The investigation is written around the FilterTime_<N> option token on
/mode/vs/0, and its conclusion holds for the ARTIK051_KRAC_18K it was
measured on. An ARTIK051_PRAC_20K has no such token: no FilterTime, no
FilterAlarmTime, no FilterCleanAlarm anywhere in its options blob. It
keeps the counter in /filter/airdustfilter/vs/0 as a percentage of a
500-hour interval instead.
Neither route resets it. FilterCleanAlarm_Clear to /mode/vs/0 returns
4.00 with the options blob byte-identical; writing filterUsage as the
string "0" returns 4.00; writing it as an integer returns 5.00. That
last difference is the useful part — two payloads differing only in JSON
type returning different codes rules out an unresolved href or an
unrecognised field name, leaving read-only as the reading.
Adds a scope line to the intro and a section documenting the board, its
two resource dumps, the attempt table, and an observation-only
workaround for percentage-counter boards.
FilterCleanAlarm_Clear, through the same single-token options merge as every
other setting on /mode/vs/0. Measured on an ARTIK051_KRAC_18K: 2.04 Changed and
FilterTime_95 (9 h 30 min) -> FilterTime_0, still zero on a fresh DTLS session
and on every poll after; none of the other 17 tokens moved and the alarm
entries stayed Deleted.
The counter has had no reset until now, and the descriptor said so: two earlier
rounds against live hardware failed, and the conclusion drawn from them was
that the reset had to be cloud-only. That conclusion was wrong, and the way it
was reached is the interesting part -- it came from diffing every resource the
appliance reports before and after pressing reset in Samsung's app, which
showed only the counter zeroing and the alarm clearing. A trigger token cannot
show up in such a diff, because a trigger is never stored. The appliance's own
app sends this token and skips the write when the counter is already zero.
Both failures stay in the comment, because they say what this is not: writing
FilterTime_0 (the value is not writable -- 5595 -> 5595 after 69 s, 1925 ->
1925 after 65 s, two units, opposite power states), and POSTing the cloud
capability's command name to /actions/vs/0 (real name, wrong transport).
Gated on the FilterTime_ token, so it appears only where there is a counter to
reset; newer boards report filter usage through their own resource and would
need a different mechanism.
CONTRIBUTING.md gains a "Code comments" section: comment the why not
the what, keep it to a sentence or two with a pointer to the load-bearing
evidence, don't re-derive a sibling's already-documented reasoning, and
move failed-attempt investigation logs out of inline comments.
Applied that policy across the codebase: condensed sprawling module
docstrings, per-entity essays, and multi-paragraph rationale blocks down
to their load-bearing conclusions, while preserving the actual "why"
(issue numbers, calibration evidence, gotchas, don't-guess rationale).
No functional code changed — verified via diff review, ruff, ty, and the
full pytest suite (1211 passed).
One inline investigation log (the AC filter-reset "tried and failed"
notes) moved to docs/investigations/ac-filter-reset.md rather than being
deleted, per the new guideline on where that kind of record belongs.