Commit Graph
12 Commits
Author SHA1 Message Date
Marc Billow 8b45d8cbf6 Merge branch 'main' into claude/device-support-issue-77-freezer 2026-07-26 21:40:51 -05:00
Marc Billow 643aac92f8 Lock in the same ARTIK051_DONGLE_REF fix for the fridge half (issue #78)
RR40M7165WW is the fridge half of the same household dongle setup as
issue #77's freezer -- identical pipe-delimited ARTIK051_DONGLE_REF
modelNum, so the previous commit's detection and door-sensor fixes
already cover it with no further code changes. Add its fixture as a
second, independent regression case: it exercises the 'cooler' instance
segment instead of 'freezer' for both the temperature pattern caps and
DOOR_GENERIC, and notably reports /door/onedoorfreezer/vs/0 despite
being a single-door fridge (shared firmware naming across the product
line, not an actual second compartment) -- worth having its own golden
so that stays working too.
2026-07-27 00:41:25 +00:00
Marc Billow 8194ea9e87 Fix ARTIK051_DONGLE_REF freezer type detection and door sensor (issue #77)
RZ32M713EWW/EE (an ARTIK051-dongle standalone freezer) reports no
oneUiVersion and a pipe-delimited modelNum
('ARTIK051_DONGLE_REF|<rest>') -- REF is the last underscore segment
before the pipe, not wrapped in underscores on both sides like the
'..._REF_...' shape for_device_by_model's substring check expected, so
the device fell through to 'unknown' with only common capabilities:
no door sensor, no temperature sensors, nothing fridge-specific.

Replace the substring check with a segment-based one
(_model_num_segments splits the pipe-delimited prefix on '_') that
catches both shapes. Same root cause, same fix, and same device family
independently reported and root-caused in issue #83 (which also covers
two further bugs -- config-flow/coordinator serial collisions on a
second symptom of this firmware, 'Nothing(SVC)' as a literal serial --
not needed here since this reporter has a single unit; left for #83).

Once routed to the refrigerator registry, fridge.py's existing pattern
capabilities pick up /temperature/current/freezer/0 and
/temperature/desired/freezer/0 for free -- they were never the actual
problem, just unreachable under the 'unknown' fallback (which never
tries pattern capabilities at all). The door sensor needed one more
fix: /door/onedoorfreezer/vs/0 reports the vendor-prefixed
x.com.samsung.da.openState, not the bare openState DOOR_GENERIC read,
so the entity existed but stayed permanently unavailable. Check both
field names via rep_fn.
2026-07-27 00:39:33 +00:00
vmvarga 2fd8ff8260 merge temp_setpoint 2026-07-26 11:05:13 +02:00
Rob Martin 9cf1e46bf6 fix(fridge): stop switch turn-off silently sending 'On'
Six fridge SwitchDesc write_fns built their payload with
`'On' if p else 'Off'`. The switch platform passes the literal
string 'Off' on turn-off, which is truthy, so the guard always
produced 'On' -- turning these switches off silently re-sent On
and they could never be turned off:

  - ICEMAKER_NIGHTTIME (ice.night.status)
  - STATUS_LOCK helper (devicecontrol + device.sound)
  - DEFROST_DELAY (delayDefrost)
  - WELCOME_LIGHTING (status)
  - CABINET_LIGHT dim (light.dimming.status)
  - ICEMAKER_STATUS_FALLBACK (iceMaker)

Compare `p == 'On'` instead, matching the pattern the other
capability files already use. Adds a regression test asserting
every affected write_fn sends 'Off' on 'Off' and 'On' on 'On'.
2026-07-24 12:11:53 -06:00
Marc Billow 3d5263d792 Add common.UNIVERSAL/POWER bundles to stop hand-duplicating capabilities
FIRMWARE_UPDATE and ALARMS were already copy-pasted into all 6 device-type
registries by hand; POWER/KIDS_LOCK/REMOTE_CONTROL into 5 of 6. Consolidate
into two bundles in common.py, unpacked via *common.UNIVERSAL / *common.POWER
the same way ignored.IGNORED already is:

- UNIVERSAL: ALARMS, ENERGY_METER, FIRMWARE_UPDATE (moved from fridge.py),
  SELF_CHECK (moved from fridge.py), AI_ENERGY_LEVEL, and the kids-lock/
  remote-control pairs. Safe everywhere -- discover() only binds a href
  actually present in a device's dump, so a capability with no known
  conflicting family is a no-op where the href is absent and a real,
  wanted entity where it's present. This also broadens AI_ENERGY_LEVEL,
  ENERGY_METER, and SELF_CHECK to device types they weren't confirmed on
  before, on the same reasoning.
- POWER: just POWER_GENERIC/POWER_VS_FALLBACK, applied to the 5 non-AC
  registries. Airconditioner keeps its own opt-out: its climate entity
  already owns /power/0 and /power/vs/0 via a bare, no-entity claim
  (airconditioner.COVERAGE), and a real power capability on the same
  href would make _build() raise (a href with multiple caps requires
  every cap to have rt_filter or match_fn; the bare COVERAGE cap has
  neither).

Full test suite (327 tests, all 6 device-type golden fixtures) passes
unchanged -- none of the newly-broadened capabilities bind on any existing
fixture, confirming the no-op reasoning held in practice, not just theory.
2026-07-23 00:44:58 +00:00
Marc Billow d6639c99d4 Bind AI energy level on washer; switch/select split, drop translations
Issue #40: /energy/ailevel/vs/0 was unbound on a plain washer. The
capability already existed for fridges but was gated off entirely on
single-level hardware (the common case), so it's moved to common.py
(cross-family, like fridge + washer now) and split into two entities:
a switch when supportedAiLevel has exactly one entry (aiLevel is really
just an on/off toggle there), and a select otherwise, with '0' (off)
synthesized back into the select's options since supportedAiLevel never
lists it but it's a real observed value.

Also drops the translation_key/strings.json entries -- aiLevel's raw
digit values already render fine untranslated, and translating a
handful of levels can't cover devices with more.
2026-07-23 00:44:57 +00:00
Tim Schindler 0cc9d8e511 fix: render selfcheck_error as no-value on empty list; document ai_energy_level level labels 2026-07-22 09:04:24 +02:00
Tim Schindler 2a0a9f32ee feat: add AI energy level select and self-check error sensor for fridges
Adds two small, additive fridge capabilities:

- AI_ENERGY_LEVEL: a select on /energy/ailevel/vs/0 exposing the AI
  energy-saving level, gated behind supportedAiLevel actually offering
  more than one choice (previously globally ignored since every dump
  seen only reported a single supported level).
- selfcheck_error: a diagnostic sensor on the existing SELF_CHECK
  capability surfacing x.com.samsung.da.error from the last self-check,
  for hardware that reports it.

This does not touch FLEX_ZONE, /mode/vs/0, or /icemaker/status/0.
2026-07-22 08:42:31 +02:00
Marc Billow 9a899080fa fix: fridge/washer coverage gaps from the #19-#27 dump batch
Six new diagnostics dumps, six gaps closed:

- refrigerator: bind /diagnosis/vs/0 (reuse dishwasher.DIAGNOSIS -- same
  shape) into the refrigerator registry; it was never wired up there,
  tripping the coverage repair on any fridge that reports it (#20, #26).
- refrigerator: add PANTRY_ZONE for the Cool Select Zone pantry compartment
  (/status/pantry/one/vs/0, x.com.samsung.da.mode/supportedOptions) -- same
  shape as BEVERAGE_ZONE but a distinct resource/field set (#20).
- refrigerator: generalize FLEX_ZONE to identify the current mode by list
  membership in supportedOptions instead of a hardcoded
  CV_TTYPE_RF9000A_ prefix check. TP1X/Bespoke-class fridges use a
  CV_FDR_ prefix instead, which the old code didn't recognize -- the
  select existed but always read as unknown, and writing to it would have
  appended a duplicate CV_FDR_ flag rather than replacing the existing one
  (#26, #27; also closes #32).
- common: add energy_saved_kwh (x.com.samsung.da.cumulativeSavedPower) and
  power_energy_kwh (x.com.samsung.da.cumulativeConsumption) to the shared
  energy meter, plus fridge-only energy_last_month_kwh/energy_this_month_kwh
  (monthlyConsumption/thismonthlyConsumption) -- all self-gating on field
  presence (#26).
- by_type: add the WV consumer-model prefix (FlexWash twin washers, e.g.
  WV55M9600AW) to the by-model fallback map. These report no oneUiVersion
  and previously matched no prefix at all, so they fell all the way
  through to the unrecognized-device registry with zero capabilities
  bound (#19).
- washer: add a self-gating dry_level select to WASHER_SETTINGS for
  washer/dryer combo units, which carry a writable dryLevel field
  directly on /washer/vs/0 with no separate dryer resource or course
  (#22).

The reset-water-filter button and "ice type vs. two named icemakers"
requests from #26/#27 are left alone -- no write contract or exclusivity
behavior is evidenced in either dump, and both icemakers report On
simultaneously on the Bespoke unit, so synthesizing a single-select would
be a guess rather than a fix.

Adds scrubbed fixtures + goldens for FlexWash, a washer/dryer combo,
ARTIK051_REF_17K, and TP2X_REF_20K, plus unit tests for the new/changed
capabilities.
2026-07-22 06:11:15 +00:00
themaanda 6f53b3043b Cover TP1X refrigerator native resource mirrors 2026-07-21 16:58:42 -05:00
Marc Billow e875266405 fix(washer,fridge,oven): correct energy/temperature-unit bugs from issues #6/#7
Washer (#6): instantaneousPower is a dead sentinel ('-500') on every
TP1-class washer dump collected so far, and cumulativePower is absent
outright on at least one model. WASHER_ENERGY_METER now hides both
sensors instead of showing a misleading "0 W"/perpetual "unavailable".

Fridge (#7): temperature sensors/setpoints hardcoded '°F', ignoring the
unit each device actually reports per-reading -- fixed via a new
unit_fn hook read live from the resource. Also corrects
DEFROST_BLOCK_STATUS's polarity (DEFROST_BLOCK_ON means actively
defrosting, not "blocked", confirmed against live dumps) and adds
REFRIGERATION_FALLBACK for /refrigeration/0, closing the last unbound
href surfaced by issue #7's diagnostic dump.

Oven: applies the same live-unit-reading fix defensively to
OVEN_SETPOINT, which shares the same aggregate resource shape.
2026-07-15 11:41:21 -05:00