Commit Graph
11 Commits
Author SHA1 Message Date
Marc Billow 43542b146f fix: restore empty-stub carve-out on the new energy sensors; dedupe flex-zone set build
Review follow-up (Opus + /simplify) on the previous commit:

- power_energy_kwh/energy_saved_kwh/energy_last_month_kwh/
  energy_this_month_kwh used a plain `field in rep` exists_fn, unlike their
  siblings power_watts/energy_kwh in the same capability. Per
  entity._is_included, an explicit exists_fn bypasses the stub carve-out
  entirely -- an empty {} rep at platform setup (device/0 returned a
  not-yet-fetched stub) would permanently drop these entities for the
  session instead of picking them up once a sub-poll populates the
  resource. Restore the same `not rep or ...` guard used above.
- fridge._flex_zone_current/_flex_zone_write independently rebuilt the same
  supportedOptions set; factor into _flex_zone_supported.
- note in a comment that the flex-zone match assumes at most one
  modes/supportedOptions overlap (true on every dump seen); add the
  missing negative assertion that dry_level self-gates off on a plain
  washer (was only positively asserted on the combo fixture).
2026-07-22 06:11:16 +00:00
Marc Billow 9a899080fa fix: fridge/washer coverage gaps from the #19-#27 dump batch
Six new diagnostics dumps, six gaps closed:

- refrigerator: bind /diagnosis/vs/0 (reuse dishwasher.DIAGNOSIS -- same
  shape) into the refrigerator registry; it was never wired up there,
  tripping the coverage repair on any fridge that reports it (#20, #26).
- refrigerator: add PANTRY_ZONE for the Cool Select Zone pantry compartment
  (/status/pantry/one/vs/0, x.com.samsung.da.mode/supportedOptions) -- same
  shape as BEVERAGE_ZONE but a distinct resource/field set (#20).
- refrigerator: generalize FLEX_ZONE to identify the current mode by list
  membership in supportedOptions instead of a hardcoded
  CV_TTYPE_RF9000A_ prefix check. TP1X/Bespoke-class fridges use a
  CV_FDR_ prefix instead, which the old code didn't recognize -- the
  select existed but always read as unknown, and writing to it would have
  appended a duplicate CV_FDR_ flag rather than replacing the existing one
  (#26, #27; also closes #32).
- common: add energy_saved_kwh (x.com.samsung.da.cumulativeSavedPower) and
  power_energy_kwh (x.com.samsung.da.cumulativeConsumption) to the shared
  energy meter, plus fridge-only energy_last_month_kwh/energy_this_month_kwh
  (monthlyConsumption/thismonthlyConsumption) -- all self-gating on field
  presence (#26).
- by_type: add the WV consumer-model prefix (FlexWash twin washers, e.g.
  WV55M9600AW) to the by-model fallback map. These report no oneUiVersion
  and previously matched no prefix at all, so they fell all the way
  through to the unrecognized-device registry with zero capabilities
  bound (#19).
- washer: add a self-gating dry_level select to WASHER_SETTINGS for
  washer/dryer combo units, which carry a writable dryLevel field
  directly on /washer/vs/0 with no separate dryer resource or course
  (#22).

The reset-water-filter button and "ice type vs. two named icemakers"
requests from #26/#27 are left alone -- no write contract or exclusivity
behavior is evidenced in either dump, and both icemakers report On
simultaneously on the Bespoke unit, so synthesizing a single-select would
be a guess rather than a fix.

Adds scrubbed fixtures + goldens for FlexWash, a washer/dryer combo,
ARTIK051_REF_17K, and TP2X_REF_20K, plus unit tests for the new/changed
capabilities.
2026-07-22 06:11:15 +00:00
Marc Billow c0298d57d9 fix: normalize washer dosing-select codes; stop blocking the loop in diagnostics (#9)
Two fixes for issue #9 (WW90T634DHE washer):

- washer dosing selects: the four detergent/softener dosing selects read their
  current value from `<Prefix>LevelCtrl_<code>` (un-padded, e.g. "3") but their
  options from `Supported<Prefix>LevelCtrl_<hexpairs>` (zero-padded, e.g. "03").
  HA's SelectEntity renders a select "unknown" whenever current_option is not in
  options, so all four sat "unknown" (idle and running) even though every other
  select worked -- which is why it was only those four. Normalize the current
  value to the supported code with the same integer value so it matches an
  option (and its translation); convert back to the device's native un-padded
  format on write.

- diagnostics: pkg_version("smartthings-local") reads package metadata off disk
  (listdir + open + read_text), tripping HA's event-loop blocking-call detector.
  Offload it to the executor. Audited the rest of the package: config_flow's
  socket/crypto and every coordinator DTLS call are already offloaded via
  async_add_executor_job -- this was the only blocking call left on the loop.

Also documents air-conditioner support in the README (device table, capability
module list, platform list), missed when that support landed.

Updates the washer dosing tests to the corrected value/write format and adds a
current-option-is-a-valid-option regression; adds a diagnostics test asserting
the version lookup runs off the event loop.
2026-07-21 23:49:30 +00:00
Marc Billow 9264b912f9 feat: full dryer support + consistent laundry capability surface
First full dryer dump (issue #14, DV90BB5245AES1) surfaced 5 unbound
hrefs and an "incomplete capability coverage" repair. Handle them and,
while here, make the washer/dryer/dishwasher families consistent instead
of each carrying a bespoke variant of the same controls.

Dryer coverage:
- /power/0, /kidslock/0, /remotectrl/0: bind via the OCF-native + vendor
  fallback pairs (prefer the standard OCF resource, fall back to -vs).
- /buzzersound/vs/0: new Buzzer sound select.
- /course/vs/0: cycle select shared with washer/dishwasher; ignore the
  /st/dryercourse/vs/0 re-encoding (mirror of /st/washercourse/vs/0).

Consistency / de-duplication:
- Move generic OCF controls (power/kids-lock/remote-control fallback
  pairs, energy meter) into common.py; every registry uses them.
- Move shared laundry controls (buzzer, job-beginning-status, and the
  /course/vs/0 cycle-select machinery) into laundry.py; washer and
  dishwasher stop hand-rolling their own copies.
- Energy meter is now sentinel-aware everywhere: the dead '-500'
  instantaneousPower reading no longer shows a misleading 0 W (fixes it
  on dryers and dishwashers, matching the earlier washer fix).
- Job-beginning-status reads x.com.samsung.da.currentStatus, the field
  every dump actually carries; the dryer sensor was previously blank.

Adds a scrubbed dryer fixture, golden, and capability tests, plus an
.claude/skills/adding-device-support skill capturing the dump-reading,
OCF-vs-vendor, entity-taxonomy, and coverage workflow. Bumps to 0.6.0.
2026-07-21 01:15:12 +00:00
Marc Billow 35f76ce2df feat(washer): add label translations for detergent/softener dosing selects
Assumes the LevelCtrl code scheme is None/Low/Medium/High (00-03) on both
dispensers -- code 00 has no on-screen equivalent in the app's 3-choice
Faible/Moyen/Élevé picker, assumed to be what "Activation" off collapses
to -- and Level2Ctrl is Soft/Medium/Hard for detergent water hardness,
1x/2x/3x for softener concentration. detergent_quantity and
softener_quantity share one translation_key (same vocabulary), same
pattern as fridge.py's shared 'brightness_level' key.

Not cross-device verified: only one dump + screenshot set (issue #9) to go
on, and the softener concentration reading doesn't cleanly match its
screenshot (assumed to be a setting changed between dump and screenshots,
not a different code scheme -- see the comment in washer.py).
2026-07-18 18:24:10 +00:00
Marc Billow 2a6bbc9dfb fix(washer): stale idle progress%, add detergent/softener dosing entities (#9)
progress_percentage lacked the active-state gate already applied to
progress/cycle_active/finish_time, so it kept showing a stale device value
(e.g. 1%) while idle -- now zeroed the same way. Shared by dryer/dishwasher/
oven via operational.py's OPERATIONAL_STATE.

Also exposes detergent/softener auto-dispense quantity, water hardness/
concentration, and low-reservoir alarms from /course/vs/0's options array,
using the same decode/RMW helpers already used for course selection and
drum-clean tracking. Gated by exists_fn so washer models without these
fields (e.g. the existing test fixture) are unaffected.

Water consumption is unaffected -- common.WATER_METER is already wired
into the washer registry; this reporter's device just doesn't expose
/water/consumption/vs/0.
2026-07-18 18:15:41 +00:00
Marc Billow e875266405 fix(washer,fridge,oven): correct energy/temperature-unit bugs from issues #6/#7
Washer (#6): instantaneousPower is a dead sentinel ('-500') on every
TP1-class washer dump collected so far, and cumulativePower is absent
outright on at least one model. WASHER_ENERGY_METER now hides both
sensors instead of showing a misleading "0 W"/perpetual "unavailable".

Fridge (#7): temperature sensors/setpoints hardcoded '°F', ignoring the
unit each device actually reports per-reading -- fixed via a new
unit_fn hook read live from the resource. Also corrects
DEFROST_BLOCK_STATUS's polarity (DEFROST_BLOCK_ON means actively
defrosting, not "blocked", confirmed against live dumps) and adds
REFRIGERATION_FALLBACK for /refrigeration/0, closing the last unbound
href surfaced by issue #7's diagnostic dump.

Oven: applies the same live-unit-reading fix defensively to
OVEN_SETPOINT, which shares the same aggregate resource shape.
2026-07-15 11:41:21 -05:00
Marc Billow dd541b19a1 feat(washer): expose Drum Clean+ maintenance status
Adds cycles-until-due and last-cleaned sensors decoded from the same
options[] array the course selector already reads (DrumCleanProposal_N -
WashingTimes_N for cycles remaining, DrumCleanLog_<iso> for last-cleaned),
verified byte-for-byte against a live app screenshot ("Potreba cistenia po
37 cykloch" / "Naposledy cistene pred 10 dnami").
2026-07-11 20:18:28 -05:00
Marc Billow 211cf74296 feat(washer,dishwasher): live per-device cycle selector, localized names
Course selection is now a writable select entity sourced from each
device's own x.com.samsung.da.editCourseList (via a new options-as-callable
form on SelectDesc, reading the coordinator's full resource snapshot
instead of just the entity's own href), rather than a hardcoded course
table baked into Python. A MostUsed_ field on the same resource was
considered as a fallback but rejected after byte-level analysis showed it
doesn't reliably encode a course list. When a device never populates
editCourseList, the selector isn't created at all (exists_fn now takes
(rep, resources) to check a sibling href, matching the existing
match_fn(rep, resources) pattern).

Display names moved out of Python into strings.json/translations under
entity.select.{washer,dishwasher}_cycle.state.*, matching this
integration's existing translation_key convention (fridge.py's ice_type,
flex_zone_mode, etc.) instead of hardcoding English names in code.
2026-07-11 20:00:12 -05:00
Marc Billow 1b5e39ba46 feat(washer): prefer OCF-native power/kidslock/remotectrl hrefs, fall back to -vs 2026-07-11 12:35:47 -05:00
Marc Billow 2868938d37 feat(washer): add washer-specific capabilities 2026-07-11 12:31:20 -05:00