphenated match is what rescues variants whose
|
||||
# /otninformation/vs/0 ships no swVersionInfo block at all, so
|
||||
# oneUiVersion is empty.
|
||||
if key is None and ('_RAC_' in (model_num or '')
|
||||
or '-RAC-' in (model_num or '').upper()):
|
||||
key = 'airconditioner'
|
||||
# System air conditioners (multi-indoor-unit commercial installs, e.g.
|
||||
# A-CAWW-TP2-20-COMMON, issue #52) report no oneUiVersion either and
|
||||
|
||||
@@ -17,6 +17,7 @@ by_type registry.
|
||||
from ..capability import Capability
|
||||
from ..entities import BinarySensorDesc, ClimateDesc, SensorDesc, SwitchDesc
|
||||
from .common import normalize_temp_unit
|
||||
from .laundry import option_write
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Canonical AC resource hrefs. The climate entity (climate.py) binds the
|
||||
@@ -91,21 +92,87 @@ def _first_mode(rep):
|
||||
return modes
|
||||
|
||||
|
||||
def _mode_options(rep):
|
||||
opts = rep.get('x.com.samsung.da.options')
|
||||
return opts if isinstance(opts, (list, tuple)) else ()
|
||||
|
||||
|
||||
def _has_display_light_option(rep, resources):
|
||||
"""True when the panel light state is carried inside /mode/vs/0's options
|
||||
blob (a `Light_On`/`Light_Off` token) rather than a dedicated /light/vs/0
|
||||
switch. The two encodings are mutually exclusive across observed boards:
|
||||
models exposing the /light/vs/0 switch (bound by DISPLAY_LIGHT below)
|
||||
carry no Light_* option, so this entity only materialises on the boards
|
||||
that would otherwise have no display-light entity at all."""
|
||||
return any(isinstance(o, str) and o.startswith('Light_')
|
||||
for o in _mode_options(rep))
|
||||
|
||||
|
||||
def _display_light_on(rep):
|
||||
"""Panel display light state from /mode/vs/0's options blob. The token is
|
||||
INVERTED relative to its name -- confirmed by a live toggle test: with the
|
||||
panel lit the option reads `Light_Off`, and with it dark it reads
|
||||
`Light_On` (the flag really encodes "night/display-off mode active"). So
|
||||
`Light_Off` -> light on, `Light_On` -> light off. Read-only from here; the
|
||||
write below uses the device's own single-token merge (see option_write)."""
|
||||
for o in _mode_options(rep):
|
||||
if isinstance(o, str) and o.startswith('Light_'):
|
||||
return o == 'Light_Off'
|
||||
return None
|
||||
|
||||
|
||||
def _display_light_write(payload, rep, href=None):
|
||||
"""Toggle the panel light via a single-token /mode/vs/0 options write
|
||||
('SingleCommand_1' is advertised in this family's /configuration/vs/0
|
||||
airconOptionList; option_write's one-token merge is the same mechanism
|
||||
air_purifier.py uses for its own Light switch). Polarity is inverted (see
|
||||
_display_light_on): switching the lamp ON writes 'Light_Off', OFF writes
|
||||
'Light_On'."""
|
||||
token = 'Off' if payload == 'On' else 'On'
|
||||
return (['mode', 'vs', '0'],
|
||||
{'x.com.samsung.da.options': option_write('Light', token)})
|
||||
|
||||
|
||||
def _climate_write(payload, rep, href=None):
|
||||
"""Map a (kind, value) command from the climate platform to the
|
||||
(path_segs, body) for that one sub-write. `value` is already the raw device
|
||||
code (the platform maps HA<->device). async_send_command POSTs to path_segs,
|
||||
so a single desc drives writes across power/mode/temperature/wind resources.
|
||||
Read-modify-write safe: each write sends only its own field, leaving the
|
||||
resource's other fields (e.g. /mode/vs/0's opaque `options` blob) untouched.
|
||||
so a single desc drives writes across the power/mode/temperature/wind
|
||||
resources.
|
||||
|
||||
Power goes to the vendor `/power/vs/0` (the OCF `/power/0` is absent on
|
||||
most boards and a non-authoritative mirror where present -- vendor works
|
||||
on every board). Temperature is board-dependent, so the platform picks the
|
||||
channel and sends `temperature_ocf` (-> OCF `/temperature/desired/0`,
|
||||
boards with the full OCF current+desired pair) or `temperature` (-> vendor
|
||||
`/temperatures/vs/0`, boards without it). Mode/fan/swing/preset are always
|
||||
the vendor `/x/vs/0` resources.
|
||||
|
||||
Each write sends only its own field(s), leaving the resource's other
|
||||
fields (e.g. /mode/vs/0's opaque `options` blob, or the vendor temperature
|
||||
item's current/minimum/maximum/unit) untouched -- the device merges the
|
||||
rest itself, same contract as the options[] array (see
|
||||
common.merge_items_field / merge_options_field, which keep the
|
||||
coordinator's optimistic cache complete for the settle window instead of
|
||||
this write echoing those fields back).
|
||||
"""
|
||||
kind, value = payload
|
||||
if kind == 'power':
|
||||
return (['power', '0'], {'value': bool(value)})
|
||||
return (['power', 'vs', '0'],
|
||||
{'x.com.samsung.da.power': 'On' if value else 'Off'})
|
||||
if kind == 'mode':
|
||||
return (['mode', 'vs', '0'], {'x.com.samsung.da.modes': [value]})
|
||||
if kind == 'temperature_ocf':
|
||||
return (['temperature', 'desired', '0'],
|
||||
{'temperature': int(round(float(value)))})
|
||||
if kind == 'temperature':
|
||||
return (['temperature', 'desired', '0'], {'temperature': int(round(float(value)))})
|
||||
# Vendor items[] array; only one item observed on every AC dump, id
|
||||
# '0'. See the docstring above for why this doesn't echo current/
|
||||
# minimum/maximum/unit back at the unit.
|
||||
return (['temperatures', 'vs', '0'],
|
||||
{'x.com.samsung.da.items': [
|
||||
{'x.com.samsung.da.id': '0',
|
||||
'x.com.samsung.da.desired': str(int(round(float(value))))}]})
|
||||
if kind == 'fan':
|
||||
return (['wind', 'strength', 'vs', '0'], {'x.com.samsung.da.modes': value})
|
||||
if kind == 'swing':
|
||||
@@ -121,6 +188,19 @@ CLIMATE = Capability(
|
||||
entities=(
|
||||
ClimateDesc(key='climate', translation_key='airconditioner',
|
||||
rep_fn=_first_mode, write_fn=_climate_write),
|
||||
# Display (panel) light switch, only on boards that encode it in
|
||||
# /mode/vs/0's options instead of a /light/vs/0 switch (see
|
||||
# _has_display_light_option). Shares the /mode/vs/0 href with the
|
||||
# climate entity above -- same Capability, so no multi-cap
|
||||
# discriminator is needed. /mode/vs/0 is OBSERVE-subscribed, so state
|
||||
# updates on push; writes go through the single-token merge in
|
||||
# _display_light_write. Shares the switch.display_light translation
|
||||
# with DISPLAY_LIGHT (the /light/vs/0 switch on other boards) --
|
||||
# mutually exclusive per href, so only one ever binds for a given unit.
|
||||
SwitchDesc(key='display_light', rep_fn=_display_light_on,
|
||||
exists_fn=_has_display_light_option,
|
||||
write_fn=_display_light_write,
|
||||
icon='mdi:led-on', entity_category='config'),
|
||||
),
|
||||
)
|
||||
|
||||
@@ -304,7 +384,14 @@ _AC_IGNORED = [
|
||||
'/mds/absencemonitoring/vs/0', # motion-detection sensor plumbing (empty here)
|
||||
'/mds/absencestate/vs/0', # motion-detection state (empty here)
|
||||
'/remotedatacontrol/vs/0', # remote data-control session status
|
||||
'/remotedeviceinfo/vs/0', # remote paired-device id list (empty didList here)
|
||||
'/remotetemperature/vs/0', # external temp-sensor feed (unset on this unit)
|
||||
# Manual airflow-step position (supportedModes Off/80/60/40/Power).
|
||||
# Overlaps the /wind/direction swing control already on the climate card,
|
||||
# and the meaning of the numeric steps vs. 'Power' isn't documented in the
|
||||
# dump -- ignored per the 'don't guess' rule rather than modeled as a
|
||||
# select whose write could confuse live HVAC hardware.
|
||||
'/stepcontrol/vs/0',
|
||||
'/reserverulesets/vs/0', # opaque hex-encoded schedule reservation blob
|
||||
'/welcome/temperature/vs/0', # welcome-cooling plumbing
|
||||
# System-AC-only (multi-indoor-unit commercial installs, e.g.
|
||||
|
||||
@@ -104,6 +104,34 @@ def merge_options_field(cached, new_tokens):
|
||||
return merged
|
||||
|
||||
|
||||
def merge_items_field(cached, new_items):
|
||||
"""Merge a partial x.com.samsung.da.items[]-style write (matched by
|
||||
x.com.samsung.da.id) into a cached items array -- the read-side
|
||||
counterpart of merge_options_field above, for the items[] shape instead
|
||||
of the packed options[] shape.
|
||||
|
||||
Confirmed on hardware that a write only needs to carry the array item
|
||||
with the changed id plus the field(s) being changed; the device merges
|
||||
the rest itself (same fact as the options[] case, different array --
|
||||
see airconditioner._climate_write's vendor temperature write). Fields
|
||||
within the matched item are merged, not replaced outright, so a
|
||||
setpoint-only write doesn't wipe current/minimum/maximum/unit from the
|
||||
optimistic cache entry for the settle window. An id with no match in
|
||||
`cached` is appended."""
|
||||
merged = [dict(i) if isinstance(i, dict) else i for i in (cached or [])]
|
||||
for new_item in new_items or ():
|
||||
if not isinstance(new_item, dict):
|
||||
continue
|
||||
item_id = new_item.get('x.com.samsung.da.id')
|
||||
for i, existing in enumerate(merged):
|
||||
if isinstance(existing, dict) and existing.get('x.com.samsung.da.id') == item_id:
|
||||
merged[i] = {**existing, **new_item}
|
||||
break
|
||||
else:
|
||||
merged.append(new_item)
|
||||
return merged
|
||||
|
||||
|
||||
# /wm/setinfo/vs/0 -- laundry-family firmware capability flags. Present on
|
||||
# washers, dryers, and dishwashers; absent on fridge/oven/AC. Static for the
|
||||
# life of a given board, so reading them from the /device/0 seed (no dedicated
|
||||
|
||||
Reference in new issue