Add cool-only global RAC support: WindFree, Auto mode, display light
Finishes PR #91's contribution (pedroperosin) with the requested review changes applied, on our own branch: - Preset resolution is now fully dynamic, read from each unit's own /mode/convenient/vs/0 supportedModes instead of a static per-model table -- any board's convenient modes (including WindFree's Nano/ NanoSleep) surface without code changes. Unlabelled codes across existing fixtures (longwind, motionindirect, motiondirect, drycomfort) plus the two new WindFree ones are added to en.json/nl.json. - 'Auto' now maps to HVACMode.AUTO instead of HEAT_COOL: these are single-setpoint "device decides" units, not two-setpoint heat+cool ones. 'Fan' is added alongside 'Wind' as a second FAN_ONLY spelling; a new _device_code_for_hvac() picks the code from the unit's own supportedModes since the flat map can't disambiguate two device codes mapping to one HA value. - Detection gains a hyphenated '-RAC-' modelNum fallback (alongside the existing '_RAC_') for cool-only global RAC variants whose /otninformation/vs/0 ships no swVersionInfo block. - Adds a display_light switch sourced from /mode/vs/0's opaque options blob (inverted Light_On/Light_Off token) for boards with no dedicated /light/vs/0 switch. Write-path behavioural change (touches the path iterated on across #9/#17/#27/#38/#54): power now targets the vendor /power/vs/0 instead of the OCF /power/0, and _is_on() reads vendor-first. /power/0 is absent on several known AC boards, so the previous OCF-first read/write pair could report and act on stale state -- consistent with #53's "can turn on but not off". Target temperature now picks its channel (OCF pair vs. vendor items[]) based on which the unit actually reports, reading and writing the same one. The vendor temperature write and the new display-light write both carry only the changed field(s), not the whole resource -- confirmed sufficient on the wire, the device merges the rest itself. That requires the coordinator's optimistic cache to do the same merge on the read side so a setpoint change doesn't blank out current/min/max/unit for the settle window: common.py gains merge_items_field() next to the existing merge_options_field(), and async_send_command wires it in for any write touching x.com.samsung.da.items. New fixture/golden for the cool-only global RAC variant (TP1X_DA-AC-RAC- 01001, AI_RAC_GLOBAL_COOLONLY_3.0); display_light added to the goldens for boards that gain the new options-based switch. Regenerated against current main rather than copied from the original PR, since those goldens had already shifted (current_temperature_c/humidity from issue #75).
This commit is contained in:
19 files changed
+1002
-71
No files matched your search
@@ -93,15 +93,30 @@ def test_air_filter_usage_is_percentage_of_capacity():
|
||||
|
||||
|
||||
def test_climate_write_targets():
|
||||
"""The CLIMATE write_fn maps each (kind, value) command to the right OCF
|
||||
POST target and body. `value` is already the raw device code."""
|
||||
"""The CLIMATE write_fn maps each (kind, value) command to the right vendor
|
||||
POST target and body. `value` is already the raw device code. Power and
|
||||
temperature target the vendor /power/vs/0 and /temperatures/vs/0 (the OCF
|
||||
/power/0 is absent on most boards and a non-authoritative mirror where
|
||||
present; /temperature/desired/0 is only written via the temperature_ocf
|
||||
kind, on boards that have the OCF pair)."""
|
||||
write = airconditioner.CLIMATE.entities[0].write_fn
|
||||
assert write(('power', True), {}) == (['power', '0'], {'value': True})
|
||||
assert write(('power', False), {}) == (['power', '0'], {'value': False})
|
||||
assert write(('power', True), {}) == (
|
||||
['power', 'vs', '0'], {'x.com.samsung.da.power': 'On'})
|
||||
assert write(('power', False), {}) == (
|
||||
['power', 'vs', '0'], {'x.com.samsung.da.power': 'Off'})
|
||||
assert write(('mode', 'Heat'), {}) == (
|
||||
['mode', 'vs', '0'], {'x.com.samsung.da.modes': ['Heat']})
|
||||
assert write(('temperature', 23.6), {}) == (
|
||||
# OCF-pair boards: temperature_ocf -> /temperature/desired/0.
|
||||
assert write(('temperature_ocf', 23.6), {}) == (
|
||||
['temperature', 'desired', '0'], {'temperature': 24})
|
||||
# Vendor boards: temperature -> /temperatures/vs/0, carrying only the id
|
||||
# and the changed field -- the device merges current/min/max/unit itself
|
||||
# (see common.merge_items_field, wired into async_send_command, for the
|
||||
# read-side half that keeps the optimistic cache complete).
|
||||
assert write(('temperature', 22), {}) == (
|
||||
['temperatures', 'vs', '0'],
|
||||
{'x.com.samsung.da.items': [
|
||||
{'x.com.samsung.da.id': '0', 'x.com.samsung.da.desired': '22'}]})
|
||||
assert write(('fan', '2'), {}) == (
|
||||
['wind', 'strength', 'vs', '0'], {'x.com.samsung.da.modes': '2'})
|
||||
assert write(('swing', 'All'), {}) == (
|
||||
@@ -261,6 +276,90 @@ def test_current_limit_is_read_only():
|
||||
assert getattr(desc, 'write_fn', None) is None
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# TP1X_DA-AC-RAC-01001 cool-only global variant (issue #91). Same modelNum as
|
||||
# the issue #38 board above, but its /otninformation/vs/0 ships no
|
||||
# swVersionInfo block, so oneUiVersion is empty and detection must fall back
|
||||
# to the hyphenated '-RAC-' modelNum token (the older '_RAC_' underscore match
|
||||
# doesn't fire on this DA-AC-RAC spelling). Adds /stepcontrol/vs/0 and
|
||||
# /remotedeviceinfo/vs/0 (both ignored) and exposes the WindFree preset via
|
||||
# the Nano/NanoSleep convenient-mode codes. Its panel light is carried inside
|
||||
# /mode/vs/0's options blob instead of a dedicated /light/vs/0 switch.
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
def test_tp1x_rac_coolonly_resolves_via_hyphenated_model_fallback():
|
||||
"""Empty oneUiVersion -> resolved by the '-RAC-' modelNum token, not
|
||||
for_device(). Guards the regression where this unit loaded as 'unknown'."""
|
||||
resources = _load_device('airconditioner_tp1x_rac_coolonly')
|
||||
otn = resources.get('/otninformation/vs/0', {})
|
||||
assert otn.get('swVersionInfo', {}).get('oneUiVersion', '') == ''
|
||||
reg, _ = _resolve('airconditioner_tp1x_rac_coolonly')
|
||||
assert reg is not None and reg.name == 'airconditioner'
|
||||
|
||||
|
||||
def test_tp1x_rac_coolonly_no_unbound_hrefs():
|
||||
"""Every resource binds or is ignored -- including the two hrefs unique
|
||||
to this dump (/stepcontrol/vs/0, /remotedeviceinfo/vs/0). Clears the gap
|
||||
repair."""
|
||||
reg, resources = _resolve('airconditioner_tp1x_rac_coolonly')
|
||||
unbound = []
|
||||
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
|
||||
assert unbound == []
|
||||
|
||||
|
||||
def test_tp1x_rac_coolonly_stray_hrefs_ignored():
|
||||
ignored_hrefs = {cap.href for cap in airconditioner.COVERAGE}
|
||||
assert '/stepcontrol/vs/0' in ignored_hrefs
|
||||
assert '/remotedeviceinfo/vs/0' in ignored_hrefs
|
||||
|
||||
|
||||
def test_tp1x_rac_coolonly_climate_bound():
|
||||
reg, resources = _resolve('airconditioner_tp1x_rac_coolonly')
|
||||
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
|
||||
climate = [b for b in bound if isinstance(b.desc, ClimateDesc)]
|
||||
assert len(climate) == 1 and climate[0].href == '/mode/vs/0'
|
||||
|
||||
|
||||
def test_tp1x_rac_coolonly_display_light_from_mode_options():
|
||||
"""This board has no /light/vs/0 switch; the panel light lives in
|
||||
/mode/vs/0's options and surfaces as a display_light switch. The token is
|
||||
inverted vs its name (confirmed by a live toggle test): with the panel
|
||||
lit the option reads `Light_Off`, and with it dark it reads `Light_On`."""
|
||||
reg, resources = _resolve('airconditioner_tp1x_rac_coolonly')
|
||||
state = flatten(discover(resources, reg.capabilities, reg.pattern_capabilities), resources)
|
||||
assert state.get('display_light') is True
|
||||
|
||||
|
||||
def test_display_light_option_parsing_and_gating():
|
||||
# Inverted token: Light_Off -> panel lit (on), Light_On -> panel dark (off).
|
||||
lit = {'x.com.samsung.da.options': ['CoolCapa_35', 'Light_Off', 'Volume_Mute']}
|
||||
dark = {'x.com.samsung.da.options': ['Light_On']}
|
||||
absent = {'x.com.samsung.da.options': ['Volume_Mute']}
|
||||
assert airconditioner._display_light_on(lit) is True
|
||||
assert airconditioner._display_light_on(dark) is False
|
||||
assert airconditioner._display_light_on(absent) is None
|
||||
assert airconditioner._has_display_light_option(lit, {}) is True
|
||||
assert airconditioner._has_display_light_option(absent, {}) is False
|
||||
|
||||
|
||||
def test_mode_options_display_light_write_is_inverted_single_token():
|
||||
"""Turning the lamp ON writes the inverted 'Light_Off' token as a
|
||||
single-element options list (single-token merge); OFF writes 'Light_On'."""
|
||||
sw = next(e for e in airconditioner.CLIMATE.entities if e.key == 'display_light')
|
||||
assert sw.write_fn('On', {}) == (
|
||||
['mode', 'vs', '0'], {'x.com.samsung.da.options': ['Light_Off']})
|
||||
assert sw.write_fn('Off', {}) == (
|
||||
['mode', 'vs', '0'], {'x.com.samsung.da.options': ['Light_On']})
|
||||
|
||||
|
||||
def test_light_switch_board_gates_out_mode_options_light():
|
||||
"""Boards with a real /light/vs/0 switch carry no Light_* option, so the
|
||||
mode-options display-light entity doesn't double up (mutually exclusive
|
||||
encodings)."""
|
||||
reg, resources = _resolve('airconditioner_tp1x_rac')
|
||||
assert airconditioner._has_display_light_option(resources['/mode/vs/0'], resources) is False
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# WindFree unit (issue #75): same ARTIK051_PRAC_20K modelNum family as the
|
||||
# original issue #17 fixture, but its /mode/convenient/vs/0 additionally
|
||||
|
||||
Reference in new issue