81dbc6fa03 |
Key devices on the OCF device ID instead of the serial number
Two Samsung air purifiers of the same model report the identical, well formed serialNum `BS7SP9AW400114A` (issue #381). Since the entry's unique_id, the device registry identifiers and every entity unique_id were all minted from that string, the second unit was refused as already configured, and would have collided entity-for-entity even if it hadn't been. This is the third firmware family to ship an unusable serialNum, after `Nothing(SVC)` (#83) and the flash-unset sentinel (#189), and the first one no heuristic can catch: the value is well formed, it's just shared. `is_placeholder_serial` was a dead end. So identity moves onto /oic/d's `di`, falling back to /oic/p's `pi`, then the serial, then the host. `di` is what the protocol already uses to address the endpoint -- if it were wrong or shared, OCF discovery and the DTLS association wouldn't work at all -- and it's device-scoped, where `pi` is platform-scoped and would be shared by a board hosting several logical devices. Both units in #381 report a distinct `di`. A board that answers neither resource lands exactly where it did before, so no existing hardware regresses. The re-key can't happen in async_migrate_entry: the UUID is only readable from the device, and an entry can load entirely from its snapshot while the appliance is off (#295). So v3 -> v4 only records the legacy key, and the coordinator adopts the UUID on the first live poll, rewriting the entity registry, the device registry (including subdevice identifiers) and the entry's unique_id together. Rewriting rather than recreating is what lets a user keep entity_ids, names, areas, statistics and every automation that references them. Three rules keep that adoption from misfiring: - A poll that reads no UUID never demotes a UUID-keyed entry back onto its serial, so one failed reconnect doesn't re-key every entity. - A changed UUID is followed only when the serial still corroborates it (a factory reset may regenerate `di`) or when the entry was keyed on its IP, which was never an identity to defend. - When the identity is rejected as a different appliance, the serial isn't adopted either -- otherwise the intruder would gain exactly the corroboration needed to win the next poll. Also stop redacting `di`/`pi` from diagnostics. They're randomly assigned per-unit UUIDs, not account data, and blanking them is what made the first #381 diagnostics download unable to answer the only question it was requested to answer. The owner-set device name stays redacted. Fixes #381 |
||
|
|
daf7e3787f |
Add ruff (lint + format) and ty (type checking) to the project
Adds [tool.ruff] and [tool.ty] config to pyproject.toml with a curated ruff rule set (E, F, W, I, UP, B, C4, SIM, RUF, ASYNC, LOG, G, PIE, RET, PERF, N), pins ruff/ty in requirements-dev.txt, reformats the whole tree with `ruff format`, and fixes the pre-existing lint and type-check debt those tools surfaced so both run clean. Production-code type fixes include: HA's ConfigFlowResult vs. the generic FlowResult in config_flow.py, narrowing BoundEntity.desc to its platform-specific subclass (SelectDesc/NumberDesc/SensorDesc/etc.) via cast() instead of an unchecked annotation, converting HA device_class strings to their proper enum types, a resolve_registry callback typed as `object` instead of `DeviceRegistry | None`, and a couple of other narrow correctness fixes (CA key type validation, an index-out-of-bounds false positive from an empty-tuple fallback, a bool/dict argument swap). Test-file fixes are mechanical: narrowing SamsungEntityDescription to the correct subclass via isinstance()/cast() before accessing subclass-only fields, and asserting Optional write_fn/unit_fn fields are set before calling them. |
||
|
|
9e85395b44 |
rename: unit/sub-unit -> subdevice, matching OCF terminology
"Unit"/"sub-unit" from #199's multi-indoor-device support wasn't OCF idiomatic -- OCF calls each component of a composite device a "subdevice" (see subdeviceIdList), so rename SubUnit -> Subdevice throughout: the registry module, coordinator state, BoundEntity's subdevice field, diagnostics keys (subdevices/subdevices_skipped/ subdevice_probes), entity unique_id prefixes (unit1_/sub_<uuid>_ -> subdevice1_/subdevice_<uuid>_), device-name fallback labels, golden fixtures, tests, README, and the adding-device-support skill. Breaking change to entity unique_ids and diagnostics keys, acceptable since this hasn't been released yet. |
||
|
|
c181a8b447 |
feat(subdevices): support multi-indoor-unit systems (#177)
Samsung 2-in-1 air conditioners put more than one logical indoor unit behind a single IP and a single DTLS session. Only the unit the config entry was set up against was ever discovered; the second one -- a whole physical appliance the user can see in SmartThings -- had no entities at all. Two reporters turned out to have two different mechanisms: ARTIK051_DONGLE_FAC_18K -- indexed siblings. /oic/res registers the whole tree discoverable and lists three complete parallel resource sets whose trailing path segment is the index (/mode/vs/0, /mode/vs/1, ...), on OCF-standard and vendor hrefs alike. /device/0's batch carries only the index-0 hrefs, so a sibling is reachable only through its own /device/<n> collection. TP2X_FAC_BORA_21K -- UUID-prefixed tree. /oic/res hides the appliance tree entirely (which is why a direct /device/1 probe returns nothing on this board). /subdevices/vs/0 carries subdeviceIdList instead, and that UUID appears as a literal href prefix; /<uuid>/information/vs/0 was confirmed live to return the wall unit's own model and serial (TP2X_FAC_BORA_RAC_21K) against the master's TP2X_FAC_BORA_21K. The detection signals don't overlap on either board, so no disambiguation is needed -- enumeration checks both and takes what answers. Both patterns are the same thing underneath: a logical unit is a seed collection path to poll plus an href transform between the canonical href the registry knows and the actual on-the-wire href. That is the whole abstraction (SubUnit), applied at four boundaries -- discovery, the coordinator, the adapter, and the platforms. Capabilities, the registry and the climate composite stay written against canonical hrefs and are untouched. Uniqueness comes from a key_prefix inside the flattened state key, so the master unit's keys are byte-identical to every release before this and every existing golden file is an unchanged regression guard. Each sub-unit gets its own device-registry entry linked by via_device and named from its own /information/vs/<n>, so it lands in its own room rather than crowding the master's device page. A sub-unit materializes only when it yields at least one primary (non-diagnostic) entity with a populated value. That gate is not decoration: the reporter's /device/2 is an unused slot that SmartThings shows disabled, yet it answers with a full 14-href batch, and it flattens to exactly one non-None value -- a diagnostic alarm_code derived from an empty /alarms/vs/2. Without the entity-category filter it becomes a phantom third climate card. The rule is deliberately domain-agnostic rather than a list of HVAC hrefs, so a multi-drum washer (#19) gets the same treatment with no new curation. Units that answer but fail the gate are logged and reported in diagnostics, so a genuinely missing unit stays diagnosable from a dump. Enumeration fetches things that must not then be treated as appliance state. A rejected candidate's seed has to be read to evaluate the gate, but only units that pass are polled again, and StateCache has no eviction -- so discovery runs before the first cache apply and those reps are held aside for diagnostics rather than frozen into the cache forever. /multidevice/vs/0 is probed on every device regardless of family, so merging it into the resources dict would have reached discovery on any board whose registry doesn't ignore that href -- only the air conditioner one does -- raising a spurious coverage-gap repair for a washer or fridge whose firmware answers it. It is corroborating metadata (numofsubdevice, confirmed read-only) and now lives beside the resources rather than in them. Diagnostics reports each unit separately: top-level `resources` is this unit's own and only its own, which is what the module docstring and the adding-device-support skill have always claimed it was, and each sibling or rejected candidate carries its own reps canonicalized so a block reads exactly like the master's instead of needing to be de-indexed by hand. Fixtures are real captures. The ARTIK051_DONGLE_FAC_18K one is entirely verbatim, both sibling seeds and the hand-read /multidevice/vs/0 included. The TP2X_FAC_BORA one has a real device0, oic_res and sub-unit /information/vs/0, with the remainder of that unit's tree constructed and documented as such in seeds_note; /<uuid>/device/0 is the one part of that pattern still inferred rather than observed, and can't be tested through the debug panel because a Collection returns a list. |
||
|
|
2be742489b |
Fix airflow fan power-href preference and unique_id collision risk
Opus review of the previous commit caught two real bugs. The airflow fan's power writes preferred /power/vs/0, copied from the TP1X fan class -- but that order is only harmless there because TP1X never reports /power/0 at all. This family's dumps carry both hrefs, and the power_switch entity is unconditionally bound to /power/0 when present, so the fan was writing to a different resource than power_switch reads/writes, leaving the two entities disagreeing until the next poll. Flipped to prefer /power/0, matching the range hood's fan and common.POWER_GENERIC. Also renamed the new FanDesc's key from 'fan' to 'airflow_fan': BoundEntity unique_ids are derived from key alone, not href, so it collided with air_purifier.FAN's own 'fan' key on the (currently unobserved, but unenforced) possibility of a board reporting both. Added a platform-level test file covering the power-href preference and percentage<->speed-code mapping, mirroring test_range_hood_fan.py's harness. |