8 Commits
Author SHA1 Message Date
JayChickenK 171316bd95 air_purifier: share has_sensor_type and disable co2 by default
Hoist airconditioner._has_sensor_type to common.has_sensor_type next to
sensor_item_value, add the issue #127 stub-rep carve-out, and match the
AC family's enabled_default=False on the purifier CO2 entity.
2026-08-19 18:27:01 +02:00
JayChickenK 258cdc1647 tests: apply ruff format to CO2 assertions 2026-08-18 11:07:51 +02:00
JayChickenK 33a06b9ae8 air_purifier: expose CO2 when the device lists it
Issue #387's TP1X_DA-AC-AIR-class board reports a CO2 item on
/sensors/vs/0. Same field/shape air_monitor.SENSORS already models
(carbon_dioxide / ppm). Gated with exists_fn so boards that don't
list the type (every current fixture) don't grow an empty entity.
2026-08-18 11:04:25 +02:00
Marc Billow eeece4906c Type air_monitor's particulates and migrate the recorded statistics
Adding a unit to a sensor that recorded long-term statistics without one
is not cosmetic: Home Assistant raises a units_changed repair and then
*suppresses statistics generation* for that entity until a human resolves
it (sensor/recorder.py's compile path hits `continue`). Shipping the PM
device classes on their own would therefore have silently frozen the very
history the labels were meant to describe.

A v2 -> v3 config-entry migration relabels the statistics metadata first.
It rewrites only the metadata row, never the recorded values -- these
readings were always µg/m³ and only the label was missing, so nothing
needs converting, which is why this uses async_update_statistics_metadata
and not change_statistics_unit. It reads entity_ids back off the entity
registry rather than rebuilding them from descriptor keys, since a renamed
entity's statistic_id no longer follows from its key, and it is scoped by
device family: range_hood and airconditioner still declare no unit for
their identically-named sensors, so relabelling theirs would create the
exact mismatch this exists to prevent.

With the migration in place there is no longer a reason to hold the labels
back on air_monitor, so it takes them too. That board is one of the two
whose fixtures pin the grade bands the mapping rests on -- typing the
purifier and not the monitor was an inconsistency, not caution. It still
declines the shared state_class column, unchanged.

Recorder coupling is guarded: after_dependencies pulls it in when
configured, the import is local to the migration, and a setup without it
is a no-op. Freshly created entries mint v3 directly, having no history to
relabel.

Tested at both levels. The unit-level tests patch the recorder and assert
which entities are relabelled with which arguments, covering the renamed
entity, subdevice-prefixed and instanced keys, the near-miss keys
(dustbag_/dustbin_), the skipped families and the recorder-absent path.
Because a mock can only prove the call is made, not that it does what the
migration needs, a second suite drives a real in-memory recorder end to
end: statistics seeded unitless, migration run, metadata confirmed to read
µg/m³ / concentration, recorded means confirmed byte-identical, and the
units_changed issue confirmed present before and absent after.
2026-08-15 01:01:49 +00:00
Marc Billow 21af5708cb Fix PM unit codepoint and document the /sensors/vs/0 grade column
Review follow-up to PR #365, which landed the washer 0A/B0 labels and the
air-purifier PM device classes.

The three particulate units were spelled with U+00B5 MICRO SIGN. Home
Assistant's DEVICE_CLASS_UNITS holds only the U+03BC GREEK SMALL LETTER MU
spelling, so every purifier logged a per-entity "not a valid unit for the
device class" warning asking the user to file a bug against us. The two
characters render identically, and the PR's own test hardcoded the wrong
one, so the test agreed with the bug. That test now takes the expected
unit from HA's own constant, and a new registry-wide guard
(test_sensor_device_class_units.py, mirroring the SwitchDesc guard from
issue #349) checks every SensorDesc unit against HA -- these were the only
three invalid pairs among 29.

Getting this in before release matters more than usual: the recorder
writes unit_of_measurement into long-term statistics, so correcting it
afterwards would raise a "units changed" repair for anyone who had run the
released version.

Also settles what the second element of a dust reading's value[] is, which
was the open question behind issue #325's request for another dump. It is
the device's own graded air-quality level: it appears only on the fields
carrying a magnitude (Dust/FineDust/SuperFineDust/CO2) and not on
Odor/CleanLevel, which are grades already; it reads 0-2 against index 0's
0-31; and CleanLevel equals the highest per-field grade on 9 of the 11
fixtures reporting the resource. It stays unbound -- ARTIK051_TVTL grades
good air as 0 while every other family uses 1, so a shared descriptor
would need a per-family offset -- but it is what confirms the PM mapping
without relying on field names: 18 grades one step above the floor as
SuperFineDust yet sits at the floor as Dust, on two families that both
floor at 1, so the firmware itself treats the three fields as different
scales ordered coarse-to-fine. Each field's floor boundary also brackets
the Korean CAI band for its tier (PM10 at 30/31, PM2.5 at 15/16). Pinned
against the shipped fixtures in test_air_quality_grade_column.py.

air_monitor keeps its untyped sensors, but the docstring now gives the
real reason: the evidence carries over, and what is deliberately deferred
is the statistics migration for entities shipped unitless since issue #210.

Smaller fixes: en.json's "Mixed load" -> "Mixed Load" to match the
catalog's title casing and issue #363's own wording; de/ko gave B0 the
same string as the existing "34" Mixed, so a machine exposing both showed
two identical options; washer.py's shared-label list still said "'24'
Towels", which went stale when issue #343 found 24/33 transposed; and
0A/B0 now have a locale-wide translation guard like every other confirmed
code batch.
2026-08-15 00:23:53 +00:00
JayChickenK 627b761462 washer: add 0A/B0 cycle labels; purifier: PM device classes
Table_02 codes 0A (Towels) and B0 (Mixed load) were reported for a
WW90DG5G34ABLE (issue #363). Air-purifier Dust/FineDust/SuperFineDust
map to PM10/PM2.5/PM1 in µg/m³ from a same-moment SmartThings
correlation (issue #325).
2026-08-15 00:17:09 +00:00
kkqq9320 15279066b5 review: move the state_class into the shared tuple's fourth column
The frozenset was a parallel structure for a per-row fact, and the comment
above the tuple already described it as a fourth column -- so the comment
promised the right shape and the code did something else. Fixed to the shape
the comment described: _AIR_QUALITY_SENSORS carries state_class per row and
the comprehension unpacks it, with _RECORDED_AIR_QUALITY and its duplicated
rationale block deleted.

air_monitor imports the same rows and now unpacks four, but discards the
fourth. That board (issue #210) has stamped all five readings as
`measurement` since it was added; consuming the column would silently drop
long-term statistics for Odor and CleanLevel on shipped devices, which is a
behaviour change this branch has no evidence to make. The grade/concentration
split stays scoped to the air purifier.

test_shared_sensor_tuple_keeps_its_three_column_shape asserted the premise
this replaces -- that widening the tuple breaks air_monitor's import -- so it
is replaced rather than renumbered: one test that the rows carry their own
state_class, and one that air_monitor still imports and still stamps all five.
2026-08-04 15:25:12 +09:00
kkqq9320 69844d9829 fix(air_purifier): record long-term statistics for the particulate sensors
dust / fine_dust / super_fine_dust show live values fine but Home Assistant
keeps no long-term statistics for them, so once recorder's purge window passes
(10 days by default) the history is gone and they can't back a long-range
air-quality graph.

HA only writes long-term statistics for sensors that declare a state_class,
and AIR_QUALITY's descriptors set none -- the entities come up carrying just
an icon. The values were never the problem: common.sensor_item_value already
returns int. Three sensors in this same module (filter_progress,
fan_speed_level, hepa_filter_usage) already declare one, so this reads as an
oversight rather than a decision.

Only the three particulate readings are stamped. They fall monotonically with
particle size on three independent board families -- 11/9/5 on ARTIK051_TVTL
(issue #56), 10/9/6 on AVT-WW-TP1 (issue #190), 18/14/9 on the range hood --
which is concentration behaviour, and averaging it over time is meaningful.
Odor and CleanLevel read 0-2 on every fixture and look like graded indices,
where the mean of a grade isn't obviously meaningful, so they are left alone
rather than guessed into statistics.

Worth flagging for the review: air_monitor.SENSORS already stamps all five of
these, and its module docstring describes that as "matching
air_purifier.AIR_QUALITY's existing precedent" -- a precedent this module did
not actually set. Extending to all five here is a one-line change if
consistency is preferred over the grade/concentration split.

The state_class is carried in a separate key set rather than a fourth tuple
column because air_monitor.py imports _AIR_QUALITY_SENSORS and unpacks it as a
triple; widening it breaks that module's import outright. Two of the new tests
guard exactly that coupling.

No device_class or unit is asserted: pm1/pm25/pm10 with µg/m³ would claim the
reading is a mass concentration, which no dump states. That is a separate call
from making the series recordable at all.

Metadata only -- no key, name, value or unit changes, so no entity changes
identity and every golden is untouched. Statistics start accumulating from the
upgrade onward; existing short-term history is unaffected.
2026-08-03 14:34:57 +09:00