Add cool-only global RAC support: WindFree, Auto mode, display light

Finishes PR #91's contribution (pedroperosin) with the requested review
changes applied, on our own branch:

- Preset resolution is now fully dynamic, read from each unit's own
  /mode/convenient/vs/0 supportedModes instead of a static per-model
  table -- any board's convenient modes (including WindFree's Nano/
  NanoSleep) surface without code changes. Unlabelled codes across
  existing fixtures (longwind, motionindirect, motiondirect, drycomfort)
  plus the two new WindFree ones are added to en.json/nl.json.
- 'Auto' now maps to HVACMode.AUTO instead of HEAT_COOL: these are
  single-setpoint "device decides" units, not two-setpoint heat+cool
  ones. 'Fan' is added alongside 'Wind' as a second FAN_ONLY spelling;
  a new _device_code_for_hvac() picks the code from the unit's own
  supportedModes since the flat map can't disambiguate two device codes
  mapping to one HA value.
- Detection gains a hyphenated '-RAC-' modelNum fallback (alongside the
  existing '_RAC_') for cool-only global RAC variants whose
  /otninformation/vs/0 ships no swVersionInfo block.
- Adds a display_light switch sourced from /mode/vs/0's opaque options
  blob (inverted Light_On/Light_Off token) for boards with no dedicated
  /light/vs/0 switch.

Write-path behavioural change (touches the path iterated on across
#9/#17/#27/#38/#54): power now targets the vendor /power/vs/0 instead of
the OCF /power/0, and _is_on() reads vendor-first. /power/0 is absent on
several known AC boards, so the previous OCF-first read/write pair could
report and act on stale state -- consistent with #53's "can turn on but
not off". Target temperature now picks its channel (OCF pair vs. vendor
items[]) based on which the unit actually reports, reading and writing
the same one.

The vendor temperature write and the new display-light write both carry
only the changed field(s), not the whole resource -- confirmed sufficient
on the wire, the device merges the rest itself. That requires the
coordinator's optimistic cache to do the same merge on the read side so a
setpoint change doesn't blank out current/min/max/unit for the settle
window: common.py gains merge_items_field() next to the existing
merge_options_field(), and async_send_command wires it in for any write
touching x.com.samsung.da.items.

New fixture/golden for the cool-only global RAC variant (TP1X_DA-AC-RAC-
01001, AI_RAC_GLOBAL_COOLONLY_3.0); display_light added to the goldens
for boards that gain the new options-based switch. Regenerated against
current main rather than copied from the original PR, since those
goldens had already shifted (current_temperature_c/humidity from issue
#75).
This commit is contained in:
Marc Billow committed 2026-07-27 05:00:06 +00:00
1 parent af00c2b938
commit fa8f1b8675
19 files changed
+1002 -71

No files matched your search

+7 -5
View File
@@ -746,10 +746,10 @@ async def test_climate_power_write_applies_to_its_own_href_not_bound_href(
"""Regression for issues #17/#53, using the real AC capability. The
composite climate entity binds /mode/vs/0 (airconditioner.CLIMATE.href),
but a power command's write_fn (airconditioner._climate_write) targets
the sibling /power/0 -- the href climate.py's `_is_on()` actually reads.
the sibling /power/vs/0 -- the href climate.py's `_is_on()` actually reads.
The optimistic value and settle guard must land there, not on the bound
/mode/vs/0, or the entity never sees the write and shows stale state
until the next unrelated read of /power/0."""
until the next unrelated read of /power/vs/0."""
from custom_components.localthings.registry.capabilities import airconditioner
from custom_components.localthings.registry.discovery import BoundEntity
@@ -768,9 +768,11 @@ async def test_climate_power_write_applies_to_its_own_href_not_bound_href(
fake.post = lambda *a, **k: (0x44, b'')
await coordinator.async_send_command(bound, ('power', True))
assert coordinator._cache.get('/power/0') == {'value': True}
assert coordinator._cache.get(airconditioner.CLIMATE.href) != {'value': True}
assert coordinator._observe._settle_until.get('/power/0') is not None
assert (coordinator._cache.get('/power/vs/0') or {}).get(
'x.com.samsung.da.power') == 'On'
assert 'x.com.samsung.da.power' not in (
coordinator._cache.get(airconditioner.CLIMATE.href) or {})
assert coordinator._observe._settle_until.get('/power/vs/0') is not None
async def test_send_command_survives_stale_confirm_poll(