Add cool-only global RAC support: WindFree, Auto mode, display light
Finishes PR #91's contribution (pedroperosin) with the requested review changes applied, on our own branch: - Preset resolution is now fully dynamic, read from each unit's own /mode/convenient/vs/0 supportedModes instead of a static per-model table -- any board's convenient modes (including WindFree's Nano/ NanoSleep) surface without code changes. Unlabelled codes across existing fixtures (longwind, motionindirect, motiondirect, drycomfort) plus the two new WindFree ones are added to en.json/nl.json. - 'Auto' now maps to HVACMode.AUTO instead of HEAT_COOL: these are single-setpoint "device decides" units, not two-setpoint heat+cool ones. 'Fan' is added alongside 'Wind' as a second FAN_ONLY spelling; a new _device_code_for_hvac() picks the code from the unit's own supportedModes since the flat map can't disambiguate two device codes mapping to one HA value. - Detection gains a hyphenated '-RAC-' modelNum fallback (alongside the existing '_RAC_') for cool-only global RAC variants whose /otninformation/vs/0 ships no swVersionInfo block. - Adds a display_light switch sourced from /mode/vs/0's opaque options blob (inverted Light_On/Light_Off token) for boards with no dedicated /light/vs/0 switch. Write-path behavioural change (touches the path iterated on across #9/#17/#27/#38/#54): power now targets the vendor /power/vs/0 instead of the OCF /power/0, and _is_on() reads vendor-first. /power/0 is absent on several known AC boards, so the previous OCF-first read/write pair could report and act on stale state -- consistent with #53's "can turn on but not off". Target temperature now picks its channel (OCF pair vs. vendor items[]) based on which the unit actually reports, reading and writing the same one. The vendor temperature write and the new display-light write both carry only the changed field(s), not the whole resource -- confirmed sufficient on the wire, the device merges the rest itself. That requires the coordinator's optimistic cache to do the same merge on the read side so a setpoint change doesn't blank out current/min/max/unit for the settle window: common.py gains merge_items_field() next to the existing merge_options_field(), and async_send_command wires it in for any write touching x.com.samsung.da.items. New fixture/golden for the cool-only global RAC variant (TP1X_DA-AC-RAC- 01001, AI_RAC_GLOBAL_COOLONLY_3.0); display_light added to the goldens for boards that gain the new options-based switch. Regenerated against current main rather than copied from the original PR, since those goldens had already shifted (current_temperature_c/humidity from issue #75).
This commit is contained in:
19 files changed
+1002
-71
No files matched your search
@@ -746,10 +746,10 @@ async def test_climate_power_write_applies_to_its_own_href_not_bound_href(
|
||||
"""Regression for issues #17/#53, using the real AC capability. The
|
||||
composite climate entity binds /mode/vs/0 (airconditioner.CLIMATE.href),
|
||||
but a power command's write_fn (airconditioner._climate_write) targets
|
||||
the sibling /power/0 -- the href climate.py's `_is_on()` actually reads.
|
||||
the sibling /power/vs/0 -- the href climate.py's `_is_on()` actually reads.
|
||||
The optimistic value and settle guard must land there, not on the bound
|
||||
/mode/vs/0, or the entity never sees the write and shows stale state
|
||||
until the next unrelated read of /power/0."""
|
||||
until the next unrelated read of /power/vs/0."""
|
||||
from custom_components.localthings.registry.capabilities import airconditioner
|
||||
from custom_components.localthings.registry.discovery import BoundEntity
|
||||
|
||||
@@ -768,9 +768,11 @@ async def test_climate_power_write_applies_to_its_own_href_not_bound_href(
|
||||
fake.post = lambda *a, **k: (0x44, b'')
|
||||
await coordinator.async_send_command(bound, ('power', True))
|
||||
|
||||
assert coordinator._cache.get('/power/0') == {'value': True}
|
||||
assert coordinator._cache.get(airconditioner.CLIMATE.href) != {'value': True}
|
||||
assert coordinator._observe._settle_until.get('/power/0') is not None
|
||||
assert (coordinator._cache.get('/power/vs/0') or {}).get(
|
||||
'x.com.samsung.da.power') == 'On'
|
||||
assert 'x.com.samsung.da.power' not in (
|
||||
coordinator._cache.get(airconditioner.CLIMATE.href) or {})
|
||||
assert coordinator._observe._settle_until.get('/power/vs/0') is not None
|
||||
|
||||
|
||||
async def test_send_command_survives_stale_confirm_poll(
|
||||
|
||||
Reference in new issue
Block a user