airconditioner: ungate outdoor_temperature from is_legacy_board
The OutdoorTemp_ options token was only surfaced on legacy boards (is_legacy_board), even though 14 of 17 fixtures carrying the token are non-legacy. issue #367 confirmed with a 48h field capture (r=0.92 against weather.forecast_home) that the token tracks real outdoor temperature independent of board generation, and that no non-legacy board exposes an alternative outdoor-temperature resource. Split a token-presence-only exists_fn (_has_option_token_any_board) for this token, leaving _has_option_token's legacy gate untouched for the other options[] settings that still need it. The -55 offset itself was only field-validated on Celsius-locale boards, so a second gate (_reports_celsius, reading the board's own /temperatures/vs/0) keeps the sensor off the one Fahrenheit-locale fixture on record rather than guess whether the same offset and unit still apply there. Ships enabled_default=False since multi-split installs report the same token on every indoor head, which would otherwise create one duplicate active sensor per head. Updates the golden fixtures for the 13 affected Celsius-locale boards and the artik051_krac test that had asserted outdoor_temperature stays off newer boards; adds coverage for the Fahrenheit-locale gate.
This commit is contained in:
3 files changed
+43
-9
No files matched your search
@@ -22,7 +22,6 @@
|
||||
"mute_once",
|
||||
"odor_controller_active",
|
||||
"odor_controller_progress",
|
||||
"outdoor_temperature",
|
||||
"power_watts",
|
||||
"tropical_night_mode"
|
||||
]
|
||||
|
||||
@@ -654,6 +654,22 @@ def test_lnx_rac_heatpump_no_unbound_hrefs():
|
||||
assert unbound == []
|
||||
|
||||
|
||||
def test_lnx_rac_heatpump_outdoor_temperature_stays_off_fahrenheit_boards():
|
||||
"""issue #367's -55 offset was field-validated on Celsius-locale boards
|
||||
only; this fixture's own /temperatures/vs/0 declares Fahrenheit despite
|
||||
carrying an OutdoorTemp_ token, so the sensor stays off rather than
|
||||
apply an unvalidated offset/unit to it (see _reports_celsius)."""
|
||||
reg, resources = _ac_lnx_rac_heatpump()
|
||||
temps_item = resources["/temperatures/vs/0"]["x.com.samsung.da.items"][0]
|
||||
assert temps_item["x.com.samsung.da.unit"] == "Fahrenheit"
|
||||
options = resources["/mode/vs/0"]["x.com.samsung.da.options"]
|
||||
assert any(o.startswith("OutdoorTemp_") for o in options)
|
||||
|
||||
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
|
||||
state = flatten(bound, resources)
|
||||
assert "outdoor_temperature" not in state
|
||||
|
||||
|
||||
def test_lnx_rac_heatpump_absence_power_saving_state():
|
||||
reg, resources = _ac_lnx_rac_heatpump()
|
||||
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
|
||||
|
||||
Reference in new issue