Commit Graph
3 Commits
Author SHA1 Message Date
Geunwon Mo 5c275753d4 Report whether the auto-clean cycle is running, and how far through
`/option/autoclean/vs/0` carries three fields and only `settingStatus` was read.
That one says the feature is enabled, which it is whether or not the unit is
drying right now, so nothing reported an actual cycle.

    settingStatus: On      <- the existing auto_clean switch
    status:        Stop    supportedStatus: [Start, Stop]
    progress:      0

Adds a binary sensor for `status` and a percentage sensor for `progress`.

Measured on a TP1X_DA-AC-CAC-01001, sampling the resource every eight seconds
across a cycle: `Start` with progress 98 while it ran, then `Stop` with progress 0
the moment it finished. The percentage matches the figure the appliance shows on
its own display, checked against 55% mid-run.

Golden state keys updated for the 18 fixtures that bind AUTO_CLEAN. The change is
additive — no key was removed from any of them.

Full suite passes (1070 tests, Python 3.13 via requirements-dev.txt).
2026-08-02 22:01:27 +09:00
Petr Divis f15ee7e563 Update golden fixtures for the new odor-controller entities
CI caught it: 8 pre-existing AC fixtures also carry genuine SmartCoolClean_/
ProgressSmartClean_ tokens in /mode/vs/0 (lnx_rac_heatpump, ara_ww_tp1_22,
windfree_oscillation, tp1x_rac_01001, fac_bora, fac_bora_2in1,
fac_bora_205_flat, cac), so odor_controller_active/odor_controller_progress
now correctly bind there too -- their golden state_keys lists just hadn't
been regenerated. Verified against the actual downloaded CI job log.
2026-07-31 16:39:08 +02:00
Marc Billow bd3ca80d3c review: address Opus code-review findings on this branch
- config_flow: the #192 port-rescue made the "every port refused" fast-fail
  permanently unreachable (PREFERRED_PROBE_PORTS is always non-empty and
  always rescued), so removed the dead branch instead of leaving it as
  misleading dead code. A dead host now fails via the handshake loop's own
  error, which carries the real per-port reason.
- oven._has_option: added the is_stub_rep carve-out cooktop.py's identical
  per-token exists_fn already has on the same kind of href, so a not-yet
  sub-polled /mode/vs/0 doesn't permanently exclude energy_saving/
  cooktop_on_alert before their first real fetch lands.
- airconditioner.ENERGY_METER_LEGACY: build via dataclasses.replace() like
  its ENERGY_METER_GENERIC sibling, instead of hand-copying href/poll_tier
  (which would silently drift if common.ENERGY_METER ever gains a field).
- Fixed two stale comments: is_legacy_board()'s docstring still listed
  Volume among tokens needing legacy-only gating, though 'beep' now applies
  unconditionally across board generations; and common.py's UNIVERSAL
  invariant comment didn't mention that airconditioner also now excludes
  ENERGY_METER from the wholesale bundle.
- #191 (CAC token): added the fixture/golden/capability-test coverage the
  AVT token in the same branch got, including an honestly-documented list
  of the ten hrefs this board generation doesn't cover yet.
- fridge.cooler_temperature_setpoint: dropped the hardcoded "N °C" state
  labels -- the resource's own unit field isn't necessarily Celsius on a
  different model reporting the same href, and the options themselves are
  already read live via options_field, so a static per-value label risked
  asserting the wrong unit for a future device sharing this capability.
- airconditioner._legacy_cumulative_power_kwh: parse with float (matching
  common.wh_to_kwh's own numeric parsing) instead of this module's
  integer-only _int, so a decimal-formatted reading doesn't raise.
- test_config_flow: the port-rescue test bound the real 49154 directly,
  which could collide with an actually-running service on some machine;
  now monkeypatches PREFERRED_PROBE_PORTS to an OS-assigned port instead.
- oven.py: consolidated six byte-for-byte-identical single-token options
  write_fns (lamp/sound/fast_preheat/natural_steam/energy_saving/
  cooktop_on_alert) into one _option_switch_write(prefix) factory.

845 tests passing (up from 841 -- 4 new CAC coverage tests).
2026-07-29 18:04:23 +00:00